Advertisement

Quick Links

BS33
MODEL
Cable Length Meter
User s
'
Manual
(C) Copyright BSTCaltek 2011
REV2.1/MAR.11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BS33 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BST BS33

  • Page 1 BS33 MODEL Cable Length Meter User s Manual (C) Copyright BSTCaltek 2011 REV2.1/MAR.11...
  • Page 2: Table Of Contents

    BS33 Index INTRODUCTION ........................3 FEATURES..........................3 SPECIFICATIONS ........................4 CALIBRATION PROCEDURE ....................6 MEASURING LENGTH OF WIRE.................... 7 USER SELECT MODE ......................8 LOW BATTERY INDICATION....................10 MEASURING RESISTANCE ....................10 OPERATIONAL HINTS......................10 10. SERVICE ..........................11 Remarks: Due to our policy of continual product development, we reserve the right to amend the specifications of the mentioned...
  • Page 3: Introduction

    BS33 1. INTRODUCTION BS33 can quickly measure length of any reeled wire up to 30,000m (100,000ft) and with the gauges from 0.15mm² to 240mm² (Standard mode). Within seconds, cable of Copper or Aluminum length up to 30,000m can be measured and digitally displayed without the cumbersome unrolling of cable reels.
  • Page 4: Specifications

    BS33 3. SPECIFICATIONS Length limit: 0.1 to 30.00km Standard gauge mode cross section limit: 0.15mm to 240 mm User select mode cross section limit: 0.15mm to 6.0 mm Due to the minimum and maximum resistance limits, specific wires will have a range specific to that wire.
  • Page 5 BS33 Resolution: 0.1m or 0.5 feet(Length) 1mΩ (Resistance) Accuracy: ±(1% of reading +1m or 3ft)< 100m or 300ft at 18℃ to 23℃ ±(1% of reading)> 100m or 300ft at 18℃ to 23℃ ±(2% of reading +1m or 3ft)< 100m or 300ft below 18℃ and above 23℃...
  • Page 6: Calibration Procedure

    BS33 4. CALIBRATION PROCEDURE (Perform this function before testing) 1. Turn the rotary selector from off to any position to turn the meter on. 2. Set the rotary selector to “ ” on the dial. 3. Insert the black test leads into one pair of input jacks and the red test leads into the other pair of input jacks.
  • Page 7: Measuring Length Of Wire

    The insulation must be stripped away so the Kelvin clips can be good connected across the diameter of the wire. 4. Using the selector on the BS33, turn to the size of wire under test. 5. Press the “COPPER” button if copper wire is being tested. The “...
  • Page 8: User Select Mode

    BS33 6. USER SELECT MODE This mode allows you to save the resistance of a user wire (See NOTE below) for additional measurements of unknown lengths of the same gauge wire. In addition, it enables you to accurately measure the length of standard gauge wires. In this mode, you can measure the length of any metal wire, the resistance of which can be measured, as well as Copper or Aluminum wires.
  • Page 9 BS33 Measuring Length of Wire in the User Select Mode 1. Turn on the meter and perform the calibration procedure first. 2. Allow the meter to attain the same temperature as the wire under test. WARNING: MAKE SURE WIRE UNDER TEST IS NOT ENERGIZED.
  • Page 10: Low Battery Indication

    BS33 7. LOW BATTERY INDICATION If the battery voltage is low, the “BAT “ enunciator will illuminate at the top right corner of the display. The battery should be changed immediately to ensure function and accuracy is according to the specification. Only alkaline 9volt battery should be used.
  • Page 11: Service

    BS33 10. SERVICE Warranty Conditions This meter is guaranteed against any material fault or manufacturer’s defect, in accordance with the general conditions of sale. During the warranty period (one year), faulty parts may be replaced, with the manufacturer reserving the right to decide either to repair or replace the product.
  • Page 12 BS33 Service If the meter should not work properly, before contacting the DEALER OR THE SERVICE CENTRE, check the battery condition, the test leads, etc., Change them if necessary. If the meter still does not work, check if your operating procedure agrees with the description in this manual.