Do you have a question about the Trans-CRS-162DZC and is the answer not in the manual?
Questions and answers
Summary of Contents for ICStation Trans-CRS-162DZC
Page 1
Electronic Scales DIY Kit 1. Introduction Multi-function electronic scales, not only to weigh, it can count, set the alarm and view the time. 2. Parameter Parameter Value Product name Multi function electronic scale Product model Trans--CRS--162DZC Maximum weighing 10kg...
4. Component listing Component Name PCB Marker Parameter Metal Film Resistor 4.7K 4.7K Crystal 11.0592M 11.0592MHz Crystal 32.768K 32.768KHz Ceramic Capacitor 30pf IC Socket DS1302 DIP-8 IC Socket AT24C02 DIP-8 IC Socket STC89C5XRC DIP-40 DS1302 DS1302 DIP-8 AT24C02 AT24C02...
Page 3
Screw M7*30 KCD1-11 Switch Power Socket USB Cable 5.5*2.1MM 5. Function 1>. Calendar, time, temperature display function. It will display Date,Time and Temperature after power on. It can set Date and Time by Set Button ‘A’ and ‘+’ button ‘B’ and ‘-’...
Money “M” will be calculated automatically. The unit price “P” can be accurate to 0.1. At this time, press the button ‘D’ to switch to the counting scale mode. 4>. Counting scale function “weighing scale” and “counting scale” switching by button “D”.
Page 5
2>. Setting of alarm clock In this mode of the interface, press the button A, the alarm switch ON/OFF, time, minutes, seconds cursor blinking in turn. Then it can be adjusted by buttons B and C. Press the button D, you can exit the “alarm settings interface” anytime to return to “calendar time interface”.
Page 6
The first line displays weight value, and the unit is KG. The second line displays D=single item weight, number of N= items. Keypad introduction: 1234567890 represents the number, the keyboard can set the value of P=, the value can be accurate to 0.1g.
7. Installation Steps Step 1: Install the PCB.Install 2pcs 4.7K resistor and 1pcs 11.0592MHz crystal and 1pcs 32.768KHz crystal in right place.
Page 8
Step 2: Install 2pcs 30pf capacitor,2pcs Right Angle 2P Male Pin for power and switch,1pcs Right Angle 8P Male Pin for keyboard,1pcs 3P Round Pin for DS18B20 sensor.
Page 9
Step 3: Install 2pcs DIP-8P IC socket and 1pcs DIP-40P IC socket.Pay attention to the installation direction.
Page 12
Step 6: Install 4pcs IC and battery.Pay attention to the installation direction.
Page 13
Step 7: Install 4P and 6P male pin for HX711 sensor module.Pay attention to the installation direction.
Page 14
Step 8: Install 16P male pin for LCD1602 display module.Pay attention to the installation direction. Step 9: Assemble PCB board,HX711 module,LCD1602,Pressure Sensor,and keyboard.Note the direction of the keyboard. Pressure Sensor and HX711 module connect type: Red==>E+ Green==>E- White==>A- Black==>A+...
Page 16
Step 10: Install brackets.Tear off the protective film.Install 6pcs Seat Cushion. There are transparent and black acrylic. The installation manual use black acrylic as an example.The same way of installation.
Page 18
Step 11: Install Pressure Sensor with 4pcs Acrylic Gasket by M7*30 screw fixed.Pay attention to the sensor installation direction.
Page 19
Step 12: Install cable to power socket and switch. Step 13: Install Power socket on side Acrylic board and fixed by nut.And then fixed it on base board.
Page 24
Step 16: Install LCD1602 on front acrylic.Pay attention to the sensor installation direction.Slightly fixed, do not install the screws too tight, otherwise it may damage the PCB or even LCD.
Page 25
Step 17: Install keyboard.Tear off the back of the film foil Paste on the acrylic And then connect it to PCB.Pay attention to the black mark.
Page 26
Step 18: Fixed front acrylic and connect wire as Step 9. Switch wire can be connect arbitrary. Step 19: Install Load-bearing acrylic with 4pcs Acrylic Gasket by M7*30 screw fixed.
Need help?
Do you have a question about the Trans-CRS-162DZC and is the answer not in the manual?
Questions and answers