HydroQuip Silent Aire Series Installation & Owner's Manual

HydroQuip Silent Aire Series Installation & Owner's Manual

High-performance / low noise air blower

Advertisement

Quick Links

Installation & Owner's
Manual
Silent Aire
TM
Series
High-Performance / Low Noise
Air Blower

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Silent Aire Series and is the answer not in the manual?

Questions and answers

Summary of Contents for HydroQuip Silent Aire Series

  • Page 1 Installation & Owner’s Manual Silent Aire Series High-Performance / Low Noise Air Blower...
  • Page 2 IMPORTANT: Please provide these operating instructions to the end user. All printed material should be read thoroughly prior to using the product. These instructions are provided for reference only. Individuals not familiar with portable spas and hydro-therapy baths should seek advice from professionals before using this product or attempting it’s installation.
  • Page 3: Installation Considerations

    INSTALLATION CONSIDERATIONS: There are many variables to consider when choosing the proper size air blower for your spa or hot tub. These include: water depth, the number and size of air holes, distance of blower from spa, number of 90 and 45 degree turns, and the size of the supply line.
  • Page 4: Blower Installation

    APPLICATION: The Hydro-Quip Silent Aire Spa & Bath Blower has been engineered to provide years of trouble free use provided it is installed following the parameters provided within this installation manual. Failure to follow these instructions may result in premature failure and voids all manufacture warranties.
  • Page 5: Operation

    OPERATION: Startup Check List Check that all air tubing is connected to the injectors and any associated ü manifolds Check for pinched air injector lines ü Check for leaks, always ü Check power cord is connected to control ü ü Make sure the blower circuit voltage matches the blower voltage. Startup: 1.
  • Page 6: Troubleshooting

    TROUBLESHOOTING SYMPTOM CAUSE SOLUTION Check circuit breaker. A GFCI should be Blower will not No Power at power point. present. If GFCI trips repeatedly do not use operate. blower until issue is corrected Verify blower is installed in accordance with Moisture/Water present in the instructions.
  • Page 7: Maintenance

    HYDROQUIP will repair or replace the part, if in our opinion, the unit is defective. This warranty excludes damage as a result of: water intrusion, normal wear, freezing, low/high voltage, chemical abuse, accident, negligence, alteration, improper installation, use or care.
  • Page 8 510A N. Sheridan St. Corona, CA 92880 www.hotwatercontrols.com 85-0021 -REV.04 - 05/19...