Install the Voltage Guard on a solid surface. Use reliable
terminals to avoid bad connections. Fasten the bolts tightly
but not overtighten them. Connect the Voltage Guard
according the wiring diagram as shown below. Connect
the ground terminal via a 'faston' connector with the
ground of the installation. Make the connection between
the
terminal and the + of the system. Connect the
consumers to the
terminal.
Make sure the wiring has the appropriate size and the
is fused with the right value!!!
Make the next connections when the main switch function
will be used. Connect one side of the switch contact to the
switch connection on the Voltage Guard. And connect the
other side to the ground (-) of the installation.
Safety measures
Use wiring with the appropriate size. Use the right fuse in
wiring.
Mount the Voltage Guard in a dry and ventilated place.
Never use the Voltage Guard at locations where there is
danger of gas or (dust)explosion.
Make the connections and protections according the
locally applicable regulations.
Check once a year the wiring and connections and repair
the faults.
The manufacturer can not be held responsible for damage
resulting from the use of the Voltage Guard.
EN / WBI-VG 200 / February 2012
Technical specifications
Current (continue / intermitted) : 150 / 200 A DC
System voltage
Input voltage range
Measurements (l x b x h)
Weight
Low voltage setting 12V
High voltage setting 12 V
Low voltage setting 24V
High voltage setting 24 V
The guaranty period is one year.
INSTALLATION
: 12 or 24 DC
: 8 - 31 V DC
: 145mm x 92mm x 85mm
: 580 gram
: 9 - 12 V DC
: 15,5 V DC
: 18 - 24 V DC
: 31 V DC