Electrical Data; G Electrical Characteristics - Sanyo CH1822 Service Manual

Split system air conditioner
Hide thumbs Also See for CH1822:
Table of Contents

Advertisement

7. ELECTRICAL DATA

G Electrical Characteristics

KHS1822 / CH1822
Performance at
230/208V – 1ø – 60Hz
Rating
Cooling
Conditions
Rating
Heating
Conditions
Locked-Rotor Amperes
Remarks: Rating conditions are:
Cooling: Outside air temperature 95°F DB/75°F WB
Indoor unit entering air temperature 80°F DB/67°F WB
Heating: Outside air temperature 47°F DB/43°F WB
Indoor unit entering air temperature 70°F WB
Indoor Unit
Fan Motor
Max. Heat
A
0.40 / 0.40
W
90 / 81
A
0.40 / 0.40
7.8 / 7.1
W
90 / 81
1,800 / 1,470
A
0.45 / 0.40
Outdoor Unit
Fan Motor
Compressor
0.47 / 0.47
7.13 / 7.73
105 / 95
1,595 / 1,564
0.47 / 0.47
7.13 / 7.73
105 / 95
1.595 / 1.574
0.71 / 0.64
52
9
WM – 700796
Complete Unit
Heat-pump
Max. Heat
8.0 / 8.6
1,790 / 1,740
8.0 / 8.6
15.8 / 15.7
1,790 / 1,750
3,590 / 3,220

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Khs1822

Table of Contents