Download Print this page

Advertisement

Quick Links

CH2165
FEATURES
Replaces conventional modems using the world
wide web for communication.
Transparent internet operations of Point-to-Point
Protocol (PPP), Password Authentication Protocol
(PAP) and Challenge Authentication Protocol
(CHAP) to connect to the Internet.
Built-in TCP/IP and SMTP to send emails, TCP/IP
and POP3 to retrieve and/or delete emails.
Send/Retrieve streaming email of unlimited length;
or pre-stored email up to 100K bytes in RAM.
Retrieve multiple messages or select individual
messages.
Once online CH2165 can stay online and send,
retrieve and/or delete email.
Programmable using serial interface.
Remote programming using browser to access
remote device.
Resident modem supports: V.90, V.34bis, V.34,
V.22bis, V.22A/B V.23, V.21, Bell 212A and 103,
(depending on model) and can be used in
conventional modem mode.
Error correcting: V.42 LAPM, MNP 2-4 and MNP10.
Automatic baud rate adaptability utilizing speed
sensing, flow control and data buffers.
Serial interface, V.24 (EIA 232-E), 5 volts.
NVRAM for stored modem (S-Registers) profiles.
®
Cermetek @T
AT-like Commands.
Built-in DAA with 1500 VAC RMS isolation 2122V
peak surge protection.
UL 1950 and CSA C22.2 950 (Third Edition) Listed,
reference UL File E104957.
FCC Part 68 Approved/Industry Canada CSA CS-
03 Part I approvable.
Pin-for-Pin compatible with CH2124/60 iModem
family and modem CH179X/2056 family.
+5 Volt operation.
Small size: 1.35" x 1.97" x 0.55" (nominal).
Use with any Non-proprietary commercial or private
ISP.
Cermetek's iModem Network ISP has 1000s of
local access numbers world wide.
1 year free trial subscription to iModem Network
ISP provided with each iModem.
2005 Cermetek Microelectronics, Inc.
HIGH SPEED INTERNET MODEM FAMILY
-
Send/Retrieve Email. Unlimited Email, V.90
INTRODUCTION
Direct machine-to-machine interaction represents the
next logical extension of the internet. Cermetek internet
modem (iModem) products are designed to exploit the
internet to facilitate the utilization of machine-to-
machine interactions.
easily be transferred between systems and can be
transmitted/retrieved at will. Internet email provides low
cost,
near
real
Replacing conventional modems and long distance
telephone lines with local access internet connections
reduces fixed asset and maintenance costs, limits
communication expenses and saves money.
USER FRIENDLY INTERFACE LAYER
All Cermetek iModem products contain a user friendly
interface layer that provides the user transparent
access to the internet. This interface layer, consisting
®
of various @T
macro commands, has the look and feel
of conventional modem AT commands. With the @T
macro commands the user can direct the iModem to
compose, edit/modify, send, retrieve and delete email
messages. Internet and email activity status is reported
via the iModem's V.24 (EIA 232-E) serial interface.
COMPARISON OF CH21XX iMODEM DEVICES
The CH2165 represents the next generation in internet
enabled devices. This product provides the user with
unsurpassed command and control capabilities. The
CH2165 communicates asynchronously with the host
controller (via the serial port) and the internet (via the
PSTN connection) simultaneously. Consequently, the
user can intersperse CH2165 specific management
commands
with
commands can be queued. The CH2165 will also send
or retrieve email messages of virtually unlimited length
by using streaming email techniques. The CH2165 is
ideal for applications where larger data transfers are
required and/or where large amounts of data must be
stored locally on the iModem device.
The CH2124/60 products are the first generation
internet enabled devices.
sending and retrieving modest amounts of data. Email
messages of approximately 125 ASCII characters in
length can be stored in internal Flash ROM for later
transmission.
The CH2124/60 products are ideal for very low cost
controller applications and in applications where limited
data transfer is required.
Page 1
Document No. 607-0017-01 Revision A (05/05)
Using email, information can
time
multi-path
communication.
internet
commands.
These products excel at
®
Further,

Advertisement

loading
Need help?

Need help?

