Advertisement

Quick Links

Instructions for Use
MODEL 7070 NasoNeb Sinus Therapy System
MODEL 7080 NasoNeb Sinus Therapy System Supply Kit
NasoNeb, Inc.
153 Industrial Blvd Plattsburgh, NY 12901 USA
Telephone: +1-866-960-9833
www.nasoneb.com
European English - EU

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7070 and is the answer not in the manual?

Questions and answers

Summary of Contents for NASONEB 7070

  • Page 1 Instructions for Use MODEL 7070 NasoNeb Sinus Therapy System MODEL 7080 NasoNeb Sinus Therapy System Supply Kit NasoNeb, Inc. 153 Industrial Blvd Plattsburgh, NY 12901 USA Telephone: +1-866-960-9833 www.nasoneb.com European English - EU...
  • Page 2: Table Of Contents

    Caution – The NasoNeb Sinus Therapy System is designed for single person use. Do not share the NasoNeb Sinus Therapy System with others. Doing so risks the spread of infection. Intended Use: The NasoNeb Sinus Therapy System is designed to deliver...
  • Page 3: Important Safeguards

    • Use only with NasoNeb-brand accessories • Never drop or insert any object into any opening or hose • Do not use outdoors. This NasoNeb Sinus Therapy System is for indoor use only SYSTEM COMPONENTS NasoNeb Compressor...
  • Page 4: Set Up And Operation

    SET UP AND OPERATION Follow these simple steps to prepare and operate the NasoNeb Sinus Therapy System. SET UP Unpack the NasoNeb Sinus Therapy System and assemble by following these steps: 1. Unpack the Supply Tubing and Filters 2. Set the Filters aside for safekeeping 3.
  • Page 5 SET UP AND OPERATION HOW TO USE 1. Place half of the medicine into the Cup Assembly 2. Place the Cup Assembly into one nostril, aim it straight in or slightly away from the septum (the middle of your nose that divides your nostrils) 3.
  • Page 6: Cleaning And Storage

    6. You may rinse the Cup and Insert with hydrogen peroxide or isopropyl alcohol Replace Supply Tubing and Cup Assembly with a Model 7080 NasoNeb Sinus Therapy System Supply Kit every 6-12 months or every 730 cleaning cycles. Store the NasoNeb Sinus Therapy System in a dry place.
  • Page 7: Troubleshooting

    TROUBLESHOOTING Problem Possible Cause Resolution No mist is created Insert not in place Ensure Insert is in place No fluid in Cup Check for fluid in Cup Supply Tubing not connected Check Supply Tubing to device or Compressor connections Compressor Compressor not Plug Compressor into doesn’t turn on...
  • Page 8: Specifications

    SPECIFICATIONS Specifications and appearance are subject to change without notice. Components may be substituted at the will of NasoNeb, Inc. NASONEB Compressor Electrical DC 12V 1.5A, 180 VA Sound Pressure 55 dB Free flow 6 l/min nominal Compressor Pressure Range ≥200 kPa (≥29 psi)
  • Page 9: Guidance And Manufacturers Declaration

    – for all EQUIPMENT AND SYSTEMS 1 Guidance and manufacturer’s declaration – electromagnetic emission 2 The NasoNeb Compressor is intended for use in the electromagnetic environment specified below. The customer or the user of NasoNeb Compressor should assure that it is used in such an environment.
  • Page 10 Guidance and manufacturer’s declaration – electromagnetic immunity The NasoNeb Compressor is intended for use in the electromagnetic environment specified below. The customer or the user of the NasoNeb Compressor should assure that it is used in such an environment. Immunity Test...
  • Page 11 To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the NasoNeb Compressor is used exceeds the applicable RF compliance level above, the NasoNeb Compressor should be observed to verify normal operation.
  • Page 12 RF communications equipment and the NasoNeb Compressor The NasoNeb Compressor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the NasoNeb Compressor can help prevent electromagnetic interference by maintaining a minimum distance between...
  • Page 13: Warranty

    Any defective parts or assembly will be repaired or replaced, at the sole discretion of NasoNeb, Inc. if the unit has not been misused or tampered with during the Warranty Period. Repair or replacement of defective parts shall not extend the term of any applicable warranty and the original term of such warranty shall remain in effect.
  • Page 16 +1-866-565-1893 www.nasoneb.com MDSS GmbH Schiffgraben 41 30175 Hannover Germany Tel.: +49 511 6262 8630 Fax: +49 511 6262 8633 NasoNeb and the NasoNeb Logo are trademarks of NasoNeb, Inc. Manufactured in the USA Date of revision 2021/11/03 Reference Number 300-532105-01...

This manual is also suitable for:

7080

Table of Contents