Phason FC Seriess User Manual

Advertisement

FC-1T-1F user manual
The FC-1T-1F automatically controls the temperature in a room by switching fans, lamps, or heaters on or off as
the temperature drops below or exceeds the temperature set point.
When the SSC-1D is in cooling mode, it switches on the fans when the temperature exceeds the set point. When
the control is in heating mode, it switches on the lamps or heaters when the temperature drops below the set point.

Features

One solid-state relay
Heat and cool modes
Adjustable temperature set point,
32 to 99°F (0 to 37°C)
Fahrenheit and Celsius display
Six-foot temperature probe (extendable)

Installation

Switch OFF the power at the source before connecting the incoming power wires.
DO NOT switch on the power until you have finished all wiring and verified all equipment is
properly connected and free of obstructions.

Electrical ratings

Input:
120/230 VAC, 50/60 Hz
Relay:
10 A at 120/230 VAC, general-purpose (resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC
Fuse:
15 A, 250 VAC ABC-type ceramic
Temperature display units
FC-1T-1F
Error code display for troubleshooting
Overload protection fuse
Rugged, NEMA 4X enclosure (corrosion
resistant, water resistant, and fire retardant)
CSA approval
Two-year limited warranty
Mode of operation
1 / 4
10940000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FC Seriess and is the answer not in the manual?

Questions and answers

Summary of Contents for Phason FC Seriess

  • Page 1 FC-1T-1F user manual The FC-1T-1F automatically controls the temperature in a room by switching fans, lamps, or heaters on or off as the temperature drops below or exceeds the temperature set point. When the SSC-1D is in cooling mode, it switches on the fans when the temperature exceeds the set point. When the control is in heating mode, it switches on the lamps or heaters when the temperature drops below the set point.
  • Page 2 1. Set the to the correct position for the line voltage used, 120 or 230 VAC. voltage switch 2. Connect the wires as shown in the diagram. Startup When the control powers up: 1. 88 will display for 0.25 seconds (start-up). 2.
  • Page 3 S and the temperature display, indicating the knob has accidentally been turned. The control will not accept the new setting until the switch is clicked to the right. PhasonControls.com sales@phason.ca International: 204-233-1400 Toll-free North America: 800-590-9338 FC-1T-1F...

This manual is also suitable for:

Fc-1t-1f

Table of Contents