IP CAMERA CONFIGURATION IN ENVIROMUX WEB INTERFACE

The IP cameras in the chart below can be monitored by the E-16D/5D/2D and be used to take snapshots and attach them to
alert messages sent to users in the E-16D/5D/2D.
The images that are attached will be at the default resolution for each camera:
Model
E-IPCAM-HNPO-P
E-IPCAM-WHNPT-V4
Materials Included:
Model
E-IPCAM-HNPO-P
E-IPCAM-DHNPO-V2P
E-IPCAM-WHNPT-V4
To configure the IP camera to capture this image, enter the indicated text in the "Image URL" box on the "Configure IP
Cameras" page of the ENVIROMUX Web Interface. Also add the URL Type, IP address, Username and Password as
indicated.
For E-IPCAM-HNPO-P:
Image URL: <IP ADDRESS>/onvifsnapshot/media_service/snapshot?channel=1&subtype=0
URL Type:
JPEG
Default IP Address: see instruction on page 6
Default Username:
admin
Default Password:
admin
For E-IPCAM-DHNPO-V2P
Image URL: <IP ADDRESS>/streaming/channels/1/picture
URL Type:
JPEG
Default IP Address: 192.168.1.64
Default Username:
admin
Default Password:
none- enter the password you assigned when you setup the camera
For E-IPCAM-WHNPT-V4:
Image URL: <IP ADDRESS>/onvifsnapshot/media_service/snapshot?channel=1&subtype=0
URL Type:
JPEG
Default IP Address:
see instruction on page 6
Default Username:
admin
Default Password:
admin
For all models, be sure to put a checkmark in "Enable HTTP Auth"..

Other ENVIROMUX Support

The IP cameras listed can all be monitored only (no snapshots) using the E-MICRO-TRHP. (The E-MICRO-TRHP requires
firmware version 3.11 or newer).
The E-IPCAM-WHNPT-V4 and E-IPCAM-HNPO-P can be used with the E-MINI-LXO and it can be monitored and take
snapshots to attach to alert messages.
Only the E-IPCAM-WHNPT-V4 and E-IPCAM-HNPO-P can be used with the E-1W model and it can only be monitored (no
snapshots).
See compatibility table on next page.
Default Resolution
1920x1080
1920X1080
1920x1080
Power Supply
100-240V @ 50/60Hz Input/ 12VDC 1A Output w/ country specific line cord
100-240V @ 50/60Hz Input/ 12VDC 1A Output w/ country specific adapter
100-240V @ 50/60Hz Input/ 5VDC 1.5A Output w/ country specific adapter
(if you change settings in the camera, you will have to change this.)
(if you change settings in the camera, you will have to change this.)
Current Firmware Version
v2.800.00AC001.0.R, Build Date: 2020-09-04
v5.4.5 build 170124
v2.800.0000000.1.R, Build Date: 2019-09-27
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E-IPCAM-HNPO-P and is the answer not in the manual?

Questions and answers

Summary of Contents for NTI E-IPCAM-HNPO-P

  • Page 1 The E-IPCAM-WHNPT-V4 and E-IPCAM-HNPO-P can be used with the E-MINI-LXO and it can be monitored and take snapshots to attach to alert messages. Only the E-IPCAM-WHNPT-V4 and E-IPCAM-HNPO-P can be used with the E-1W model and it can only be monitored (no snapshots).
  • Page 2 Note: To use the E-IPCAM-WHNPT-V4 or E-IPCAM-HNPO-P with the E-MINI-LXO, E-1W, E-MICRO-TRHP and for E-mailing snapshots on the E-xD, you must first disable ONVIF Authentication in the camera's software. See page 7. ENVIROMUX Model Compatiblity Model Monitoring Snapshots for alerts...
  • Page 3 Figure 3- E-MINI-LXO IP Camera configuration page Figure 4- E-1W IP Camera configuration page The E-MINI-LXO and E-1W do not support authentication. Only the E-IPCAM-WHNPT-V4 or E-IPCAM-HNPO-P can be used with them provided you first disable ONVIF Authentication in the camera's software.
  • Page 4 Access Individual Camera Settings E-IPCAM-DHNPO-V2P To access the E-IPCAM-DHNPO-V2P web interface to change its settings: 1. Connect the camera to a POE connected Ethernet cable to power it ON, or connect the supplied 12VDC power supply. The Ethernet cable must be connected to the same local network your PC is connected to. Note: By default, this camera obtains an IP address from a DHCP server on the local network.
  • Page 5 4. After the initial login and password assignment, the login screen will look like this. 5. Enter the username and assigned password. Then click “Login”. You now have access to all internal settings of the camera. Note: In order to attach camera images to email or save them on a USB flash drive, either upgrade the E-xD firmware to version 4.18 and above OR a change to this IP camera’s default settings will be needed (below).
  • Page 6 E-IPCAM-WHNPT-V4 and E-IPCAM-HNPO-P To access the E-IPCAM-WHNPT-V4 or E-IPCAM-HNPO-P web interface to change its settings: 1. Connect the AC adapter to the camera to power it ON. Wait 30 seconds. 2. Connect an Ethernet cable between the camera and an available port on a router (connected to your network), or directly to a PC.
  • Page 7 Note: To use the E-IPCAM-WHNPT-V4 or the E-IPCAM-HNPO-P with the E-MINI-LXO, E-1W, E-MICRO-TRHP and for E-mailing snapshots on the E-xD, you must first disable ONVIF Authentication in the camera's software. (ONVIF Authentication is enabled by default.) After changing the setting, click "Save".

This manual is also suitable for:

E-ipcam-dhnpo-v2pE-ipcam-whnpt-v4