scigiene GEN 2 User Manual

scigiene GEN 2 User Manual

4g industrial cellular gateway

Advertisement

Quick Links

GEN 2 4G Industrial Cellular
Gateway
USER GUIDE
IMPORTANT!
For best results, please wait to power on your GEN 2 4G Cellular Gateway until after you have
created an Scigiene Premiere account and added the gateway and sensors to your new 4G Cellular
network.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GEN 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for scigiene GEN 2

  • Page 1 GEN 2 4G Industrial Cellular Gateway USER GUIDE IMPORTANT! For best results, please wait to power on your GEN 2 4G Cellular Gateway until after you have created an Scigiene Premiere account and added the gateway and sensors to your new 4G Cellular network.
  • Page 2: Table Of Contents

    Table of Contents I. ABOUT THE GEN 2 4G Cellular GATEWAY GEN 2 4G Cellular GATEWAY FEATURES EXAMPLE APPLICATIONS II. HOW YOUR GATEWAY WORKS III. GATEWAY SECURITY SENSOR COMMUNICATION DATA SECURITY ON THE GATEWAY SERVER COMMUNICATION SECURITY IV. GATEWAY REGISTRATION REGISTERING THE GEN 2 4G Cellular GATEWAY V.
  • Page 3: About The Gen 2 4G Cellular Gateway

    The Scigiene GEN 2” 4G Cellular Gateway uses 4G LTE CAT-M1/NB2 cellular technology to control GEN 2 Wireless Sensor settings without additional IT infrastructure. All you need is a power source and the Scigiene Premiere cloud platform to monitor your environment and equipment using Scigiene’s industry- leading wireless devices.
  • Page 4: How Your Gateway Works

    The gateway will store data it received from sensors until its next Heartbeat. The GEN 2 4G Cellular Gateway is a cellular (LTE-M or CAT-M1) gateway. It uses its connection to relay data received from sensors to Scigiene Premiere cloud-based software.
  • Page 5: Gateway Security

    II. GATEWAY SECURITY The GEN 2 4G Cellular Gateway is designed and built to manage data from sensors monitoring your environment and equipment securely. The same methods used by financial institutions to transmit data are also used in Scigiene security infrastructure. The 4G Cellular Gateway’s security features tamper-proof network interfaces, data encryption, and bank-grade security.
  • Page 6: Gateway Registration

    REGISTERING THE GEN 2 4G Cellular GATEWAY You will need to enter the Device ID and the Security Code (SC) from the GEN 2 4G Cellular Gateway in the corresponding text boxes. Use the camera on your smartphone to scan the QR code on your gateway.
  • Page 7: Using The 4G Cellular Gateway

    II. USING THE 4G Cellular GATEWAY USING THE 4G Cellular GATEWAY 1. Attach the cellular and GEN 2 antennas to the back of the gateway at the locations depicted in Figure 3. 2. Plug the power supply cord into an outlet.
  • Page 8: Cellular Gateway Settings

    Subsequent connections are typically faster. 4G Cellular GATEWAY SETTINGS (SCIGIENE PREMIERE) The 4G Cellular Gateway will receive data from all sensors assigned to the network and within range, then return this data to the server in a series of Heartbeats.
  • Page 9 Ethernet Settings (future capability) Choose the Ethernet Settings tab under Settings to open up the configuration page for the Local Area Network (LAN). The LAN is used for local configuration options when server connectivity is not possible. This page includes the ability to switch your network Internet Protocol (IP) Address from DHCP assigned to Static.
  • Page 10 Cellular Settings The Global System for Mobile Communications utilizes a 15-digit IMSI (International Mobile Subscriber Identity) number as the primary mode to identify the country, mobile network, and subscriber. It is formatted as MCC-MNC-MSIN. MCC is the Mobile Country Code. MNC is the Mobile Network Code attached to the cellular network.
  • Page 11 Figure 9 Carrier APN is provided by the carrier and enables access to the cellular carrier's network and public or private Internet access. SIM Authentication Type: A minority of APNs are set up with a username and password used to create authenticated network sessions. Where this is not the case, the default of None may be selected in the drop-down menu.
  • Page 12 Commands Choose the Commands tab located just under Settings to access the Commands page. The Auto Reset field is the amount of time in hours that the Local Interface will automatically reboot. Setting this to 0 will disable the feature. The maximum setting is 8760 hours.
  • Page 13: Using The Local Interface

