Advertisement

Quick Links

X618
MODEL V8400H-H HEATER,
V8400H-B BLOWER AND V8400H-DEF
DEFOGGER FOR V8400H-17-HT HOUSING
Warning: To reduce a risk of fire or electric shock, do not expose this product to rain or moisture.
Copyright © 1998 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300 INFOFAX: 800-287-1207 WEB: www.vicon-cctv.com
Vicon part number 8006-8618-02-00
Rev 1298 Section 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X618 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vicon X618

  • Page 1 Copyright © 1998 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon and its logo are registered trademarks of Vicon Industries Inc. VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 INFOFAX: 800-287-1207 WEB: www.vicon-cctv.com...
  • Page 5: Table Of Contents

    Introduction ............................1 Installation............................3 Installing the V8400H-H Heater......................3 Installing the V8400H-B Blower......................5 Installing the V8400H-DEF Defogger..................... 6 Jumper Wire Assembly........................7 Shipping Instructions........................8 Technical Information ........................9 Contents • • i X618 Rev 1298 V8400H-17-HT Housing Accessories...
  • Page 6 Wiring Diagram for the V8400H Housing ....................5 Figure 4 Location of Defogger Assembly ......................6 Figure 5 Wiring the Defogger Through the Housing....................6 Figure 6 Jumper Wire Connections........................7 ii • • List of Figures X618 Rev 1298 V8400H-17-HT Housing Accessories...
  • Page 7 Use only with a mounting accessory recommended by Vicon, or sold with the video product. Any mounting of the video product should follow Vicon’s instructions, and a mounting accessory recommended by Vicon should be used.
  • Page 8 Vicon or that have the 15. Power Lines - An outside cable system should not same characteristics as the original part. Unauthorized...
  • Page 9: Introduction

    12.5 W of heater power at 120 and 230 VAC (Models V8400H-DEF and V8400H-DEF-230, respectively). All wiring is located in the rear end-cap, which provides strain relief and protection from shock hazard. Introduction • • 1 X618 Rev 1298 V8400H-17-HT Housing Accessories...
  • Page 11: Installation

    2. Loosen the two (2) captive screws holding the end-cap cover and remove the cover. 3. Remove the two (2) screws attaching the terminal board (Legend 1 on Figure 1) and lift off the board. Figure 1 Rear End Cap (Wiring Side) Installation • • 3 X618 Rev 1298 V8400H-17-HT Housing Accessories...
  • Page 12: Rear End Cap (Component Side)

    8. Attach the heater plates to the four (4) studs on the bottom of the platform, using washers and nuts (Figure 9. Insert wires through the appropriate opening (Legend 2 on Figure 1). Wire to terminal board as shown in Figure 3. 4 • • Installation X618 Rev 1298 V8400H-17-HT Housing Accessories...
  • Page 13: Installing The V8400H-B Blower

    6. Align the legs of the blower with the mounting holes (Figure 2) and attach with four (4) 6 x 1/2-inch self- tapping pan head screws. 7. Route the wires through the appropriate opening (Legend 6 on Figure 1) and connect to the terminal board as shown in Figure 3. Installation • • 5 X618 Rev 1298 V8400H-17-HT Housing Accessories...
  • Page 14: Installing The V8400H-Def Defogger

    3. Wire to the terminal board as shown in Figure 3 and route wires through the housing as shown in Figure 5. Figure 5 Wiring the Defogger Through the Housing 4. Wrap the enclosed cable tie around all wires to secure. 6 • • Installation X618 Rev 1298 V8400H-17-HT Housing Accessories...
  • Page 15: Jumper Wire Assembly

    To provide power to the terminal board for accessories, install jumpers as shown in Figure 6. Figure 6 Jumper Wire Connections Note: The V8400H-H, V8400H-B, and V8400H-DEF accessories require no maintenance. Installation • • 7 X618 Rev 1298 V8400H-17-HT Housing Accessories...
  • Page 16: Shipping Instructions

    Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 17: Technical Information

    *These figures represent the conversion of 100% of the electrical energy to heat. Actual percentage of heat generated will be less and will vary from product to product. These figures are provided as an aid in determining the extent of cooling required for an installation. Technical Information • • 9 X618 Rev 1298 V8400H-17-HT Housing Accessories...