Игорь
May 19, 2025

Добрый день. Весы стали взвешивать только до 100 грамм. Какой выход из ситуации?

1 comments:
Mr. Anderson
May 23, 2025

The TIMEMORE BLACK MIRROR 2 scale is designed to weigh up to 2 kilograms (2000 grams) with 0.1 gram precision. If it only weighs up to 100 grams, it may be due to a malfunction, incorrect calibration, or a setting issue.

To try to fix it:

1. Check for calibration options – Reset or recalibrate the scale if the instructions allow.
2. Inspect the surface – Ensure the scale is on a flat, stable surface.
3. Restart the scale – Turn it off and on again to reset.
4. Check for damage or obstruction – Make sure nothing is interfering with the weighing platform.
5. Review the manual – Use the label or overlay provided to check if a mode or setting is limiting the weight.

If the issue remains, it may require repair or replacement.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for TIMEMORE BLACK MIRROR 2

  • Page 1 TIMEMORE BLACK MIRROR 2 COFFEE WEIGHING PANEL User' s Manual...
  • Page 2 Package contents & functions The product needs to be installed before using. The components include in this package: Base×1 (including the connecting piece/screw) Bracket ×1 Dripper Holder ×1 Silicone Pad ×1 TYPE-C Cable ×1 Up/Down Adjustable Knob (Use the large knob for adjustments) Power Button TYPE-C Charging Port Please remove the protection pads as...
  • Page 3 The Installation and Usage of Dripper Bracket 1. The dripper holder can be easily Insert the rod into the hole as shown, installed and removed. Please remove fix and tighten the screw below the the silicone pad before installation. connecting piece to fix the bracket The connecting piece/screw on the (see the figure below).
  • Page 4 Introduction to Buttons and Display Area 7 8 9 10 Power/Tare Button: Press to power on Short press to tare Long press 2 seconds to power o Timer Button: Short press to start/pause timer Press for 1 second to reset timer Press for 5 seconds to turn on/o the beep Quick press 8 times to turn on/o auto timer mode Time: Max recording time is 59m:59s...
  • Page 5 The Display of Dual Co ee Weights Total weight of water injection Weight of extracted co ee Auto Timer Mode The mode is based on ONLY regular mode which is when the device is NOT connected with App or Mini Program. To turn on/o Auto Timer mode, press the Prepare brewing equipment and place on timer button 8 times until you hear the...
  • Page 6: Specification

    Specification 01. Product Name: TIMEMORE BLACK MIRROR 2 Co ee Weighing Panel 02. Measure range: 0.5g-2000g 03. Storage temperature: -10℃ to 55℃ 04. Use temperature: Surface -10℃ to 60℃ With silicone pad : -20℃ to 100℃ 05. Key mode: Capacitive touch ( no need to press hard ) 06.
  • Page 7: Smartphone App

    Smartphone App 1. Scan the below QR code and get into www.timemore.com - Download Center to download [TIMEMORE] application. Android After installation, please complete the registration or login account to learn more under [Brewing], [Data], [Device] interfaces. 2. Scan the QR code and get into Mini Program [TIMEMORE] via Wechat.
  • Page 8 网址: www.timemore.com 电话: 400-684-0200 生产商: 可瑞尔科技(扬州)有限公司 地 址: 江苏省扬州市开发区兴扬路28号 Product name: TIMEMORE BLACK MIRROR 2 Co ee Weighing Panel Item’s number:TES008 Contents: Weighing Panel, Bracket, Dripper Holder, Silicone Pad, Charge Cable, User’s manual (Warranty Card), Certification Company : Shanghai TIMEMORE Co ee Equipment CO., LTD.
  • Page 9: Fcc Statement

    FCC statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.

This manual is also suitable for:

Tes008