Table of Contents

Advertisement

Quick Links

A-TAKT V-7HS
User Manual
PHOTO RESEARCH INC.
7279 William Barry Blvd.
North Syracuse, NY 13212-3349
Phone: (315) 701 --0678
FAX: (315) 701 -067 9
Email:
sales.pr@photoresearch.com
URL:
www.photoresearch.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PHOTO RESEARCH A-TAKT V-7HS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Jadak PHOTO RESEARCH A-TAKT V-7HS

  • Page 1 A-TAKT V-7HS User Manual PHOTO RESEARCH INC. 7279 William Barry Blvd. North Syracuse, NY 13212-3349 Phone: (315) 701 --0678 FAX: (315) 701 -067 9 Email: sales.pr@photoresearch.com URL: www.photoresearch.com...
  • Page 3 The information contained in this document is subject to change without notice. If there are any questions pertaining to the use of this system, contact JADAK. Jadak and Novanta shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this system.
  • Page 4 Customer Support PHOTO RESEARCH, Inc. has support services available to users in case of problems using the A-TAKT V-7HS. PHOTO RESEARCH, Inc. personnel are available from 8:00 AM to 5:00 PM (Eastern Time) Monday through Friday, except legal holidays, to aid in technical support. Call (315) 701-0678, FAX: (315) 701-0679 or e-mail: service.pr@photoresearch.com for instrument repair or calibration...
  • Page 5: Table Of Contents

    A-TAKT V-7HS User’s Manual Table of Contents Chapter - 1 Introduction ......................6 Standard Equipment ......................6 Chapter - 2 System overview ...................... 8 RS232 Connector ........................8 Mini USB 1.1 Connector ..................... 9 Power Connector ........................ 9 Connecting the AC Adapter ......................9 MS-75 Standard Objective Lens ....................
  • Page 6 A-TAKT V-7HS User’s Manual Installing the camera Viewer .................... 22 Running the Camera Viewer .................... 22 Adjusting the Image ......................23 Focusing the Image ......................24 Installing the USB Driver ......................24 Determining the COM: Port ....................25 Software Development Kit (SDK) ....................26 Class Documentation .........................
  • Page 7 A-TAKT V-7HS User’s Manual Int32 prDeviceUserCorrelationTable (string table, ref double brightness, ref double cieX, ref double cieY) ........................28 Int32 prDeviceEnableCorrelationTable (bool bTurnOn) ............ 28 Int32 prDeviceStartCamera (string viewerPath) ..............28 Int32 prDeviceStopCamera () .................... 28 int prUpdateFirmware (string FWFile) ................28 Int32 prDeviceGetMinExposure (ref Int32 minExposure) ..........
  • Page 8 A-TAKT V-7HS User’s Manual Int32 PR6xxComm.CommBase.prDeviceSerialNumber (ref string szSerialNumber) ..34 Int32 PR6xxComm.CommBase.prDeviceSetFrequency (Int16 synchFrequency) .... 34 Int32 PR6xxComm.CommBase.prDeviceSmartDark (bool bTurnOn) ......35 Int32 PR6xxComm.CommBase.prDeviceSpectralMeasure (ref string spectralData) ..35 Int32 PR6xxComm.CommBase.prDeviceStartCamera (string viewerPath) ...... 35 Int32 PR6xxComm.CommBase.prDeviceStopCamera () ..........36 Int32 PR6xxComm.CommBase.prDeviceTaktIndex (int index).........
  • Page 9 A-TAKT V-7HS User’s Manual Table of Figures 1 – A-TAKT V-7HS S ....................8 IGURE 2 - I/O P ....................8 IGURE ANEL ENLARGEMENT 3 - M -B USB ....................9 IGURE CONNECTOR 4 - MS-75 ....................10 IGURE OBJECTIVE LENS 5 –...
  • Page 10: Chapter - 1 Introduction

    Chapter 1 - IntroductionPR-730 / PR-735 Users Manual Chapter - 1 I NTRODUCTION The A-TAKT V-7HS is designed for high-speed in-line testing/verification of flat panel displays (FPD). It is a true spectroradiometer and consists of an objective lens, sampling aperture, diffraction grating, and 512 element, thermoelectrically cooled detector.
  • Page 11 Chapter 2 – System Overview...
  • Page 12: Chapter - 2 System Overview

    Chapter 2 – System Overview Chapter - 2 S YSTEM OVERVIEW CCD Camera I/F FIGURE 1 – A-TAKT V-7HS SIDE VIEW RS232 Connector Connector AC Adaptor Receptacle FIGURE 2 - I/O PANEL ENLARGEMENT RS232 C ONNECTOR...
  • Page 13: Mini Usb 1.1 Connector

