Summary of Contents for Loepfe WEFTMASTER FALCON-i
Page 1
WEFTMASTER FALCON-i ® Optical Yarn Defects Sensor Fitting and Service Manual Version 1.02 / 05.2014...
Page 3
Disclosures to any third party or reproduction of any kind – even in form of excerpts – as well as the use and/or disclosure of the contents without written approval from Loepfe Brothers Ltd., except for internal use, are prohibited.
Table of Contents Table of Contents General About this Manual Explanation of Symbols Liability Safety Responsibilities Personnel Requisitions Usage Installation and Start-up General Safety Connections Connection Diagram Mounting and Adjustment Possible Mounting Positions Service Safety Servicing Technical Data Spare Parts FALCON-i...
General General 1.1 About this Manual General 1.1.1 This manual assures a safe and efficient handling of the optical yarn defects sensor FALCON-i. For your safety in case of any insecurity, please contact your supplier. Obligation to Read 1.1.2 The personnel is obligated to read and understand these instructions, specifically the safety instructions, prior to all works.
Besides the contractual obligations terms of business and delivery by the supplier apply. Technical 1.3.3 Loepfe Brothers Ltd. herewith excludes liability for damages and accidents due to following occurrences: Modifications Unauthorized rebuilds or modifications of the optical yarn defects sensor ...
Installation Engineer and Service Engineer are qualified personnel being familiar with all safety checks, installation and service guidelines. Repair Technician is a qualified and trained employee of Loepfe Brothers Ltd. or a technician specifically appointed therefore by Loepfe Brothers Ltd.
Installation and Startup Installation and Startup 3.1 General Yarn guide Yarn guide ceramic Sensor Function button Yarn guide Digital display 3.2 Safety Installation and start-up may only be performed by authorized and trained personnel. Risk of injuries! Work on the running machine may lead to severe personal injury.
Installation and Startup 3.3 Connections Plug M8 male (front view) Plug M8 brown 24VDC 3.4 Connection Diagram male black PNP-Output (front view) (I = 2.7 mA constant) NPN-Output white (I Max. = 25 mA) brown 24VDC blue black PNP-Output 800ms (I = 2.7 mA constant) NPN-Output white...
Installation and Startup 3.5 Mounting and When mounting the optical yarn defects sensors FALCON-i, the following Adjustment must be observed: Do not position the equipment such that it is difficult to disconnect the M8 plug. The yarn should run as smoothly as possible through the sensor. ...
Service Service 4.1 Safety Servicing may only be performed by authorized and trained personnel. Risk of injuries! Work on the running machine may lead to severe personal injury. WARNING Z Stop the machine and wait until the machine has come to complete standstill.
Technical Data Technical Data Max power 500 mW Supply voltage 24 Vdc PNP output 2.7 mA ±8% constant current NPN output max. 25 mA Ambient temperature Operation 0 – 50 °C Ambient temperature Storage -20 °C – 85 °C Humidity 5 –...