Advertisement

1

Advertisement

Table of Contents
loading

Summary of Contents for CGOLDENWALL ST-135

  • Page 2 Preface Welcome to use CGOLDENWALL steam generator and select one of ST-135 controller to control it. The steam generator, which has the reasonable design, stable function and beautiful appearance, uses the international advanced technology. It equips with special room body to form the complete set of sauna, which can relax people’s muscle,...
  • Page 3: Table Of Contents

    CONTENTS Parameters....................4 Instructions for Installation..............5 Steam Generator Location..............6 Water Inlet pipe..................8 Steam Outlet pipe.................9 Drain pipe and Auto drain valve............9 Steam nozzle..................11 Wiring Connection................12 Controller Install Guide..............16 Temperature Probe Install..............17 Start the steam generator..............18 Controller Operation Guide..............18 Maintenance operation guidance............20 Troubleshooting Guidance ..............22...
  • Page 4: Parameters

    220/2 17.5×6.5×15.6 220/2 17.5×6.5×15.6 10.5 220/2 19.7×7.9×20.5 380/3 19.7×7.9×20.5 380/3 19.7×7.9×20.5 380/3 19.7×7.9×20.5 2, the basic parameters of controllers and the size in table 2 Table 2 Model time Range of Size(length*width*height) temperature (mm) (minute) ST-135 100×100×40 95 - 131℉...
  • Page 5: Instructions For Installation

    Instructions for Installation The steam generator has been carefully assembled and tested, please fix in accordance with national laws and regulations. And be fixed by the people who has local or national plumber certificate. Turn off all the power in fixing, and make sure that if the type applies for the shower room.
  • Page 6: Steam Generator Location

    Steam Generator Location 1, the steam generator should be fixed in the wall or on the floor firmly, Select a location as near as practical to the shower room. Typical locations include: closet, vanity cabinet, climate controlled attic or basement. In the process of fixing, install the machine on a vertical wall, release the two screws on the cover, move the cover and then fix the machine using the holes on the top right and left.
  • Page 7 attic floor(insulated) suitable for installation Controller (suitable be installed outdoors) steam jet under the wash basin Controller (suitable (suitable for installation) be installed outdoors) closet steam generator (suitable for installation) basement (suitable for installation)
  • Page 8: Water Inlet Pipe

    Pipe installation Water source pipe and steam pipe should be installed in accordance with national laws and regulations. The installation should be done before sealing walls. 1, Water inlet pipe--the water inlet pipe is connected with the DN15 pipe (1/2 NPT). And a DN15 metal hose is connected to the water inlet and water supply valve of the machine.
  • Page 9: Steam Outlet Pipe

    2, Steam outlet pipe---steam pipe should use copper pipe longer than DN15 (ferrous metal and galvanized pipe was not allowed to use for it can make the shower room rust and discolor). The length of steam pipe was no more than 3 meters. It should be used for keeping warm if it is longer than 3 meters.
  • Page 10 drain is automatically turned on after the controller is turned off for about 15 minutes, but it must be ensured that the main power supply is not turned off.  1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes.
  • Page 11: Steam Nozzle

    4, Steam nozzle---in the shower room, put the decorative pipe over the steam pipe and smear the sealant, and then spin on the nozzle. Do not put forth strength excessively in case of damaging the decorative pipe and steam nozzle. Make sure nozzle point to the floor. Note: The steam nozzle should be 30cm high from the ground or 20cm high from the edge of the bathtub.
  • Page 12: Wiring Connection

    Keep the pipe dredged and clean before connect the last pipe. ·Do not install blocking valve in the steam pipe. The blocks or ‘U’ shaped channel may result condensate and prevent the circulating. The steam pipe should be a little declining so the condensate can flow to each side.
  • Page 13 TO AVOID EQUIPMENT DAMAGE, DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS!!! Wiring diagram  If you are in 110V countries, like America, you need to connect to TWO DIFFERENT 110V live wires(L1 and L2). NO neutral wire is required. L1, L2, Ground to be field wired...
  • Page 14  If you are in other 220V countries, you need to connect to one 220V live wire and one neutral wire (L and N). For both, a ground wire is needed. L1, N1, Ground to be field wired When installing the steam generator, please note that it has been carefully assembled and tested by our technician.
  • Page 15 principal 210--8). 3, select the proper electric circuit trace according to the local request. Please install the socket near the steam generator if it is necessary. The current load of plug and socket should be more than 250V. After the sealing wall, the machine and the controller’s wiring can be done. 4, release the screw and open the top.
  • Page 16: Controller Install Guide

    32 feet. The steam generator and control must be located accordingly. 2, ST-135 controller’s Installation—controller can be installed indoor or outdoor of the steam .For convenient use, please install it far from the earth 1500mm.
  • Page 17: Temperature Probe Install

    wall. (note; 1, control line muse be installed inside the ray tube for maintaining. 2, the double-sided adhesive on the controller’s back can not work for fixed function and glass glue should be used to fix.) Temperature probe installation The temperature probe induces the temperature in the shower room. Its installation height is 1.5m and it should be fixed inside the shower room by screws.
  • Page 18: Start The Steam Generator

    Our company will not take the responsibility if it is damaged by wet. ·The double-sided adhesive on ST-135 the controller’s back can not work for fixed function and glass glue should be used to fix.
  • Page 19 Press the setting key again or quit the setting status in 15s after the proper temperature. The setting temperature range is from 95 ℉ to 131℉. Heating indicator Temperature display light Heat indicator light On/off key Temperature setting key START ON/OFF TEMP Digital by/down key ST-135 Controller...
  • Page 20: Maintenance Operation Guidance

    Steam generator’s maintenance Steam generator’s maintenance 1, check steam generator, steam nozzle, parts and pipelines regularly to prevent the damage coursed by steam and leak. 2, the machine equips with auto drain valve for discharging precipitate in the generator. The work is done every month or even more frequently depending on water quality or generator’s using.
  • Page 21 up hose, release two screws and remove the solenoid valve. The installation of solenoid valve and hose is opposite with above. 4, change water level probe; turn off the power, open the front cover, and pay attention to the water level that blue and write water level probe point to.
  • Page 22: Troubleshooting Guidance

    Troubleshooting Guidance The machine does not contain the parts that the users can operate. The maintenance must be done by professionals who have certification. Please contact with seller if more services or authorized services are needed. Failure 1: Controller displays "00" If the controller displays "00", it is because the temperature probe is not connected well, or the temperature probe is damaged.
  • Page 23 Failure 3 : Indicator lights on circuit board excludes the troubles Red light: power. if the red light are not on, the machine is not receiving power, please kindly check the wiring connecting and power Green light: working. If the green light are not on, the machine is not receiving working Yellow light: heating.

Table of Contents