    Introduction: The GDA 4360 is designed for use in safe area applications. It uses the latest laser semiconductor technology for detection of carbon dioxide. The sensor and electronics are one homogenous unit and must never be separated. It has an analog output which can be set to 4-20mA, 0-20mA, 0-10V or 0-5V.
  • Page 3: Installation

    Fit using the four fixing holes in the corners of the box. When drilling avoid any vibration of the sensor unit. The laser diode sensing unit is very sensitive. Do not expose the sensor to any mechanical shock. IT IS VERY IMPORTANT THAT THE GDA 4360 IS INSTALLED IN THE MOST UPRIGHT POSITION AGAINST A VERTICAL STRUCTURE...
  • Page 4: Operation

    2-4 minutes from the power being applied. During the 2-4 minute power up the current output of the GDA 4360 may reach the full scale of the set output. Ensure that this does not affect external equipment.
  • Page 5: Electrical Installation

    The 4-20mA O/P is to be connected to the 4-20mA input of the control board. Power and Protection Output Cover Plate Connector +24V DC 4-20mA O/P EARTH 0V DC Gas Detection (Australia) Pty Ltd Page 5 of 12 M-GDA-4360-V11-Rev 3...
  • Page 6: Output Operations

    Always observe anti static precautions. To change the output: 1. Isolate the GDA 4360 by removing the incoming power source connector (P1) from the rear of the board 2. Adjust jumper pins to the desired output configuration (see Table below) 3.
  • Page 7 The GDA 4360 is an auto calibrating device and under most cases will auto calibrate to new environment over time Functional testing may be carried out with a suitable test gas to ensure that the 4-20ma o/p corresponds with the gas level.
  • Page 8 18 and 17 of P3 for Manual Calibration Mode, return to this location only. Contact Gas Detection Australia for more information if calibration of sensor is required Gas Detection (Australia) Pty Ltd Page 8 of 12 M-GDA-4360-V11-Rev 3...
  • Page 9 Notes Gas Detection (Australia) Pty Ltd Page 9 of 12 M-GDA-4360-V11-Rev 3...
  • Page 10 Notes Gas Detection (Australia) Pty Ltd Page 10 of 12 M-GDA-4360-V11-Rev 3...
  • Page 11 Notes Thank You for Supporting Australian Manufactured Products Gas Detection (Australia) Pty Ltd Page 11 of 12 M-GDA-4360-V11-Rev 3...
  • Page 12 Gas Detection (Australia) Pty Ltd Page 12 of 12 M-GDA-4360-V11-Rev 3...

Table of Contents