Electrical Connections

Make wiring connections to the unit as indicated on enclosed wiring diagram. As with all gas appliances using electrical power, this furnace shall
be connected into a permanently live electric circuit. It is recommended that furnace be provided with a separate "circuit protection device"
electric circuit. The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the National
Electrical Code, ANSI/NFPA 70 , if an external electrical source is utilized. The integrated furnace control is polarity sensitive. The hot leg
of the 120V power supply must be connected to the black power lead as indicated on the wiring diagram.
Refer to the SERVICE FACTS literature and unit wiring diagram attached to furnace.

Field Wiring

Single Stage
Thermostat
BK
W1
R
G
B
Y2
Y1
HP
O
32
FIELD WIRING DIAGRAM FOR L8V1 SINGLE STAGE
IFC
HEATING THERMOSTAT, SINGLE STAGE AC OR HEAT PUMP
Outdoor Unit
(No Transformer)
BK
HP
W1
R
HP
G
B
Y2
Y1
HP
O
NOTES:
1) HP = Wiring used for Heat Pump systems.
2) Remove Y1 - O jumper on IFC for HP systems.
3) Y1 and/or Y2 must connect from the thermostat to the
X2
IFC for proper airflow.
4) A/TCONT 824 thermostats do not require the use of X2.
5) Cut BK jumper when using PWM thermostat, in conjunction
R
with a relay panel, or with a humidistat.
B
Y2
Y1
O
18-CE15D1-1C-EN