3gb/s and hd keyer, mixer with dual 2d dve (56 pages)
Summary of Contents for EVS Neuron NFR2000
Page 1
INSTALLATION AND SERVICE MANUAL Neuron NFR2000 Version 4.1 | March 2022...
Page 3
You will find the full list of addresses and phone numbers on the following webpage: http://www.evs.com/contact. User Manuals on EVS Website The latest version of the user manual, if any, and other user manuals on EVS products can be found at the EVS download center, on the following webpage: https://www.evs.com/en/download-area. Neuron NFR2000 | Disclaimer |...
NE JAMAIS remplacer un fusible par une valeur ou un type autre que ceux spécifiés. NEVER attempt to repair this product. If a problem occurs, contact your local EVS distributor. N'essayez JAMAIS de réparer ce produit. En cas de problème, contactez votre distributeur EVS local.
Page 6
This product complies with the requirements of the product family standards for audio, video, audio- visual entertainment and lighting control apparatus for professional use as mentioned below. Ce produit est conforme aux exigences des normes rélatives à la famille de produits d'équipements de contrôle d’éclairage, de spectacle audio, vidéo et audiovisuel à...
Page 7
Les chapitres contenant des actions d'entretien sont indiqués par un point d'exclamation. This equipment is only for use at altitudes not more than 2000m above sea level or equivalent. Cet équipement doit être utilisé uniquement à des altitudes inférieures à 2000m Neuron NFR2000 | UL |...
Page 8
au-dessus du niveau de la mer ou équivalentes. This equipment is only for use in non-tropical conditions or equivalent. Cet équipement ne doit pas être utilisé dans des conditions tropicales ou équivalentes. Caution, electric shock hazard. Attention, risque de choc électrique. Disconnect all power plugs before servicing this product.
In the Installation and Service Manual the icon has been added next to the text to highlight information on new and updated features. The changes in the NFR2000 manual are listed below: Dimensions diagrams • See section "Nominal Dimensions" on page 14. Neuron NFR2000 | What's New? |...
Observer les précautions de manipulation de dispositifs sensibles à l'électricité statique. Unpacking EVS has carefully inspected this product before shipment to ensure years of trouble free service. Upon reception, please make sure you: Check products for any visible damage that may have occurred during transit.
Page 14
Shipping Keep at least one set of original EVS packaging in case you need to return a product for servicing or replacement. If there is no original packaging available, please use your own packaging as long as it meets the following criteria: •...
EVS Cerebrum software will increase the system flexibility of one or more NFR2000 frames. We strongly advise you to use a remote personal computer or laptop PC installed with the EVS Cortex software, as this increases the ease of use and understanding of Neuron. This program can be downloaded from our website (https://mi-sftp.evs.com/) free of charge.
2.1. Product Description General Description The NFR2000 is a frame which can contain 2 processing cards. It is 1RU high. Together with the power supplies, the frame forms the base of the Neuron system. Main Features The NFR2000 includes the following features: •...
Page 17
INSTALLATION AND SERVICE MANUAL Broadcast Version In the Broadcast version, the power supplies and the I/O connectors are on the back. Front View Rear View Neuron NFR2000 | 2. Introduction to Neuron |...
2.2. LED Indicators LED Positions The NFR2000 frame has 4 LEDs: 1 for each power supply and 2 on the front plate. In the image below, the PSU LEDs are indicated in red and the Front LEDs are in green: The above image illustrates the broadcast version of the NFR2000 frame. On the datacenter version, front-plate LEDs (in green) are also present on the unit, but the PSU LEDs are on the back.
Please refer to section 1.2 "Unpacking and Shipping" on page 1 for more information about returning a product for servicing or replacement. Please contact your EVS dealer if parts are missing or damaged or when products on the packing list are missing.
3.4. Processing Module Installation and Replacement To insert the processing module into an NFR2000 frame, you should first determine whether the frame is built as a datacenter version (connections on the front) or a broadcast version (connections on the back). Once this is determined, slide in the processing module from the connector side until it cannot be pressed any further.
Airflow is reversed in the datacenter version (going from back to front). Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not Neuron NFR2000 | 3. Installation |...
Page 22
compromised. Please make sure there is sufficient space and airflow on the front, sides and back of the frames. When stacking frames, please do not block the air vents on the top of the frame, to prevent the unit from overheating. We strongly recommend leaving 1 RU space between frames. If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the ambient room temperature.
Page 25
DUT is 1 meter. Frames are placed one meter from the ground in a 19” rack of 47 RU. All unused space is closed with blind panels. NFR2000, Broadcast version, fully loaded 80 dB(A) (preliminary) NFR2000, Datacenter version, fully loaded 73 dB(A) (preliminary) Neuron NFR2000 | 4. Specifications |...