SUNON 10 Series Installation Manual

SUNON 10 Series Installation Manual

Powerful hvls fan

Advertisement

POWERFUL HVLS FAN
SERIES 10
Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SUNON 10 Series

  • Page 1 POWERFUL HVLS FAN SERIES 10 Installation Manual...
  • Page 2 12. SUNON Fans product warranty will not cover equipment damage or failure that is caused by improper installation or use.
  • Page 3 Thank you for purchasing SUNON products! Please read this manual carefully before use, use the product accordingly and keep the manual in safe place. In order to protect your rights and interests, please make sure that the deals records the purchase date, dealer’s name, etc. on the guarantee.
  • Page 4: Table Of Contents

    Table of Contents Introduction Page Fan Outline Product Specifications Installation Precautions The Placement & Clearance between fan and obstructions The Placement & Clearance between fan and HVAC diffuser Pre-Installation Page Inside the box Tools Required for Installation Fan Diagram Pre-Installation Checklist Installation Overview Page I-beam...
  • Page 5: Introduction

    Introduction Thanks for choosing our products, Powerful HVLS Fan is an efficient, economical and stylish choice. It’s energy-saving, eco-friendly design brings excellent airflow to space. We assure you this appliance will make your space cozier and occupant comfort in the near future.
  • Page 6: Product Specifications

    Introduction Product Specifications Powerful HVLS Fan series 10- 13 ft (4 m) Input Maximum Maximum Input Voltage Maximum RPM Noise Frequency Rated Power Rated Current (RPM) (dB(A)) (Hz) 220-240 50/60 Powerful HVLS Fan series 10- 16 ft (5 m) Input Maximum Maximum Input Voltage...
  • Page 7: Installation Precautions

    Introduction Installation Precautions 1. This HVLS fan need a proper device which can support its weight such as aerial work platform and at least two installation persons. 2. Please switch off all the power supply before installation to avoid the risk of electric shock or lighting shock.
  • Page 8: The Placement & Clearance Between Fan And Obstructions

    The Placement & Clearance between fan and obstructions The tip of airfoil need at least 2 ft (0.6 m) away from light or any equipment and no obstacles. The Ceiling fan need at least 10 ft (3.05 m) away from floor. The tip of the airfoil need at least 3.3ft (1 m) away from beam / ceiling and no obstacles.
  • Page 9: Pre-Installation

    Pre-Installation Inside the box Main Box Extension Tube Shield*2 Airfoil Strut*7 Safety Cable*1 Wire Rope Clamp*20 Turnbuckle*4 Beam Clamp Set*4 (with Motor)*1 Main Fan Unit Winglet*7 Earth Wire*1 Retainer*7 Extension Tube Shield (M6 16L Bolt Kit) Winglet(M6 40L Bolt Kit) J Box*1 Airfoil Strut (M10 Bolt Kit) Airfoil (M8 45L Bolt Kit)
  • Page 10: Tools Required For Installation

    Pre-Installation Tools Required for Installation Mechanical Installation Electrical Installation Standard wrench/socket set Phillips screwdriver Standard Allen wrench set Flat head screwdriver Hydraulic cutter Multimeter Galvanized wire Ø6 mm (Trim the wire Pair if #14 to #24 AWG strippers length according to the situation) Torque wrench 50~450 kgf.cm (For inspection purpose) Electronic level...
  • Page 11: Pre-Installation Checklist

    Pre-Installation Pre-Installation Checklist Equipped with appropriate mounting kit for roof pitch. The fan can only be mounted to the I-beam. DO NOT mount the fan directly to a single stringer, truss shelf or light steel shelf. For installation methods not included in this manual, please consult a structural engineer. The mounting structure approved by structural engineers.
  • Page 12: Installation Overview

    Installation Overview I-beam The yoke to I-beam for this HVLS fan is attached in our product. The yoke only can be used within the width of 135-375 mm (B) and thickness of 20 mm I-beam. Within the thickness of 14 mm (t), the yoke only need to use 1 yoke washer. The thickness of 14-20 mm (t), the yoke need 2 washers.
  • Page 13: Installing The Fan

    Installing the Fan Installation Method 1. Install the 7 sets of airfoil strut on the motor, this step can be completed on the ground. *Recommended Tightening Torque: 24 N.m (240 Kgf.cm) 2-1 Slide the motor, main fan unit to the side of yoke, hanger on the yoke and securely fasten.
  • Page 14 Installing the Fan 4-1 Secure the earth wire with the shaft of motor. 4-2 Connect three motor wires (u、v、 w) and earth wire to J Box. For waterproofing purpose, please use the waterproof joint. 4-3 Secure the extension tube shield with extension tube.
  • Page 15 Installing the Fan 7-1 Attach the beam clamps to the I-beam and securely fasten to the proper position based on step 5. 7-2 Pass the guy wire through the ring and secure with wire rope clamp. *Recommended Tightening Torque: 24 N.m (240 Kgf.cm) 8-1 Based on step 7, tighten the guy wire with turnbuckle and wire rope clamp as picture shows.
  • Page 16 Installing the Fan 10-1 Insert airfoil to airfoil strut. 10-2 Place retainer over the airfoil and spans to the next airfoil. Recommended Tightening Torque: 12 N.m (120 Kgf.cm) Installation Manual POWERFUL HVLS FAN SERIES 10...
  • Page 17: Fan Connection