Do you have a question about the CH2165 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cermetek CH2165

  • Page 1 Further, commands can be queued. The CH2165 will also send • FCC Part 68 Approved/Industry Canada CSA CS- or retrieve email messages of virtually unlimited length 03 Part I approvable. by using streaming email techniques. The CH2165 is •...
  • Page 2 A conceptual representation of the iModem in an embedded environment is presented in Figure 1. As The total CH2165 RAM memory available to the user is can be seen in this figure, the iModem requires the approximately 100K bytes. For messages that need to...
  • Page 3 POP, log on to the internet, authenticate and verify the streaming messages obtained in real-time from the user ID and password, and either sends or retrieves CH2165’s DTE serial I/O port. In either case, multiple email depending on the command received. See Table email destination addresses are allowed.
  • Page 4 PSTN INTERFACE V-24 Ring EIA-232-E or UART MODEM INTERFACE Figure 2. Functional Block Diagram of Cermetek CH2165 iModem Products. When using pre-stored messages in resident memory, iModem to send four successive PING commands user responsible message memory directly to the internet host. Responses from the host management and utilization.
  • Page 5: Key Feature

    The internal modem is used to and ringer equivalent. The PSTN line interface is establish a data connection with the ISP. The CH2165 UL1950 and CSA listed. Consequently, the iModem contains a V.90 internal modem. The internal modem family of products satisfies U.S. and Canadian...
  • Page 6 Delete filename, n, from RAM memory. ----- @T[ML][?=n] Displays file name and size of all temporary (i.e., RAM memory) files and all static (i.e., FLASH memory) files stored on the CH2165. Allowable values: Only STATIC memory files displayed. Only RAM memory files displayed.
  • Page 7 By default, if no value is specified, the CH2165 will automatically determine the maximum baud rate supported by the PSTN connection. This is referred to as auto- bauding. The @TBC command is currently NOT ENABLED. The CH2165 will autobaud.
  • Page 8 Z Display factory default parameter restore command syntax. Server Addresses @T[SS][=n] @T[S][?] Set SMTP server symbolic name, n. This symbolic name is used by the CH2165 to determine the SMTP server address. @T[SM][=n] @T[S][?] Set POP3 server symbolic name, n. This symbolic name is used by the CH2165 to determine the POP3 server address.
  • Page 9 When operating as an analog modem, all supported Hayes AT commands can be executed. All @T commands are non-functional while the CH2165 is operating as an analog modem. ----- When operating as an analog modem, used to change from Data Entry to Command Mode.
  • Page 10: Fcc Registration

    In addition to restriction notification, the FCC requires to allow the users to make any changes necessary to that Cermetek make all repairs to all products in the maintain uninterrupted service. iModem family.
  • Page 11: Data Set Ready

    REQUEST TO SEND. Active Low. Used for flow control. Should be tied Low when using SEND pin and when using @T commands for CH2160 only. DO NOT CONNECT for CH2124. 2005 Cermetek Microelectronics, Inc. Page 11 Document No. 607-0017-01 Revision A (05/05)
  • Page 12 B. In most environments, 2 terminal surge also survive FCC Part 68 surge testing. Refer to suppressors are adequate. For severe Cermetek Application Note #126, Supplemental environments, use an external 3 terminal PSTN Line Protection, for more details. Refer to device with an earth ground.
  • Page 13 0.01µf Output Impedance 10ohm Output Voltage 2.5 ± 1.6V D.C. Offset <20mV Table 4. Summary CH2165 iModem Family of Products. Model Summary of Features Operating Temperature CH2165 Send and Retrieve Streaming Email. Email Send Control Pin 0°C to 70°C Full Function, V.90, 56Kbps, FCC Part 68 Approved, UL 1950 listed.
  • Page 14 Minimum Reset Pulse µsec If user supplied Note: 1. All CH2165 iModem devices re-load operating firmware upon reset and then perform an internal self-check. The CH2165 will not respond to commands issued during this sequence. Figure 8. Physical Dimensions and Pin Functions for CH21XX Product Family.
  • Page 15 Cermetek reserves the right to make changes in specifications at any time and without notice. The information furnished by Cermetek in this publication is believed to be accurate and reliable. However, Cermetek assumes no responsibility for its use, or for any infringements of patents or other rights of third parties resulting from its use.