Download Print this page
Sealey VMA92.V2 Instructions
Sealey VMA92.V2 Instructions

Sealey VMA92.V2 Instructions

Heavy duty industrial wet & dry vacuum cleaner

Advertisement

Quick Links

Thank you for purchasing a Sealey cleaner. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A
Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected
by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.
and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty
item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is
damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer
insulation extends beyond the cable restraint and that the restraint is tight.
Double insulated products, which are always marked with this symbol
To rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure
that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket
with your electrician.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable.
1.2 .
GENERAL SAFETY
Disconnect the cleaner from the power source before servicing, changing accessories, or performing
other maintenance.
Maintain the machine in good condition. Use an authorised service agent.
Use only genuine accessories and parts. Unapproved parts or accessories can be dangerous and will
invalidate your warranty.
Keep machine clean, but DO NOT use harsh abrasives or solvents.
DO NOT place attachments close to your face and do not point hose at other persons or animals.
DO NOT use the cleaner on hot or glowing ashes, or cigarette ends.
DO NOT use the cleaner to vacuum inflammable, explosive or corrosive substances.
DO NOT vacuum hazardous dust (this may damage your health).
DO NOT vacuum soot, talcum power or other fine powders.
DO NOT dry vacuum without the dry filter firmly in place.
DO NOT wet vacuum with the dry filter in place, remove the dry filter, and optional dust bag, if fitted.
DO NOT leave the cleaner running unattended. Always turn off the power supply.
DO NOT clean the filter with solvents.
INSTRUCTIONS FOR:
HEAVY DUTY INDUSTRIAL
WET & DRY VACUUM CLEANER
VMA92.V2
MODEL No:
Original Language Version
Blue
Neutral
Wire
FUSE RATING 10 AMP
, are fitted with live (brown) and neutral (blue) wires only.
Yellow & Green
Earth Wire
Brown
Live
Wire
Cable
Restraint
VMA92.V2
Issue: 2 - 13/01/10

Advertisement

loading

Summary of Contents for Sealey VMA92.V2

  • Page 1 Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
  • Page 2 4.2. OPTIONAL DUST BAG Optional dust bags are available (Sealey model number AK291). The use of a dust bag will prolong the life of the cloth filter, keep the drum cleaner and make emptying easier. To fit a dust bag ensure that the inlet collar of the bag is pushed fully onto the inlet socket inside the drum. It is important to ensure that the dust bag is not filled to more than two thirds capacity.
  • Page 3 WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, www.sealey.co.uk...