CARGO COMPARTMENT TEMPERATURE CONTROL - ADJUSTMENT/TEST
1.
Operational Test
WARNING : BEFORE POWER IS SUPPLIED TO THE AIRCRAFT, MAKE CERTAIN
THAT ELECTRICAL CIRCUITS UPON WHICH WORK IS IN PROGRESS
ARE ISOLATED.
A.
Reason for the Job
(1)
To check operation of the cargo compartment temperature
control system and interface with smoke detection system.
B.
Equipment and Materials
ITEM
(1)
Referenced Procedures
-
(Ref. 24-41-00, P. Block 301 )
-
(Ref. 33-17-00, P. Block 501 )
-
(Ref. 31-51-00, P. Block 201 )
FED 401-405,407-414,423-430,443,445
POST SB 31-2059 for A/C 401-405,407-414,423-430,443,445
Referenced Procedures
-
(Ref. 24-41-00, P. Block 301 )
-
(Ref. 32-00-00, P. Block 501 )
-
(Ref. 33-17-00, P. Block 501 )
-
(Ref. 31-51-00, P. Block 201 )
P.Blk EFFECTIVITY: FED ALL
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
DESIGNATION
Electrical Ground Power Unit - 3-
Phase,
115/200 V, 400 Hz
AC External Power Control
Memorized Fault Annunciators
ECAM Sxstem
AC External Power Control
Landing Gear - General
Memorized Fault Annunciators
ECAM System
21-64-00-05
Page 1 of 106
JUN 01/2012

Advertisement

loading

Summary of Contents for FedEx A310-200 AMM

  • Page 1 (Ref. 33-17-00, P. Block 501 ) ECAM System (Ref. 31-51-00, P. Block 201 ) 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 1 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 2 FED 416-422,453-499 125VU AIR BLEED & COMPT TEMP/CARGO 37HN 504/G62 COMPT EXTRACT FANS/BULK 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 2 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 3 LIGHTING/ANN LT/TEST/MAN 902/T89 129VU LIGHTING/ANN LT/TEST/MAN 902/T90 129VU LIGHTING/ANN LT/TEST/AUTO 153LP 902/T91 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 3 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 4 On maintenance panel 472VU: ANN LT toggle switch 2WB is in READ position. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 4 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 5 R ECAM display - AIR COND page, is between H and C, 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 5 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 6 On maintenance panel 472VU: - check that BULK/CARGO MFA does not come on. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 6 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 7 H and C, then release selector switch. 2. On circuit breaker panel 125VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 7 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 8 - isolation valve closed, - isolation valve color : amber. On maintenance panel 472VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 8 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 9 2. On circuit breaker panel 125VU: - at location H65 open circuit breaker 5HN. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 9 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 10 Position 10 - Output of bridge is checked. Position 11 - Output of bridge is checked. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 10 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 11 1. At rack 91VU, on APU and pack temp On APU and pack temp demand demand controller 37HK: controller 37HK: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 11 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 12 GO or NO GO light comes on. NOTE : A NO GO light shows a failure 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 12 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 13 - at location H65 close circuit breaker 5HN. - (at location H63 close circuit breaker 43HN). 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 13 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 14 - (at location H63 open circuit breaker 43HN). 3. On BULK CARGO (FWD CARGO) compt 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 14 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 15 Position 9 - Overrides bridge output to produce a 'nulled' output. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 15 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 16 - rotate and hold BULK CARGO - hot trim air valve flap position 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 16 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 17 On R ECAM display - AIR COND page: - cold air valve flap position 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 17 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 18 On COMPT TEMP panel 437VU: BULK CARGO temperature selector switch 14HN is in MAN position. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 18 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 19 VALVE) pushbutton switch 6HN (52HN) is pressed in. On maintenance panel 472VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 19 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 20 - release BULK/LOOP B push- - OFF legend comes on. button switch 26WH. On WLDP: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 20 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 21 - place CARGO COMPT/LOOP TEST SEL toggle switch 48WH to LOOP A position. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 21 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 22 - release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 22 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 23 - isolation valve opens and color changes to green. - trim air valve flap position arrow 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 23 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 24 On L ECAM display: LOOP BULK COMPT LOOP B OFF disappears. FED 453-454,456-499 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 24 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 25 - TEST legend off PTT pushbutton selector switch 16WA to CARGO switch 52WA comes on. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 25 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 26 - trim air valve flap position arrow moves to position C. On L ECAM display: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 26 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 27 On COMPT TEMP panel 437VU: - reset BULK CARGO/ISOL VALVE - after isolation valve opens, 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 27 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 28 POST SB 31-2035 for A/C 423-435,443,445,453-499 POST SB 31-2059 for A/C 423-430,443,445 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 28 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 29 - hot trim air valve opens and temp selector switch 14HN remains stationary, color: green. