8. Level 3 Repair
8-4-7-1. 6AXIS (Accelerator+Gyro) Sensor
6AXIS Sensor does not work
Check the voltage
C3098, 3099 =1.8V
Check R4228, R4231
(crack, open, etc.)
Check U3012
(crack, open, etc.)
Confidential and proprietary-the contents in this service guide subject to change without prior notice
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
Yes
Yes
Yes
Yes
END
No
Abnormal
Abnormal
Replace U3013 (LDO)
Replace R4228, R4231
Replace U3012