QBC Diagnostics ParaLens Quick Start Manual

Fluorescence microscopy system luorescence microscopy system

Advertisement

Quick Links

SPECIFICATIONS

OptiLume Illuminator:
Input:
Output:
Environmental:
Dimensions and weight:
Compliance:
Power Supply:
Input:
Output:
Compliance:

REPLACEMENT PARTS

Catalog
424275
424273
424276
427751
427708
427707
427711
424278
427710
427712
427713
427714
QBC Diagnostics Inc.
200 Shadylane Drive
Philipsburg, Pennsylvania 16866 USA
814-342-6205 • www.qbcdiagnostics.com
4 – 24 VDC; 0.7 – 2.5 Amps
Center positive DC power connector
30lm, 470nm
Indoor or outdoor sheltered
1¼˝ Diameter × 3⅛ Long
(31.75 mm × 79.375 mm)
3.62 oz. (0.10254 kg )
EU MDD 93/42/EEC
100 – 240 V AC; 47 – 63 Hz, 0.4 A
9V DC, 1.4 A
UL, CE
Description
ParaLens Adapter - 40X Dry Objective
ParaLens Adapter - 60X Oil Objective
ParaLens Adapter - 100X Oil Objective
OptiLume Light Source
Immersion Oil
Screwdriver
Power Pack w/ Adapters
ParaViewer
QBC Malaria Test Starter Kit
OptiLume System Carrying Case
w/ Foam Insert
OptiLume System Carrying Case
w/o Foam Insert
Foam Insert for OptiLume System
Carrying Case
4277-060-032 Rev A
Fluorescence Microscopy System
Fluorescence Microscopy System
ParaLens
ParaLens
with OptiLume Light Source
with OptiLume Light Source

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ParaLens and is the answer not in the manual?

Questions and answers

Summary of Contents for QBC Diagnostics ParaLens

  • Page 1 Output: 9V DC, 1.4 A Compliance: UL, CE REPLACEMENT PARTS Catalog Description 424275 ParaLens Adapter - 40X Dry Objective 424273 ParaLens Adapter - 60X Oil Objective 424276 ParaLens Adapter - 100X Oil Objective 427751 OptiLume Light Source 427708 Immersion Oil...
  • Page 2 USE ONLY THE POWER PACK (p/n 427711) THAT IS SUPPLIED WITH THE PARALENS SYSTEM • Never open the ParaLens System – there are NO serviceable parts contained with the ParaLens Adapter or OptiLume Light Source. • Allow system to cool before cleaning and storage.
  • Page 3 When the ParaLens Fluorescence Microscopy System is connected to a power Standard Included Equipment ......2 source, it will be “ON”. The intensity knob (Item 3, Figure 2) on the ParaLens OptiLume Light Source controls the operating current and the light output of ParaLens Adapter System the LED.
  • Page 4 Continue until ParaLens Adapter is securely fastened to nosepiece of microscope. The ParaLens Adapter may be rotated to any desired position and secured at given location by tightening the set screw (Item 5) with provided ParaLens screwdriver. It is not necessary to tighten the set screw for the ParaLens to function properly.

Table of Contents