    Chapter 2 – System Overview For applications requiring traditional RS232 communications, the RS232 is available. An RJ-12 connector is available on the V-7HS allowing the user to connect the instrument to the controller RS232 port using the included RJ-12 to DB-9 adapter. To Instrument To Adapter ...
  • Page 14: Standard Objective Lens

    Chapter 2 – System Overview MS-75 S TANDARD BJECTIVE ® If your A-TAKT V-7HS was equipped with the MS-75 objective lens, it is a 75mm f/2.8 MacroSpectar lens that focuses from 1:4 magnification (at 14” from the target) to infinity. This feature allows the instrument to be focused at different distances from the sample providing the ability to change the measured spot size.
  • Page 15: Removing The Objective Lens

    Chapter 2 – System Overview EMOVING THE BJECTIVE 1. Grasping the rear rubber ring (see Figure 4) turn the lens counter-clock-wise until the lens separates from the lens mount. NSTALLING THE BJECTIVE 1. Grasping the rear rubber ring (see Figure 4) turn the lens clock-wise until the lens seats on the lens mount.
  • Page 16: Chapter - 3 Theory Of Operation

    Chapter 3 – Theory of Operation Chapter - 3 T HEORY OF PERATION The A-TAKT V-7HS are true Spectroradiometers. It collects the optical radiation (light) through the objective lens. The signal then passes through the aperture (hole) in the aperture mirror to the diffraction grating (see Figure 6).
  • Page 17 Chapter 3 – Theory of Operation 512 detector array Incident light Diffracted light Input Slit Aperture Mirror Diffraction grating Objective Optical lens Camera radiation Viewer FIGURE 6 – V-7HS SPECTROMETER CONTROLLER Spectrometer FIGURE 7 - V-7HS BLOCK DIAGRAM The uncorrected or ‘raw’ spectrum is corrected using factors established during the factory calibration of the instrument.
  • Page 18 Chapter 3 – Theory of Operation...
  • Page 19 Chapter 3 – Theory of Operation Next, spectral correction factors are established using a continuous source with known intensities at each wavelength. These factors insure that the proper spectral power distribution (SPD) of the target is determined following a measurement, and that calculated values such as CIE Chromaticity, based on the measured spectral quantities, are accurately reported.
  • Page 20 Chapter 3 – Theory of Operation CIE XYZ Tristimulus and Photometric Values Where: X, Y, and Z are the three CIE Tristimulus values. X represents the red component, Y is the green component and Z is the blue component. Y also serves as the photometric value – when using the standard MS-75 lens, Y gives candelas / meter²...
  • Page 21: Chapter - 4 Basic Setup Procedures

    Chapter 4 – Basic Setup Procedures Chapter - 4 B ASIC ETUP ROCEDURES NTRODUCTION This section provides instructions and set-up procedures prior to making measurements with the A-TAKT V-7HS. For the location of components referred to in this section, please see Chapter 1 of this manual.
  • Page 22: Chapter - 5 Software

    Chapter 5 – Software Chapter - 5 S OFTWARE Included with your A-TAKT V-7HS is a CD containing a Firmware Updater, Camera Viewer, USB Driver Installer and the A-TAKT SDK files. FIGURE 9 - CD DIRECTORY CD F OLDER ESCRIPTIONS IRMWARE PDATER Contains FWInstaller.msi, firmware updater software installer.
  • Page 23: Sdk Folder Content Descriptions

    Chapter 5 – Software FIGURE 10 - SDK FOLDER CONTENTS SDK F OLDER ONTENT ESCRIPTIONS cppClient C++ sample console app to call SDK functions PR6xxComm SDK library DLL PR6xxCommClient C# sample console app to call SDK functions...
  • Page 24: Updating The Firmware

    Chapter 5 – Software PDATING THE IRMWARE If it is necessary to update the firmware for your A-TAKT instrument, it must be done from the PC. This is accomplished using the Firmware Updater application located on the CD. NSTALLING THE PDATER 1) Run the file FWInstaller.msi located on the CD in the Firmware Updater folder.
  • Page 25 Chapter 5 – Software 2) Click the ▼ icon in the Port field. Select the COM port assigned to the PR Instrument. The COM port can be found using Windows Device Manager. 3) Click Open to connect to the A-TAKT. 4) Click on Select Firmware File.
  • Page 26: A-Takt Camera Viewer

    Chapter 5 – Software A-TAKT C AMERA IEWER NSTALLING THE AMERA IEWER OFTWARE NSTALLING THE CAMERA IEWER 1) Launch the file ATaktCameraSetup.msi located on the CD in the PRICameraViewer folder. If you encounter a User Account Control message, click on Yes run the Installer. 2) Click next through the following screens to complete the installation.
  • Page 27: Figure 11 - Main Camera Viewer Screen

