L
EOS 9 Inground
UX
LED INGROUND FLOOD FOR ARCHITECTURAL LIGHTING
Important
• LuxEOS luminaires must be installed by a qualified electrician.
• Installation must be carried out in accordance with local and/or national
electrical installation codes of practice.
• Isolate the mains supply during installation and whenever subsequently
disconnecting or reconnecting the luminaire or luminaire driver.
WIRING DETAILS
Typical Connections
LuxEOS IG 9 luminaire
LuxEOS IG 9 driver with
QuickLink + input
& X-Lok output connectors
QuickLink + IP68
connector (M)
Power & DMX Data In
IP68 Connection box (potted)
Provided by others
1m Cable - QuickLink + (F) to open ends
(LUXIHWX.XL01.XX.NONE.XXX.XX.XX)
The QuickLink + (F) to open end combined power and DMX cable (LUXIHWX.XL01.XX.NONE.XXX.XX.XX) is necessary as part of the first fix solution to enable connections to existing
wiring. The bare end of the cable should be connected as shown above using an IP68 installation connection box, care should be taken to separate the mains and control cabling,
the female QuickLink + connector can then be plugged into the LuxEOS 9 inground driver to provide power and DMX-RDM control data.
If the driver / cables are installed at an earlier point to the luminaire or if the luminaire is removed, then the power must be disconnected and the supplied blanking cap be fitted
to the QuickLink + connector to prevent any ingress to the terminals.
P U L S A R
Part of DW Windsor Ltd, Pindar Road, Hoddesdon, Hertfordshire, EN11 0DX, UK
www.dwwindsor.com/pulsar | info@dwwindsor.com | +44 (0)1992 474600
INSTALLATION
X-Lok IP68
Connector
QuickLink + IP68
connector (F)
1m Cable
QuickLink + (F) to open ends
Power & DMX Data Link
VIVID COLOUR & TUNABLE WHITE
• Ensure the correct polarity when wiring, if in any doubt please contact Pulsar.
Any damage caused to the luminaire or luminaire driver by electrical
misconnection will void the warranty.
• Unless authorised by Pulsar, field repairs or opening of the luminaire or
luminaire driver will void the warranty.
1m Cable
QuickLink + (F) to open ends
Power & DMX Data Link
IP68 Connection box (potted)
Provided by others
Connection details
Green - Earth
White - Neutral
Black - Live
Data - Screen
White - Data + In
Green - Data - In
Blue - Data + Out
120Ω termination resistor must be
Red - Data - Out
fitted if the luminaire is last in the DMX data line
1m Cable
QuickLink + (F) to open ends
IP68 Connection box (potted)
Provided by others
7650 - L9 IG - INST
1 of 10
Need help?
Do you have a question about the LuxEOS 9 and is the answer not in the manual?
Questions and answers