    III. USING THE LOCAL INTERFACE If using Scigiene Premiere is not an option, you can set up your gateway settings through the local interface. • Connect the gateway Ethernet cord by one of the following methods: o AUTO-IP Method: Plug the cable directly into a PC and disable other networking interfaces.
  • Page 14 Cellular Network Status Link - Defines whether your Cellular Network is connected. IMEI - (International Mobile Equipment Identity) is a number exclusive to your LTE International Gateway to identify the gateway to the cell tower. The Global System for Mobile Communications network stores the IMEI numbers in their database (EIR - Equipment Identity Register) containing all valid cellular equipment.
  • Page 15 Figure 13 GENERAL CONFIGURATIONS Gateway Settings Power Mode - As discussed above, this setting allows the user to choose Standard, which keeps lights and cellular transmission active when plugged into an outlet, or when on battery power, powers down lights and the cellular connection between communications. The user may also choose Force Low Power, so the gateway always powers down the lights and the cellular connection when not talking to the server, or Force High Power, so the gateway always keeps the lights and cellular transmission active.
  • Page 16: Ethernet Network Settings

    The gateway must be submitted to a factory reboot, or reconfigured in Scigiene Premiere, so that the HTTP Interface can change settings again during the timeout window. The timeout window is refreshed each time the Interface page is refreshed or every time the gateway restarts the HTTP interface.
  • Page 17: Cellular Network

    CELLULAR NETWORK The Cellular Network Configuration holds a drop-down menu to select your cell Carrier Preferences, concerning the APN and the active bands enabled for Cat-M1/LTE Cat-M/LTE-M and NB-4G Cellular communication with a cellular tower. In most situations, Auto Configuration should be selected to allow the preconfigured SIM card shipped with the 4G Cellular Gateway to handle configuration of the APN and active bands.
  • Page 19: Wireless Network

    This is an alternative way to add devices to communicate with your gateway. Any wireless device added here will continue to display on your Scigiene Premiere account. However, once you have added one or more devices to your gateway’s network here, the network should be reformed to inform the gateway.
  • Page 20: Miscellaneous

    Reform Network Selecting the Reform Now button will trigger the gateway to remove all of the sensors from the internal whitelist, and then request a new sensor list from the server. This command will force all of the sensors to reinitialize their connection with the gateway. Reforming the network cleans up communication when multiple networks are in range of each other so they are all in sync.
  • Page 21: Support

    If any software or firmware incorporated in any Product fails to conform to the warranty set forth in this section, Scigiene shall provide a bug fix or software patch correcting such non- conformance within a reasonable period after Scigiene receives from Customer (i) notice of such non- conformance, and (ii) sufficient information regarding such non-conformance so as to permit Scigiene to create such bug fix or software patch.
  • Page 22 Please visit Scigiene.com/policy/returns/ for Scigiene's return policy and instructions. (c ) Scigiene's sole obligation under the Warranty described or set forth here shall be to repair or replace non-conforming products as set forth in the immediately preceding paragraph, or to refund the documented purchase price for non-conforming Products to Customer.
  • Page 23 All GEN 2 Wireless Sensors and Gateways Contain FCC ID: ZTL-G2SC1. Antennas GEN 2 devices have been designed to operate with an approved antenna listed below, and having a maximum gain of 14 dBi. Antennas having a gain greater than 14 dBi are strictly prohibited for use with this device.
  • Page 24: Safety Information

    SAR regulation. Additional Information and Support For additional information or more detailed instructions on how to use your Scigiene Sensors or Scigiene Premiere, please visit us on the web at www.scigiene.com...