Page 1
Controls Bacteria and Algae in Swimming Pool and Spa Water For Domestic Use. A maximum of 96 000 L of water can be treated with one VX7 Salt Chlorine Generator. Maximum daily output of hypochlorous acid equivalent to 0.48 kg/day output of free available chlorine.
Page 2
REGISTRATION NUMBER 31186 PEST CONTROL PRODUCTS ACT. This cell must only be used on this model of chlorine generating device. Read the Label and the Installation and Operation Manual for the VX7 Salt Chlorine Generator before using. Fluidra Group Australia PTY LTD...
Page 3
OWNERS MANUAL VX7 Salt Chlorine Generator Controls Bacteria and Algae in Swimming Pool and Spa Water DOMESTIC INSTALLATION/OPERATION MANUAL REGISTRATION NO. 31186 PEST CONTROL PRODUCTS ACT KEEP OUT OF REACH OF CHILDREN READ THE LABEL AND OPERATING MANUAL BEFORE USING...
Page 4
VX7 Salt C h l o r i n e G e n e r a t o r It is said that all life evolved from the sea and that salt water makes up 70% of our bodies, so it's little wonder we find salt water the most natural medium to swim in.
Page 5
VX7 will automatically extend its operating hours to allow for additional filtration and sanitation during Mineral Salts The VX7 Salt Chlorine Generator is suitable for use with pool salt AstralPool's unique AcquaTherape Minerals which give the pool water a softer feel and help prevent staining and calcification.
INDEX{TABLE OF CONTENTS) 0.0 Important Safety Warnings ..........................5-7 1.0 General Overview ................................8 1.1 Chlorinator Control Unit Installation........................8 1.2 Cell Installation…………..............................9 1.3 Pool Preparation ................................10 ..............................2.1 User Panel 2.2 Chlorine Output ................................13 2.3 User Mode .............................................14 3.0 Warnings Display………………………………………………………………………………………………………………………….15 3.1 Chlorine O u t p u t Level .........................16 3.2 Safety Backwash ...............................
0.0 IMPORTANT SAFETY WARNINGS W hen installing and using this electrical equipment, basic safety precautions should always be followed, including the following: -READ AND FOLLOW ALL INSTRUCTIONS IN THIS M ANUAL. – To reduce the risk of injury, do not permit children to use this product. –...
Page 8
The life expectancy of the electrolytic cell is 15 000 h o u r s under normal use conditions. -Operating the VX7 Salt Chlorine Generator without water flow through the cell can cause a build-up of flammable gas which can result in FIRE OR...
Page 9
15 minutes. RISK OF HYPERTHERMIA. -W hen replacing the cell, only use replacement cells having a label t h a t clearly states that it is a replacement cell for the VX7 Salt Chlorine Generator, matching specific chlorinator model.
Your VX7 Salt Chlorine Generator works by converting some of the salt in your pool into chlorine which starts to destroy algae and bacteria in your pool water thereby sanitizing your pool. As part of the process, the chlorine is converted back into salt and hence salt is not consumed.
Page 11
The chlorinator cell must be located last in the pipe work just prior to the return to the pool. If valves are installed between the chlorinator control unit and the pool outlet, it is essential that they cannot deadhead the pump. If the pressure in the cell exceeds 150 kPa (22 psi) and/or the water temperature exceeds 40°C (104°F), the cell may fail.
Once the cell is installed , connect the black multi-core cable from the chlorinator control unit to the cell. The blue wire must be connected to the blue terminal. The (multi-core) 4–wire cable wires are color coded to match their corresponding connection points in the cell—the posts fit into the corresponding color keyed sockets on the connector end of the cell housing.
2.1 USER PANEL The user panel can be broken down into 4 separate areas : 1. Display Area 2. Chlorine Output Controls for setting the chlorine output level and to activate the Safety Backwash Feature. 3. Warnings display to indicate that there is no flow to the cell or there is insufficient salt in the pool. 4.
2.3 USER MODE The user mode buttons enable you to select Pool or Spa mode and to manually control the Chlorinator/Pump. Functions are as follows: POOL MODE Sends a message to other ASTRAL equipment (if fitted) to go to Pool mode. Auto Not Used The Chlorinator/Pump will run continuously.
Press to Select Pool Mode. Not Used Repeated pressing alternates from On Auto Indicates to Standby/Off Pool Chlorinator/Pump Mode manually on Standby/Off Indicates Pump/Chlorinator Mode manually off Press to Turn On/Off Spa Mode 3.0 WARNINGS DISPLAY Apart from messages displayed on the User display, there are two warning indicators. (a) LOW SALT: This indicates that the concentration of salt has reduced within your pool.
User Mode Your VX7 Salt Chlorine Generator will always attempt to adjust the output so that the actual output level matches set point level. At times when the Chlorine output level is lower than the set point, check the salt level in your swimming pool at your local pool shop.
3.3 RUN DRY SAFETY FEATURE Your VX7 Salt Chlorine Generator incorporates a run dry safety cut out. When the Chlorinator turns the filter pump on, it will check for water flow. If no water flow is detected within 3 minutes, the chlorinator will turn the pump off. This is designed to protect the pump seal and parts from overheating if no water flow is present.
A typical pool of around 50 000 L (13 210 gals) requires 200 kg (441 lbs) of salt to initially set-up the pool to 4000 ppm. A low salt level warning is indicated on your VX7 Salt Chlorine Generator if the salt level drops. If Low Salt is indicated, check again in 24 hours and then if it is still indicated, add two 25 kg (55 lb) bags of salt to the shallow end of your pool.
VX7 Salt Chlorine Generator cells have a negative charge sensor that monitors the flow and salt levels of the water. This sensor is designed to be fail safe. As the cathode electrodes are negatively charged, deposits of calcium, or other (positive charged) dissolved minerals and debris, may deposit on them and cause the system to indicate a false low salt, or no flow condition--due to the electrodes' electrical resistance increasing.
4.2 Scheduled Chlorinator Maintenance Maintenance Schedule: Your new product incorporates moving parts and withstands high velocity water with chemicals in it. Some of these parts will wear in the normal course of use and require regular checks and maintenance. Performing these checks and maintenance will identify parts that have worn and require repair/replacement before further serious damage is sustained.
5.0 TROUBLESHOOTING Fault Indication Potential Cause Remedy No Flow Pump turned off/disconnected or valves Ensure valves/pump on closed Blue wire disconnected from cell Connect Blue sense wire to cell Low salt Salt level in pool has dropped too low See section 3.5 above Pool water temperature is low See section 3.5 above Cell has calcified...
(c) waive any objection it may have to the laying of venue of any such suit, action or proceeding in any such court. The prevailing party will be entitled to costs and reasonable attorney fees. ASTRAL USA, Div. Fluidra 8525 Mallory Road...