    Installing the Fan Fan Connection Warning To avoid the risk of electric shock, please make sure that the wiring is in good electrical condition and all electricity supply should be disconnected. Above wiring should be implemented by a qualified electrician. To avoid the risk of electric shock, please make sure that all wires are insulated properly before the fan is turn on.
  • Page 18: J-Box

    Installing the Fan J-BOX Control Mode J-Box (Knob) J-Box (MODBUS) J-Box (RF) Installation Instructions Install the j-box in a location where authorized personnel can operate it. J-box should be installed in a safe area to avoid unintentional damage. When installing the j-box, make sure that the opening direction of panel is to the left, and do not interfere with the operation of the j box.
  • Page 19: Wiring Diagram

    Installing the Fan Wiring Diagram J-Box (Knob) J-Box (MODBUS) / J-Box (RF) Notes 1:The length should not exceed 30M, so as to avoid poor performance. Notes 2:The motor earth wire must be connected to the earth terminal on the J box to avoid high frequency electrical noise from the building wiring.
  • Page 20 Installing the Fan J-Box (Knob) Panel Description A.Power Switch Name Status Function Input Power OFF status Input Power ON status B.Rotation Direction Name Status Function Input Reverse STOP Input Stop Input Forward C.Speed Control Name Status Function Input Speed down Input Speed up Installation Manual...
  • Page 21 D.Motor Drive Interface Name Status Function Motor drive, connect to red wire from Output motor Motor drive, connect to white wire Output from motor Motor drive, connect to black wire Output from motor E.Break Name Status Function Input Power supply Input Neutral conductor G.Earth terminal...
  • Page 22 Installing the Fan J-Box (MODBUS) / J-Box (RF) Connection Setting Protocol MODBUS/RTU over MODBUS Baud Rate(bps) 9600 Data bits Parity bits none Stop bits For command table, please contact your service agent. Panel Description A.Power Switch Name Status Function Input Power OFF status Input Power ON status...
  • Page 23 E.Break Name Status Function Input Power supply Input Neutral conductor F.MODBUS Interface Name Status Function Receiver non-inverting input on the Input/ Output bus side, electrically isolated Receiver inverting input on the bus Input/ Output side, electrically isolated Ground, electrically isolated G.Earth Terminal Name Status...
  • Page 24: Rf Remote Control

    Installing the Fan RF Remote Control BUTTON FUNCTION Press each button to turn on the fan then you can set up the air volume. The number stands for air volume from low to high in numerical order ( 1 lowest to 6 highest volume). Press each button and the fan will give a short beep, you activate the fan successfully.
  • Page 25: Information

    Information Troubleshooting ▲ WARNING – Any fan component replacement, removal or disconnection of a safety device, all safety device must be reinstalled as formerly setting. ▲ WARNING– Please use this unit accordance with the manufacturer’s instructions. If you have any question, please contact the manufacturer. ▲...
  • Page 26: Maintenance

    SUNON suggests you to do the wire installation, please contact Customer Service if wobbling persists.
  • Page 27: Powerful Hvls Fan Series 10 Model List

    Information Powerful HVLS Fan series 10 Model List Taiwan Airfoil Dimension J-Box (Knob) J-Box (MODBUS ) J-Box (RF) 13 ft (4.0 m) BCTG1CB157A-01S BCTG1CC157A-01S BCTG1CA157A-01S 16 ft (5.0 m) BCTG1CB197A-01S BCTG1CC197A-01S BCTG1CA197A-01S 18 ft (5.5 m) BCTF1CB216A-01S BCTF1CC216A-01S BCTF1CA216A-01S 20 ft (6.1 m) BCTF1CB240A-01S BCTF1CC240A-01S BCTF1CA240A-01S...
  • Page 28: Warranty

    Information Warranty Purchase Date Serial Number Retailer's Stamp We offer 1 year warranty of our product starting from your purchase date. The following scenarios are excluded from our warranty service. Repairing request will be accepted, but the customer will be charge for cost and service fee. 1.
  • Page 29 Sunonwealth Electric Machine Industry Co., Ltd. 80673 No. 30, Ln. 296, Xinya Rd., Qianzhen Dist., Kaohsiung City 806, Taiwan (R.O.C.) e-mail : sunon@sunon.com www.sunon.com 20201230(V2) Installation Manual POWERFUL HVLS FAN SERIES 10...

This manual is also suitable for:

13 ft16 ft18 ft20 ft24 ft