    Chapter 5 – Software FIGURE 11 - MAIN CAMERA VIEWER SCREEN Note the image of the measuring aperture in the center of the field of view. Adjusting the Image 1) Click on Camera Config to bring up the following screen: FIGURE 12 - CAMERA VIEWER CONTROL PANEL 2) Use the controls to adjust the quality of the image.
  • Page 28 Chapter 5 – Software Focusing the Image 1) If using a fixed focus lens, there is no need to focus the image if within the published focus range. 2) If using a variable focus lens such as the MS-75, adjust the lenses focus ring until the sample is in sharp focus.
  • Page 29 Chapter 5 – Software COM: P ETERMINING THE NOTE: The V-7HS must be powered up and connected to the PC for this procedure. After installing the USB driver, and before communicating with the V-7HS, use the following steps to determine the COM: port assigned by the driver to your V-7HS. 1.
  • Page 30 Chapter 5 – Software (SDK) OFTWARE EVELOPMENT LASS OCUMENTATION LASS EFERENCE The CommBase Class provides a high level software interface to the Photo Research family of spectrometers. UBLIC YPES enum UnitsType { UnitsType.ImperialUnits, UnitsType.MetricUnits } Selectors for set measurement units method enum SpeedMode { SpeedMode.SpeedNormal, SpeedMode.SpeedFast,...
  • Page 31 Chapter 5 – Software UBLIC EMBER UNCTIONS string prVersionInfo () Get SDK version information. int prOpenLogFile (String FilePath) Creates SDK level log file and starts logging process. int prDeviceOpen () prDeviceOpen Finds and opens PRI spectral device. Also reads maximum exposure time from detected instrument.
  • Page 32: Int32 Prdeviceusercorrelationtable (String Table, Ref Double Brightness, Ref Double Ciex, Ref Double Ciey)

    Chapter 5 – Software Int32 prDeviceSpectralMeasure (ref string spectralData) Take spectral measurement Int32 prDeviceGetTakt (ref int Takt1, ref int Takt2, ref int Takt3, ref int Takt4) Get previously configured TAKT table values. (These are saved in the SDK) Int32 prDeviceTaktTable (int Takt1, int Takt2, int Takt3, int Takt4) Set TAKT table using user provided values.
  • Page 33: Detailed Description

    Chapter 5 – Software ETAILED ESCRIPTION The CommBase Class provides a high level software interface to the Photo Research family of spectrometers. EMBER NUMERATION OCUMENTATION enum PR6xxComm.CommBase.DriverErrorCodes Additional error codes for problems detected by the SDK. Enumerator Success SDK operation succeeded. BadArguments An invalid argument was detected.
  • Page 34: Enum Pr6Xxcomm.commbase.taktlearnphases

    Chapter 5 – Software enum PR6xxComm.CommBase.TaktLearnPhases Enumeration of interactive phase or steps used to generate a synch frequency adjusted takt table. Enumerator GetFrequency Phase to get DUT synch frequency. Assumes DUT set to W255 / 50% back light. MaxWhite Phase to get DUT maximum white exposure time. Assumes DUT set to W255 / 100% back light.
  • Page 35: Int32 Pr6Xxcomm.commbase.prdeviceexposure (Int Msecs)

    Chapter 5 – Software Int32 PR6xxComm.CommBase.prDeviceExposure (int mSecs) Set exposure time for subsequent measurements. Parameters: mSecs Exposure time in milliseconds. If the argument is zero the instrument will run in adaptive mode. Returns: A Int32 instrument operation result code: 0 = success, negative number is error code Int32 PR6xxComm.CommBase.prDeviceFirmwareVersion (ref string szFirmwareVersion) prDeviceFirmwareVersion Gets the firmware version of the currently opened PRI spectral device...
  • Page 36: Int32 Pr6Xxcomm.commbase.prdevicegettakt (Ref Int Takt1, Ref Int Takt2, Ref Int Takt3, Ref Int Takt4)

    Chapter 5 – Software Int32 PR6xxComm.CommBase.prDeviceGetTakt (ref int Takt1, ref int Takt2, ref int Takt3, ref int Takt4) Get previously configured TAKT table values. (These are saved in the SDK). Parameters: Takt1 Last exposure time in microseconds for bright light/color levels Takt2 Last exposure time in microseconds for medium light/color levels Takt3...
  • Page 37: Int32 Pr6Xxcomm.commbase.prdevicelearnfreqadjustedtakt (Taktlearnphases Learnphase, Int Frequency)

