THE DIRECT DRIVE BELT WINCH MUST:
BE CONNECTED IN ACCORDANCE WITH THE WIRING RULES OF THE COUNTRY IN
WHICH IT IS INSTALLED
NOT HAVE ENCLOSURES LEFT OPEN FOR EXTENDED PERIODS (EXCESS DUST WILL
VOID WARRANTY)

ELECTRICAL CONNECTION

The Direct Drive Cable Winch is designed to be operated with the Chore-Time reversing
starter controls. The internal connection diagram is shown below:
SINGLE PHASE ELECTRICAL CONNECTION
M
DOWN LIMIT
UP LIMIT
F
R
L1
L1
L2
E
MAINS
230V SUPPLY IN
ELECTRICAL CONNECTION
E
L2
9
Operation of the above control
panels is via a simple two position
control as shown below.
REVERSING
STARTER
WALL
CONTROL
THREE PHASE ELECTRICAL CONNECTION
MAINS
230V 3~
E
L1
L2
L3
L1
L2
L3
M
UP
STOP
DOWN
DOWN LIMIT
UP LIMIT
E