Advertisement

Quick Links

Aseptika Limited (Activ8rlives), Suite 5, SiTwo (formerly LDH House,
UK Dist
Parsons Green, St Ives, Cambridgeshire, PE27 4AA,
United Kingdom
Guangdong Transtek Medical Electronics Co., Ltd.
Zone A, No.105, Dongli Road, Torch Development District,
528437, Zhongshan,Guangdong, China
Medical Device Safety Service GmbH
EC REP
Schifgraben 41, 30175 Hannover, Germany
MDSS-UK RP Ltd., 6 Wilmslow Road, Rusholme,
UK RP
Manchester, M14 5TP, United Kingdom
ASL TF-020 MAN_IFU016 Blood Pressure3
Connected Monitor (V2.0)
Last Updated: 13.02.2022
Upper-arm Cuff 22 - 42cm
(8¾-16½")
Instructions for Use

Advertisement

Table of Contents
loading

Summary of Contents for Activ8rlives Blood Pressure3 Monitor

  • Page 1 Upper-arm Cuff 22 - 42cm (8¾-16½”) Instructions for Use Aseptika Limited (Activ8rlives), Suite 5, SiTwo (formerly LDH House, UK Dist Parsons Green, St Ives, Cambridgeshire, PE27 4AA, United Kingdom Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105, Dongli Road, Torch Development District,...
  • Page 2: General Description

    General Description Safety Information Thank you for selecting the Activ8rlives Blood Pressure3 Read before Use Type BF applied parts Connected Monitor. The monitor measures blood pressure (Systolic/Diastolic), heart beat (bpm) and Manufacturer includes irregular heartbeat detection (IHD). Electrical waste products...
  • Page 3 Medical Team. Do not • allow the device to experience excessive forces, shocks, dust, rely on the Activ8rlives Blood Pressure3 Connected Monitor to lint, direct sunlight, temperature and humidity over the range diagnose blood pressure and irregular heartbeat conditions. This specified;...
  • Page 4: List Of Compatible Devices

    LTHC-related symptoms, refer to your Care Plan provided by this device, please report this to Aseptika Limited your medical team and follow the instructions carefully. If you (Activ8rlives) and the Competent Authorities of the country in continue to have symptoms, consult your medical team. which you reside.
  • Page 5: Monitor Components

    • Replace battery cover. Replace batteries when: List shows. The display is dim. Blood Pressure3 Monitor Upper-arm Cuff (22cm-42cm) The display does not light up. CAUTION Do not use new and used batteries together. Do not use different types of batteries together.
  • Page 6 Tips Before Your Reading Tip 8: Keep still for the duration of measurement. Moving, talking, eating, drinking or any other activity will produce errors. Tip 1: Try to take your blood pressure at the same time each day. It will vary throughout the day. Doing this in Tip 9: Use the same arm each time.
  • Page 7 What are systolic pressure and diastolic pressure? Why does blood pressure fluctuate When ventricles contract and pump throughout day? blood out of the heart, the blood Systolic Diastolic pressure reaches its maximum value in Individual blood pressure varies blood discharging blood entering the cycle, which is called systolic throughout the day.
  • Page 8: Lcd Display Signal

    LCD display signal Maintenance To obtain the best performance from your device, follow the maintenance instructions below. Do not submerse in water, clean Store, use in dry place and avoid direct sun. with damp cloth. Avoid dusty, humid and unstable SYMBOL DESCRIPTION EXPLANATION...
  • Page 9 Battery powered mode: 6V DC 4*AAA asked questions for problems you may encounter with the batteries. AC Adapter powered mode: Power supply 1A (not included) Activ8rlives Blood Pressure3 Connected Monitor (P109). Display mode Blue LCD with backlight V.A.60 × 40.5mm Problem Symptom...
  • Page 10: Emc Guidance

    EMC Guidance Table 2 The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments. Guidance and manufacturer’s declaration – electromagnetic Immunity Warning: Do not be near the active HF surgical equipment and the RF shielded room of an ME IEC 60601-1-2 system for magnetic resonance imaging, where the intensity of EM disturbances is high.
  • Page 11: Complied Standards List

    Complied Standards List Table 3 Guidance and manufacturer’s declaration - electromagnetic Immunity EN ISO 14971:2012/ISO 14971:2007 Medical devices - Risk management Application of risk management to medical devices Compliance Radiated RF Test Band Service Modulation Maximum Distance 60601-1-2 level IEC61000-4-3 Frequency (MHz) Power...
  • Page 12: Contact Information

    Authorised Component Please use the Activ8rlives Need to contact Customer Support? authorised adapter (Not included). We take Customer Support seriously so we provide 7-days-a-week support for you, between 09:00-18:00. Adapter Type: BLJ06L060100P-B You can contact us: Input: 100~240V, 50~60Hz, 0.2A Max Output:...

Table of Contents