Table of contents KBR MWV measuring transducer adapter Table of contents Table of contents ..........3 Application ..........8 Disclaimer .............5 The following transducer types are available: .........8 Safety notes ............6 Installing the device ......8 Product liability ...........7 Connection diagram ......9 Disposal..............7 Dimensions .........
Page 4
Introduction Dear customer Thank you for choosing a KBR product. To familiarize yourself with the operation and configuration of the device, we recommend that you read this manual carefully. This way, you will be able to use of the entire range of functions that this high-quality product has to offer.
Introduction KBR MWV measuring transducer adapter This manual contains notes that must be observed for your personal safety and to prevent damage to the equipment. These notes are identifi ed by a warn- ing sign or information symbol, depending on the degree of hazard they warn about.
KBR MWV measuring transducer adapter Introduction Safety notes In order to prevent operating errors, handling of the device has been kept as simple as possible. This will enable you to use the device very quickly. Be sure to carefully read the following safety notes.
Devices that are faulty, obsolete or no longer used, must be properly disposed If required, we will dispose of the devices for you. Scope of delivery Included in the scope of delivery: Device KBR MWV measuring transducer adapter User manual including technical parameters ...
KBR MWV measuring transducer adapter Application With the measuring transducer adapters (zero-point creators), you can create a virtual low-impedance neutral point for the measuring device in a three-phase network without neutral conductor. In the 600 or 700-V version, you can also use it to adapt the measuring voltage to the measuring devices.
KBR MWV measuring transducer adapter CAUTION Protect the primary voltage with a back-up fuse. Include a disconnector or circuit-breaker in the electrical installation of the building. The disconnector must be close to the device and accessible to the user. It must be marked as an isolating switch for this device.
KBR MWV measuring transducer adapter Technical data Type 400 / 100 V – IEC Primary voltage: 400 V Ph-Ph Secondary voltage: 100 V Ph-Ph or 57.7 V Ph-Mp Power Max. 1 VA Housing DIN rail installation Weight Approx. 650 g Dimensions Approx.
Page 12
KBR Kompensationsanlagenbau GmbH www.kbr.de Am Kiefernschlag 7 P +49 (0) 9122 6373 - 0 D-91126 Schwabach, F +49 (0) 9122 6373 - 83 Germany E info@ kbr.de...