1.
SAFETY RULES
To ensure that the meter is used safely, follow all safety and operating instructions in
this operation manual. If the meter is not used as described in this operation manual,
the safety features of this meter might be impaired.
Do not look directly into the laser beam when the device is in use–permanent eye
damage may result.
Use extreme caution when operating the laser.
Never point the device towards anyone's eyes.
Keep out of reach of children.
2.
INTERNATIONAL SYMBOLS
Important information
see manual
3.
SPECIFICATIONS
Thermal Image Resolution
32 x 32
Visual Image Resolution
640 x 480
Measurement Range
-20 ~ +350°C (-4 ~ +662°F)
Accuracy (Tamb=20~26°C)
±2% of reading, or 2°C(4°F) whichever is greater
Thermal Sensitivity
0.1°C(0.1°F)
Frame Rate
9Hz
Field of View
33 x 33 deg
Emissivity Range
0.95 default – adjustable 0.1 to 1 step .01
Focus
Focus free
LCD (inch)
2.8
LCD Type
Color
Depends on the capacity of the Micro SD card. (ex: stores
Image Storage
up to 100,000 images, PNG format, for 16G Micro SD card)
Support Micro SD card up to 32G. (Recommend to use the
Memory Type
attached 16G Micro SD card)
Spectral Range
8 ~ 14um
Interface
USB (Data Transfer), SD Card
Battery Type
3.7V Li-ion rechargeable battery
3 hours continuous use (Li-ion rechargeable battery, with
Battery Life (with backlit)
backlight)
Dimensions
96 x 74 x 234 mm (3.8 x 2.9 x 9.2 inch)
Weight
345 g (12.17 oz) including the battery
IP Classification
IP54
Note: If using SDHC memory card other than supplied, recommend do test before use.
Typical full battery charging time 8hr. Do not charge overnight / without personnel
surveillant. Recommend charging 12hr for first time use.
4.
THERMOMETER DESCRIPTIONS
BT-71
Laser device. Avoid towards
anyone's eyes
(Fusion Mode)
5.
OPERATION
WARNING
1)
The measurement range is for thermometers only. Users should choose proper probe
types for different kinds of applications. Please make sure the target to be measured
will not exceed the temperature range of the probe to avoid permanent damage to the
thermocouple probe.
2)
Caution: DO NOT use the AC power adapter over output 5V 2A to avoid the product
damaged and failed to activate.
3)
EMC/RFI: Readings may be affected if the unit is operated within radiofrequency
electromagnetic field strength of approximately 3 volts per meter, but the instrument's
performance will not be permanently affected.
5.1
Operation Selection
Press "Power key" (2) for 2 seconds and then release it, the startup
Power On
process will complete in 15 seconds.
Press Mode Key (4) to switch the display mode. (Fusion-Thermal-Visual)
Display Mode
Note: Fusion is the default mode.
After power on, simply aim the thermal imager camera at the measure
Taking
target with Lens (10) and get the images and temperature immediately.
images and
Please make sure the target area is within the field of view.
temperature
Note: There is a cursor on the screen. The cursor shows the temperature
of the object located in the middle of the screen.
Press Trigger (11) to save the images to the micro SD card.
Save images
Note: When "
a micro SD card or it is not properly installed in the micro SD card slot (7).
Press Color Palette Key (3) to select the color palette (4 selectable color
Color palettes
palettes) to view thermal images.
Ironbow
Rainbow
°C/°F switch
Press Unit Key (5) to convert temperature unit.
Press Power Key (2) for more than 3 sec. to power off the device. Auto
Power off
power off time is around 1 minute. (Please see the "5.3 Setting" section to
learn how to adjust the auto off time.)
5.2
Function Selection
Press Menu Key (6) to display functions, then press Color Palette Key (3) or
Mode Key (4) to select the function. Under the function mode, press Unit Key
(5) for setting and then press Trigger (11) to confirm it.
Cursor Measurement
3-level brightness
Brightness
Fusion images by 3-level ratio of combining thermal and
visual images.
Fusion Ratio
View image: After selecting the image folder, press Trigger
(11) to view images stored on the micro SD card.
Delete image: After selecting the image folder or image
file, press and hold Trigger (11) and TIPS "Do you want
to delete it?" appears on the LCD. If you do not want
File Management
to delete the file, select "NO" and press Trigger (11) to
confirm it; if you want to delete the file, press Unit Key
(5) to select "YES", then press Trigger (11) to confirm the
deletion.
Note: If you want to manage images on the computer,
please use the USB cable to connect the device and the
computer.
5.3
Setting Selection
Emissivity
HAL Temp
LAL Temp
Setting
Save Mode
Auto Off
Target Distance
Languages
Set Date and Time
" icon appears on the LCD, please check if there is
High contrast
The cursor shows the temperature of the object
located in the middle of the screen.
Hide the cursor measurement.
LOW
Medium
(
is the default mode)
The default emissivity is 0.95, or select other default
emissivity: Blackbody:1.0, Matt:0.95, Semi-
matt:0.8, Semi-glossy:0.6, Glossy:0.3 Select Set
E value to adjust the emissivity (0.1 to 1 step .01).
When the reading is outside the High Alarm (HAL)
or Lo Alarm (LAL) limit, the reading (HAL: red
texts, LAL:blue texts) shown at the top left corner
of screen will flash with two short beep sound
constantly. Select HAL Temp or LAL Temp to adjust
the limits or select ON/OFF to turn on/off the alert.(
step 1)
Select Photo: Save fusion/thermal/visual images in
photo mode. (PNG and Excel formats)
Select Video: Save fusion/thermal/visual images in
video mode.
The default setting is "Auto off 1 min", you can
select other default value: 5, 10, 20 minutes or "No
auto off".
Manually power off the device by pressing Power
Key (2) for 3 seconds.
The maximum distance is between the thermal
imager camera and the target.
English/French/German/Dutch/Portuguese/Italian/
Spanish/Traditional Chinese/Simplified Chinese/
Japanese
Set the date and time in MM/DD/YYYY (month/day/
year) and HH/MM/SS (hour/minute/second) formats.
Grayscale
High

Advertisement

loading

Summary of Contents for BSi BT-71

  • Page 1 BT-71 IR THERMAL IMAGER CAMERA OPERATION WARNING OPERATION MANUAL The measurement range is for thermometers only. Users should choose proper probe types for different kinds of applications. Please make sure the target to be measured will not exceed the temperature range of the probe to avoid permanent damage to the thermocouple probe.
  • Page 2 ‘Battery Exhausted’: Thermometer does not function When the ‘Low Battery’ icon indicates the battery is low, the battery should be recharged by BT-71 REV1.0/MAY22 USB port. Dispose of used battery promptly and keep away from children.