RECEIVING & INSTALLATION NOTE: The HIX TT-180D is not compatible with the M&R Trilok pin registration system.” CAUTION: Before installing or operating the unit be sure to read these instructions thoroughly. Disconnect all electric power before performing maintenance on the unit. Never operate this equip- ment with the power supply cover removed.
OPERATION WARNING: During operation, make sure the lid is latched on both sides to prevent UV light exposure to eyes or skin. LOADING SCREEN / STARTING VACUUM Maximum screen sizes: 23” x 31” NOTE: Put the screen in the center of the glass. Keep at least 2” from any edge of the glass to prevent damage to the vacuum blanket rubber.
Page 4
OPERATION DIGITAL TIMER 1. Turn Main Power “On”. Timer will illuminate. 2. To change time setting, press the button on the front of the timer face. Timer will display “Minutes” and “Seconds”. 3. To program the desired number for the fl ashing column, press button;...
SCREEN EXPOSURE DETERMINING YOUR OPTIMUM EXPOSURE TIME NOTE: This procedure should be followed for each new emulsion type, new mesh count or mesh type (i.e. yellow, orange, white). This procedure should also be followed periodically since the bulb intensity will lessen with age. Exposure Calculator (Preferred Method) See your emulsion supplier for an exposure calculator and follow their instructions.
MAINTENANCE GLASS CLEANING OR BULB REPLACEMENT In order to maintain short exposure times, keep the unit’s ex- posure glass clean. Dusting is usually suffi cient. If more clean- ing is required use a soft cloth moistened with alcohol. A dusty environment will require more cleaning.
NOTE: If the blanket fails to pull a vacuum, check the Troubleshoot- ing Chart for possible causes. If you determine that your blanket has begun to leak, it needs to be replaced. New blanket material can be ordered from HIX Corporation.
REPAIRS NOTE: Mark from which side the aluminum strips were located so that they can be replaced in the same location. 1. Begin with the lid in the open position. Remove the plastic cap from the lid end of one of the gas springs. While holding the lid, pull the end of the gas spring straight out and off of the ball connector as you continue to manually hold the lid up.
Thermatrol and doughXpress products are covered under separate warranty. In the event of a defect, HIX, at its option, will repair, replace or substitute the defective item at no cost during this period subject to the limitations of insurance and shipping costs stated below.
Need help?
Do you have a question about the TT-180D and is the answer not in the manual?