    Chapter 5 – Software Int32 PR6xxComm.CommBase.prDeviceLearnFreqAdjustedTakt (TaktLearnPhases learnPhase, int frequency) Interactive method to use when determining TAKT table values for customer target. Each phase or pass requires that the DUT be set to a specified luminance/color level. Upon completion of all the required phases a takt table is generated and applied to the instrument.
  • Page 38: Int32 Pr6Xxcomm.commbase.prdeviceserialnumber (Ref String Szserialnumber)

    Chapter 5 – Software int PR6xxComm.CommBase.prDeviceOpen () prDeviceOpen Finds and opens PRI spectral device. Also reads maximum exposure time from detected instrument. Returns: 32 bit integer indicating the method completion status; 0 = success, -1 = failed to open device Int32 PR6xxComm.CommBase.prDeviceSerialNumber (ref string szSerialNumber) prDeviceSerialNumber Gets the serial number of the currently opened PRI spectral device.
  • Page 39: Int32 Pr6Xxcomm.commbase.prdevicesmartdark (Bool Bturnon)

    Chapter 5 – Software Int32 PR6xxComm.CommBase.prDeviceSmartDark (bool bTurnOn) Enable/disable mandatory capturing of a dark frame before each measurement. When this feature is enabled the spectrometer determines if a dark frame is required. Parameters: bTurnOn A boolean: true = smart dark on, false = smart dark off Returns: A Int32 instrument operation result code: 0 = success, negative number is error code Int32 PR6xxComm.CommBase.prDeviceSpectralMeasure (ref string spectralData)
  • Page 40: Int32 Pr6Xxcomm.commbase.prdevicestopcamera ()

    Chapter 5 – Software Int32 PR6xxComm.CommBase.prDeviceStopCamera () Kill instrument viewing camera application. Returns: Int32 PR6xxComm.CommBase.prDeviceTaktIndex (int index) Set TAKT table index for previously applied TAKT table. Parameters: index 0 = adaptive (instrument picks best fit value from tabel), 1-4 = use value at specified index Returns: A Int32 instrument operation result code: 0 = success, negative number is error code...
  • Page 41: Int32 Pr6Xxcomm.commbase.prdeviceusercorrelationtable (String Table, Ref Double Brightness, Ref Double Ciex, Ref Double Ciey)

    Chapter 5 – Software Int32 PR6xxComm.CommBase.prDeviceUserCorrelationTable (string table, ref double brightness, ref double cieX, ref double cieY) Provide instrument with user specified spectral correlation table. This table must be applied while the instrument is measuring the same light source used to generate the table. The application measurement will be executed as part of this procedure.
  • Page 42: String Pr6Xxcomm.commbase.prversioninfo ()

    Chapter 5 – Software string PR6xxComm.CommBase.prVersionInfo () Get SDK version information. Returns: String containing Assembly name, version, and copyright.
  • Page 43: Routine Maintenance

    Chapter 6 – Routine Maintenance OUTINE AINTENANCE The A-TAKT V-7HS has been designed to give long, trouble-free service requiring minimal routine maintenance. This section gives guidelines for insuring optimum service from your instrument. LEANING ENSES PTICAL CCESSORIES 1. Keep the V-7HS clean and dust-free. Store the instrument in a clean, dry environment, preferably in a storage case when not in use.
  • Page 44: Out-Of-Warranty Repair

    Chapter 6 – Routine Maintenance The instrument will be returned by a commercial surface transportation method of Photo Research's choice. If Air Freight or other rapid delivery is desired, the user should include a check or money order to cover the cost of return shipping, or contact Photo Research and supply a shipper account number (e.g.
  • Page 45: Chapter - 6 - Specifications

    Chapter - 6 PECIFICATIONS ENERAL PECIFICATIONS Detectors Cooled Detector Standard Aperture 1.25° Fixed Focus 50 mm Objective Lenses Variable Focus 75 mm Custom (contact factory) Standard Bandwidth 2 nm Luminance Range for 0.001 to 600 cd/m White LED Total Cycle time for 250 ms @ 0.5 cd/m Illuminant A Luminance Accuracy...
  • Page 46: A-Takt V-7Hs Sample Area Coverage

    1, 2 A-TAKT V-7HS S AMPLE OVERAGE Aperture Objective Lens Spot Size 1.5 1.25 1 0.5° 299.1 299.1 316.9 316.9 335.2 335.2 353.5 353.5 FF-50 371.9 371.9 299.0 335.2 390.3 390.3 310.4 350.1 396.3 396.3 364.4 451.1 451.1 450.9 505.3 588.0 588.0 MS-75...
  • Page 47 Front Mounting Hole FIGURE 13 - A-TKT V-7HS ENVELOPE DRAWING...

Table of Contents