Do you have a question about the Compu-Chlor CPA Series and is the answer not in the manual?
Questions and answers
Summary of Contents for compupool products Compu-Chlor CPA Series
Page 1
17-SEP-2008 Sub. No. 2008-1581 12-JUN-2008 Notification LABEL COMPU-CHLOR CPA150 ELECTROLYTIC CHLORINATOR CHLORINE GENERATING DEVICE DOMESTIC FOR RESIDENTIAL POOLS AND SPAS KEEP OUT OF REACH OF CHILDREN REGISTRATION NO. 28744 PEST CONTROL PRODUCTS ACT READ THE LABEL AND OWNER'S MANUAL BEFORE USING Can treat a maximum volume of 25,000 litres THE COMPU-CHLOR CPA150 ELECTROLYIC CHLORINATOR CONTAINS A POWER SUPPLY AND A CELL.
Page 2
17-SEP-2008 Sub. No. 2008-1581 REPLACEMENT CELL LABEL COMPU-CHLOR CPA150 ELECTROLYTIC CHLORINATOR REPLACEMENT CELL A150C Tiffany Holdings PTY LTD D.B.A. Compu Pool Products Compu Pool Products P.O. Box 670 88 Spencer Street Nerang Queensland 4211 Nerang QLD 4211 Australia Australia Somagent Synergies Inc. Notification Change 129 de Touraine, St-Lambert, QC J4S 1H3...
Page 3
17-SEP-2008 Sub. No. 2008-1581 CPA Series Model Compu-Chlor CPA 150 Owner’s Manual Compu Pool Products 88 Spen Tiffany Holdings PTY LTD D.B.A. Compu Pool Products 88 Spencer Street P.O. Box 670 Nerang QLD 4211 Australia Nerang Queensland 4211 Notification Change Somagent Synergies Inc.
SAFETY INSTRUCTIONS Congratulations on your recent purchase of a Compu Pool Product Salt Water Generator. Please take a moment to read through the entire manual before installing your new unit. Your generator must be installed and operated as specified. IMPORTANT SAFETY INSTRUCTIONS. READ AND FOLLOW ALL INSTRUCTIONS. SAVE ALL INSTRUCTIONS.
COMPU-CHLOR CPA150 OWNERS MANUAL OPERATION- COMPU-CHLOR CPA150 The chlorinator Power Unit is to be mounted at least 1.0 metre above ground level and if possible protected from direct weather. The Chlorinator Electrolytic Cell is to be fitted into the return to pool line after the pump and filter.
Page 6
Chlorine Stabilizer (cyanuric acid): Chlorine Stabilizer is needed to maintain proper levels of chlorine. Most unstable chlorine is destroyed by the UV radiation from the sun within 2 hours. Chlorine stabilizer must be maintained between 40 – 100 PPM. Nitrates: Nitrates can cause extremely high chlorine demands and will deplete chlorine from your swimming pool.
button. When setting the timer use the up and down arrow keys to move the cursor and select the correct time. INDICATOR’S LED’s POWER: When illuminated, the Compu-Chlor CPA150 unit has input power activate. POLARITY 1 & 2: When illuminated, it indicates which side of the cell is producing. NO FLOW: When illuminated, the flow switch has detected no water flowing and the Compu-Chlor CPA150 unit has stopped generating chlorine.
Page 8
Oval Length x Width x Length x Width x Average Depth x 6.7 Average Depth x 893 The ideal salt level is between 3000- 6000 ppm., with 6000 ppm being optimal If the level is low, determine the number of litres (gallons) in the pool and add salt according to chart 1. A low salt level will reduce the efficiency of the Compu-Chlor CPA150 and result in low chlorine production.
Always check that the cell connections at the junction box under the power unit are tight and correctly matched when replaced if disconnected for cleaning. WARNING FOR QUALITY AND VALUE – INSIST YOUR CHLORINATOR IS ONLY SERVICED WITH GENUINE REPLACEMENT PARTS AVAILABLE FROM MANUFACTURER – COMPU POOL PRODUCTS HELPFUL HINTS When the chlorine Monitor is indicating in the green normal region and the Cell is clean, then the...
Page 10
unit • Check fuse on power unit • Check filter pump running • Check water flow through Cell is sufficient • Check for air in system (3) WATER FLOW THROUGH • Check operation of pump CELL IS LOW • Check filter is clean •...
Page 11
WARRANTY Compu-Chlor CPA 150 automatic salt water generator model CPA150 carries the following warranty should fault occur due to faulty manufacture or materials. Compu Pool Products warrants the original purchaser of the unit for a period of 5 full years on the power controller and on the cell from the date of purchase by the owners, should examination disclose to its satisfaction the unit has failed due to faulty manufacture or materials.
Page 12
****************************** This label transcript service is offered by the Pest Management Regulatory Agency to provide efficient searching for label information. This service and this information do not replace the official hard-copy label. The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate, current or correct, and is therefore not liable for any loss resulting, directly or indirectly, from reliance upon this service.