Page 2 · 234B Series TEC TO-Can LaserMount User’s Manual Table of Contents Introduction ....................3 Installation and Use ................... 4 Configuring the Temperature Controller ..........10 Working with Thermistors ............... 10 TEC Lifetime .................... 12 Connector Pin-Outs ................13 Technical Specifications .................
234B Series TEC TO-Can LaserMount User’s Manual · Page 3 Introduction Thank you for choosing the 234B TEC TO-Can LaserMount from Arroyo Instruments. The 234B LaserMount is designed for high performance and long term use. The 234B LaserMount is a higher performance TO-can mount, similar to our smaller 224 LaserMount, but offering a much higher thermal capacity (up to 10W at 25°C), lower operating temperatures, and a much higher 3A higher laser current capacity.
Page 4 · 234B Series TEC TO-Can LaserMount User’s Manual Installation and Use Configuring the mount: Start by identifying the specific electrical configuration style of your device from the illustrations below. The switch settings for each style are illustrated on the following page. For two pin devices (style G), which have their pins at the 3 o’clock and 9 o’clock positions, the third switch must be placed in the N/C position.
Page 5
234B Series TEC TO-Can LaserMount User’s Manual · Page 5 LD Anode and PD Cathode Common Style A (or E) PD/LD PD / Common Cathode Style B (or H) PD/LD PD / LD Cathode & PD Anode Common Style C PD/LD PD / Common Anode...
Page 6
Connect to Laser Diode Driver and TEC Controller: Next, connect the 234B to your laser diode driver and temperature controller. NOTE Arroyo Instruments offers Laser and TEC cables designed to connect directly between our LaserSource and TECSource products. If you use your own cables, ensure the connections are properly made between the instrument and the mount, and that proper grounding techniques are used.
Page 7
234B Series TEC TO-Can LaserMount User’s Manual · Page 7 Mounting your device: Insert the device so that the common pin is the top or bottom pin, the isolated photodiode pin is on the left, and the isolated laser pin is on the right.
Page 8
Page 8 · 234B Series TEC TO-Can LaserMount User’s Manual When tightening the screws, do not over tighten, which may strip the threads. Do not tighten one side more than the other, as poor or uneven temperature control may result; the two pictures below show a correct and improper use of the diode clip: GOOD: Diode properly clamped, BAD: Diode improperly clamped,...
Page 9
234B Series TEC TO-Can LaserMount User’s Manual · Page 9 You may choose to install the cover. The cover is not required, but will improve the temperature stability of the mount. Depending on the type of the device, choose the appropriate clip to mount it: TO-5.6 and TO-9 clips TO-9 1mm offset clip 234B with diode loaded,...
234B. This will change the sensor settings, current limit, and fan settings to be appropriate for this mount. If you have an older Arroyo Instruments temperature controller that does not have this selection, there may be an upgrade available for your instrument, check with the factory for more information, or simply adjust the current limit to no more than the maximum current of the 234B.
Page 11
The coefficients for the BetaTHERM 10K3A1 thermistor are: A = 1.12924x10 B = 2.34108x10 C = 0.87755x10 These are the default coefficients for Arroyo Instruments temperature controllers, but can be changed in the Sensor menu, or by selecting the appropriate 234B mount from the Mount menu setting.
TEC more quickly. Mechanical stresses caused by uneven surfaces, uneven compression, or sheer or uneven loads. Arroyo Instruments mounts are designed to avoid these conditions, but can still be induced by customer loads in the final application.
234B Series TEC TO-Can LaserMount User’s Manual · Page 15 Thermal Capacity The maximum thermal load supported by the 234B depends on the ambient temperature and cold plate temperature, as shown by the graph below. The performance is based on an ambient temperature of 25°C, and actual performance will be improved or degraded if the ambient temperature is lower or higher, respectively.
Page 18
Page 18 · 234B Series TEC TO-Can LaserMount User’s Manual TO-9 1mm Offset Clip 234B with Standard Cover, Front View...
Page 19
234B Series TEC TO-Can LaserMount User’s Manual · Page 19 234B with 1mm Offset Cover, Front View 234B with Standard or 1mm Offset Covers, Side View...
Page 20
Page 20 · 234B Series TEC TO-Can LaserMount User’s Manual 234B with 234-C-02 Cover, Front View 234B with 234-C-02 Cover, Side View...
Electrostatic discharge and current spikes can be a significant cause of damage to laser diodes, but when proper precautions are taken, these risks can be greatly reduced or eliminated. Arroyo Instruments’ controllers offer state-of-art laser diode protection, but no instrument can fully shield the laser from damage.
User’s Manual · Page 23 Warranty Arroyo Instruments warrants this product to be free from defects in material and workmanship under normal use and service for a period of two (2) years from date of shipment except for the TEC elements. Arroyo Instruments warrants the Peltier (TEC) element to be free from defects in material and workmanship under normal use and service for a period of one (1) year from date of shipment.