Do you have a question about the Delta 2004 and is the answer not in the manual?
Questions and answers
Summary of Contents for ISKO KOCH Delta 2004
Page 1
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Delta 2004 KR-204-S Delta Evolution KR-214-S Owner's Manual KR-204-B/S Standing Frame with electric retractable belt (Modell „Delta 2004“) KR-214-B/S Standing Frame with electric retractable belt and tilting function (Model „Delta Evolution“) Stand: 10/2021 (Rev.
Page 2
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Dear Customer, We want to thank you for your trust by having purchased our product. Some of the remarkable features of the Standing Frame include quality, safety, easy handling, and modern design. For optimal use of this Standing Frame, we ask you and your assistant to carefully read through the owner's manual and keep it easily accessible.
Approaching the Standing Frame ....................13 Starting the Standing Frame ......................14 How to stand up using "DELTA 2004“ ................... 14 How to stand up using "DELTA Evolution“ ................15 What to do when the electrical supply is cut off ..............17 Suck/blow function for using the standing frame ..............
Page 4
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Recommended Accessories ....................... 19 Maintenance Intervals ....................... 20 Instructions for Disposal ......................21 Instruction Manual page 4 to 21 ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth...
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth 1 Note on the symbols used in these operating instructions This warning sign indicates all instructions that are important for safety. Non-observance can lead to accidents or injuries. Shows the manufacturer of the medical device...
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Safety Instructions The Frame should only be used by those trained to do so, ideally by a healthcare professional who is fully conversant with these instructions. Check clamping levers regularly for wear, do not over-tighten these as this may cause deterioration to chrome tubes.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Adjustable knee pad according to height and width Heel straps with Velcro fasteners Electric retractable belt to assist standing 4 Assembly information Basic information for assembly The standing frame should only be assembled by authorised personnel. The fuse protection on the installation side must not exceed 16A.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Description of the individual parts of the Standing Frame Instruction Manual page 8 to 21 ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth...
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth 5 Instructions for Adjustment All pre-adjustments need to be made without the user standing at the Standing Frame. Fine tuning adjustments can then be made with the user in position. Prior to using the Standing Frame with the electric belt rewinder, it is important to adjust the position of the knee pads, hip bar height and table height using measurements relevant to each user if necessary.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Back Pad (not included in standard extent of delivery) An assistant is necessary for using the back pad! The hip pads may be adjusted to the correct height by loosening the clamps on the main bar. It may be adjusted to the user´s midsection by loosening the clamps, pos.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth set so that when the user's trunk is vertical against the pad on the front of the tray, the knee is extended or very slightly flexed. Adjust the heel strap on the frame base by moving the heel strap to the location holes that help maintain this alignment through the body.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Sliding Tray There is a sliding tray interface option (factory fitted) for the Delta standing frame which allows the tray to be slid closer to the user once they are in a standing position.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Lifting Harness The user should put on the belt before approaching the Standing Frame. The belt should be fastened so that the bottom edge just touches the seat of the wheelchair. Then, the belt may be fastened around the lower abdomen.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth 7 Starting the Standing Frame Connect the power cable to a suitable supply and switch on the socket, the Frame is ready for use. The additional forced switch-off is released, as long as the emergency stop push button, pos. 1 (see chapter 4.2), is kept pressed.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth supporting the user. Release the lifting straps from the harness by depressing the red button on each buckle and pulling the two items apart. How to stand up using "DELTA Evolution“ The Standing Frame with tilting function facilitates easier access and a smoother lifting operation. Arm rails, knee support, and footboard are inclined towards the patient prior to standing up (see Pic.
Page 16
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Standing-up process Description handset Tilt the stander back by pressing the switch as indicated (right). Click in the two Lift Chords with the patient support harness fastened Tighten the Lift Chords; to this end, press the rope retract switch as indicated until the ropes are tightened, Please note the user has not yet begun to lift.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth What to do when the electrical supply is cut off If the event of a power failure whilst the electric retractable belt system is in use, it is necessary to get an assistant to help the user back into his/her wheelchair. Please note that the following instructions are intended for a right-handed assistant.
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth 8 Environmental conditions These conditions apply to both use and storage of the device Room temperature: 10°C to 45°C Air humidity: 30% to 75% Air pressure: 700hPa to 1060hPa 9 Technical Data...
In the case of products containing alcohol, there is a risk of explosion and fire when used over large areas. The use of unsuitable detergents and disinfectants can cause damage to the surface coating for which ISKO KOCH GmbH cannot be held liable. 13 Troubleshooting Problem...
Page 20
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth Suck/blow function KR-601-SB Table height adjustment from 0° to 30° KR-730 Sliding footboard (displacement approx. 10 cm) KR-720 Footboard height adjustment (only available with IK-KR-720) KR-721-X Upper body support (thorax support) Height 15 cm...
ISKO KOCH GmbH, Egerländer Str. 28, 95448 Bayreuth 16 Instructions for Disposal Disposal of the device and its accessories, if any, may only be carried out in accordance with waste segregation regulations! Please observe that all electrical components should be disposed of in accordance with legal guidelines.