ERC FAILURE CODES

The oven may stop operating but not give an F code on the display immediately.
F codes are stored in nonvolatile EEPROM memory until the same fault occurs
twice consecutively. F codes can be recalled by pressing together TIMER, CLOCK
and 9. While F codes are displayed, pressing 8 and 6 together will clear them. A
fault must exist continuously for 5 minutes before an F code is recorded (F2 and
F8 are sooner).
FAILURE
CODE
MEANING
CORRECTION
-F0-
Shorted OFF key (Mem-
• Welded relay contacts
-F2-
Over temperature
• Cooling fan stalled or blocked
by sensor over 650°F unlatched or
• High resistance in oven sensor leads/connectors
915°F latched
-F3-
Open oven sensor (under 950
be ~
• Look for damaged harness terminals if not a bad
-F4-
Shorted oven sensor (over
be ~
-F7-
Determine if problem is with key panel or control by
key
EEPROM data shift failure
Cooling fan stalls while above
-F9-
650°F; open thermal switch in
yellow lead
-FC-
Loss of latch motor safety
circuit

MOTORIZED DOOR LOCK

The motorized door lock assembly is located above the oven. The assembly
consists of a lock motor cam and switch assembly, lock hook and mounting
plate.
MOTORIZED DOOR LOCK OPERATION
The lock motor is energized when the control is set for Clean and Clean Time
is selected. The K4 Relay contacts will close and complete the circuit that
supplies the voltage to the lock motor.
if the door switch is in the "C" to "NC" position
(door open).
motion. When the door is locked, the words
"LOCKED DOOR" remain illuminated in the
display.
• CAM – The cam on the motor performs two
functions:
1. Positions the lock hook in the door to
prevent opening during clean operation.
2. Operates the lock switches which tell the
control if the door is unlocked or locked
and ready for Clean operation.
NOTE: When
UNLOCKED
door is
LOCK SW. CIRCUIT
SENSOR AND LOCK
SWITCH CONNECTORS
LOCK SW. #1
either being
8
locked or
THERMAL
LOCK
unlocked,
SWITCH
THERMAL SWITCH
6
SW. #2
5
DOOR LATCH OUTPUT PIN 5, -25V DC
both lock
4
DOOR LATCHED INPUT PIN
3
DOOR UNLATCHED INPUT PIN
switches
will be in
the open
LOCKED
position.
LOCK SW. CIRCUIT
SENSOR AND LOCK
SWITCH CONNECTORS
LOCK SW. #2
8
THERMAL
LOCK
SWITCH
SW. #1
THERMAL SWITCH
6
5
DOOR LATCH OUTPUT PIN 5, -25V DC
4
DOOR LATCHED INPUT PIN
DOOR UNLATCHED INPUT PIN
3
SH. 3 of 4
31-17264
Category Fault
Description
Fault Actions
Code
100
Latch all heating
elements and cooktop
Range Miswired after 10 mins
Thermal
200
Cavity 1 Thermal Runaway when
Unlocked
Runaway
210
Cavity 1 Thermal Runaway when
Locked
Sensors
300
RTD1 sensor short-circuit detected
Stop ovens
310
RTD1 sensor open-circuit detected
Stop ovens
350
Cooling Fan Speed Fault
Stop cooktop
Stop ovens
351
Cooling Fan Unexpected Operation
Fault
352
Cooling Fan Rotor Fault
Stop cooktop
Stop ovens
Communi-
630
Gen board 1 heartbeat missing
Stop Cooktop
cation
640
Gen board 2 heartbeat missing
Stop Cooktop
650
Radiant board heartbeat missing
Stop Cooktop
Left wing board UI heartbeat missing
Stop Cooktop
Center UI board heartbeat missing
Stop Ovens
Right wing board UI heartbeat missing Stop Cooktop
Keys
700
710
Cancel Key Scanning Failed - RC15
Only
720
Oven Stuck Key - RC15 Only
Stop Ovens
Stop Cooktop
730
Wing Board Knob 1 Out of Range
Stop cooktop
731
Wing Board Knob 2 Out of Range
Stop cooktop
732
Wing Board Knob 3 Out of Range
Stop cooktop
733
Wing Board Knob 4 Out of Range
Stop cooktop
734
Wing Board Knob 5 Out of Range
Stop cooktop
735
Wing Board Knob 6 Out of Range
Stop cooktop
741
Stop Cooktop
board Knob 1
742
Stop Cooktop
board Knob 2
743
Stop Cooktop
board Knob 3
744
Stop Cooktop
board Knob 4
745
Stop Cooktop
board Knob 5
746
Stop Cooktop
board Knob 6
UI Checks - Left wing touch
Stop Cooktop
UI Checks - Oven UI
Stop Ovens
UI Checks - Right wing touch
Stop Cooktop
Clean Two Step On Error Cavity 1 -
self clean started without 2 key inputs
Cavity 1 heating element relay in
unexpected state
900
Cavity 1 door lock changed states
unexpectedly
Induction
910
Cavity 1 door lock failed to change to
Fan
expected state
940
Cavity 1 door detected as open when
locked
960
Cavity 1 door lock is in an unknown
state
Displayed
Total
Set Conditions
(Yes/No)
Debounce
Seconds
Yes
2
Yes
60
Yes
60
130
120
30
30
25
0
0
0
0
0
0
Yes
~100
Yes
110
100
15
15
15
15
15
15
0
0
0
Yes
0
Yes
0
Yes
0
Yes
2
Yes
0
Yes
30
Yes
0
Clear Conditions
Possible Cause(s)
System miswired
on power up, if oven no longer
Cleared when the miswire condition
-
Press cancel to reset system
Press cancel to reset system
The fan speed returns to 200 RPM
-
The cooling fan speed is outside the
Heartbeat received with changing
Heartbeat received with changing
Heartbeat received with changing
Heartbeat received with changing
Heartbeat received with changing
Heartbeat received with changing
Press cancel to reset system
Press cancel to reset system
Software error or RC15 control
Clears when the stuck key condition
clears
Count in range
Count in range
Count in range
Count in range
Count in range
Count in range
Mismatch falls to or below 100
If primary and redundant mismatch
by 100 counts for 15 seconds, set
Mismatch falls to or below 100
If primary and redundant mismatch
by 100 counts for 15 seconds, set
Mismatch falls to or below 100
If primary and redundant mismatch
by 100 counts for 15 seconds, set
Mismatch falls to or below 100
If primary and redundant mismatch
by 100 counts for 15 seconds, set
Mismatch falls to or below 100
If primary and redundant mismatch
by 100 counts for 15 seconds, set
Mismatch falls to or below 100
If primary and redundant mismatch
by 100 counts for 15 seconds, set
Cleared when left wing resets
Cleared when oven UI resets
Cleared when right wing resets
Press cancel to reset system
Bad RC17 control
Press cancel to reset system
Bad RC17 control
Press cancel to reset system
Bad RC17 control
Press cancel to reset system
Press cancel to reset system
Press cancel to reset system
Press cancel to reset system