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 29 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 30 25WH (21WH) legend come on. On WLDP: - SMOKE warning light flashes. In flight compartment: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 30 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 31 - BULK/SMOKE (FWD/SMOKE) red warning light and LOOP A legend go off. On WLDP: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 31 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 32 - ON legend comes on. 80HN (78HN). On L ECAM display: MEMO 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 32 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 33 25WH (21WH) come on. On WLDP: - SMOKE warning light flashes. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 33 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 34 - BULK/SMOKE (FWD/SMOKE) warning light and LOOP A legend go off. On WLDP: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 34 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 35 - TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 35 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 36 - cold trim air valve flap position arrow and scale disappear. *Before SB 31-2035 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 36 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 37 R ECAM display - AIR COND page, is at least half opened, 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 37 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 38 (FWD CARGO/ISOL VALVE) push- button switch 6HN (52HN) FAULT legend comes on. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 38 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 39 - SMOKE warning light goes off. In flight compartment: - repetitive chime stops. On L ECAM display: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 39 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 40 On L ECAM display: MEMO BULK CARGO COOLING ON (FWD CARGO COOLING ON) appears. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 40 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 41 - repetitive chime sounds. On COMPT TEMP panel 437VU: - BULK CARGO/ISOL VALVE (FWD CARGO/ 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 41 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 42 LOOP A legend go off. On WLDP: - SMOKE warning light goes off. In flight compartment: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 42 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 43 - TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off. to NORM/FLT position. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 43 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 44 1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 44 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 45 - rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 45 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 46 6HN (52HN) FAULT legend comes on and then goes off. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 46 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 47 On WLDP: - SMOKE warning light goes off. In flight compartment: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 47 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 48 - BULK/CARGO (FWD/CARGO) MFA 8HN (57HN) remains on. 6. On maintenance panel 472VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 48 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 49 CARGO) temp selector switch position arrow remains 14HN (53HN) when cold trim stationary. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 49 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 50 - cold trim air valve flap position arrow moves to 10 o'clock (closed) position. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 50 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 51 BULK CARGO COMPT SMOKE (FWD CARGO COMPT SMOKE) - AGENT 1 - DISCH 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 51 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 52 13. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 52 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 53 1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 53 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 54 - rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 54 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 55 VALVE (FWD CARGO/ISOL VALVE) pushbutton switch 6HN (52HN) legend comes on and then goes off. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 55 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 56 - SMOKE warning light goes off. In flight compartment: - repetitive chime stops. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 56 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 57 - press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA goes switch 20WB. off and remains off. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 57 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 58 9. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 58 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 59 10 o'clock (closed) position. On L ECAM display: SMOKE 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 59 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 60 On COMPT TEMP panel 437VU: - reset BULK CARGO/ISOL VALVE - for duration of isolation valve 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 60 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 61 13. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU: 433VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 61 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 62 1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU: 433VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 62 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 63 - TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA comes on. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 63 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 64 On R ECAM display - AIR COND page: - isolation valve closes and color changes to amber. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 64 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 65 BULK CARGO COMPT SMOKE (FWD CARGO COMPT SMOKE) - AGENT 1 - DISCH 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 65 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 66 - cold trim air valve flap position arrow with scale appears. 7. On COMPT TEMP panel 437VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 66 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 67 (52HN) FAULT legend comes on. On R ECAM display - AIR COND page: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 67 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 68 - repetitive chime stops. On L ECAM display: SMOKE BULK CARGO COMPT SMOKE 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 68 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 69 - press BULK/LOOP B (FWD/ - OFF legend goes off. LOOP B) pushbutton switch On WLDP: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 69 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 70 - OFF legend comes on. pushbutton switch 26WH (22WH). On main instrument panels 3VU and 5VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 70 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 71 COMPT selector switch 16WA switch 52WA comes on. to CARGO COMPT/BULK (CARGO COMPT/FWD/1) position. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 71 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 72 - hot trim air valve flap position arrow moves to position C. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 72 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 73 BULK CARGO COMPT SMOKE (FWD CARGO COMPT SMOKE) - LDG ELEVATION - 10,000 FT disappears. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 73 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 74 - hot trim air valve flap position (FWD CARGO) temp selector arrow remains at C and cold 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 74 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 75 On R ECAM display - AIR COND page: - isolation valve closes and 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 75 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 76 - repetitive chime stops. On L ECAM display: SMOKE BULK CARGO COMPT SMOKE 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 76 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 77 LOOP B) pushbutton switch On main instrument panels 3VU 26WH (22WH). and 5VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 77 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 78 On main instrument panels 3VU and 5VU: - MASTER/CAUTION lights come on. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 78 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 79 COMPT selector switch 16WA switch 52WA comes on. to CARGO COMPT/BULK (CARGO COMPT/FWD/1) position. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 79 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 80 - hot trim air valve flap position arrow moves to position C. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 80 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 81 5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 81 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 82 - hot trim air valve flap position (FWD CARGO) temp selector arrow remains at C and cold 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 82 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 83 On R ECAM display - AIR COND page: - isolation valve closes and 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 83 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 84 On L ECAM display: SMOKE BULK CARGO COMPT SMOKE (FWD CARGO COMPT SMOKE) 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 84 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 85 LOOP B) pushbutton switch On main instrument panels 3VU 26WH (22WH). and 5VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 85 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 86 NOTE : Setting the A/C to simulated FLT CONFIG (Ref. 32-00-00, P. Block 501), the ECAM SMOKE warning will include LAND ASAP for second priority 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 86 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 87 - AFT & BULK/SMOKE (FWD/SMOKE) red warning light 38WH (39WH) comes on. In flight compartment: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 87 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 88 On CARGO COMPT SMOKE DET panel 433VU: switch. - AFT & BULK/SMOKE (FWD/SMOKE) red warning light goes off. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 88 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 89 On CARGO COOL panel 444VU: - press BULK (FWD) pushbutton - ON legend comes on. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 89 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 90 On CARGO COMPT SMOKE DET panel 433VU, - press and hold PTT pushbutton after approx. 2-3 second delay: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 90 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 91 AFT & BULK CARGO COMPT SMOKE (FWD CARGO COMPT SMOKE) - LDG ELEVATION - 10,000 FT 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 91 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 92 On R ECAM display - AIR COND page: - isolation valve opens and 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 92 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 93 COMPT selector switch 16WA legend goes off. to NORM/FLT position. FED 413-414 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 93 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 94 On CARGO COMPT SMOKE DET panel 433VU, switch 52WA. after 2-3 second delay: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 94 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 95 - hot trim air valve flap position arrow moves to position C. On L ECAM display: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 95 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 96 On COMPT TEMP panel 437VU: - reset BULK CARGO/ISOL VALVE - for duration of isolation valve 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 96 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 97 On L ECAM display: MEMO BULK CARGO COOLING ON (FWD CARGO COOLING ON) appears. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 97 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 98 On WLDP: - SMOKE warning light flashes. On COMPT TEMP panel 437VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 98 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 99 - release PTT pushbutton On CARGO COMP SMOKE DET panel 433VU: 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 99 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 100 On R ECAM display - AIR COND page: - isolation valve opens and color changes to green. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 100 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 101 - PTT pushbutton switch 52WA COMPT selector switch TEST legend goes off. 16WA to NORM/FLT position. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 101 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 102 - rotate ELEC COMPT & CARGO COMPT - TEST legend off PTT pushbutton 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 102 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 103 - trim air valve flap position arrow moves to position C. 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 103 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 104 - after isolation valve opens, pushbutton switch 6HN. ISOL VALVE pushbutton switch 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 104 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 105 On L ECAM display: LOOP BULK COMPT LOOP B OFF disappears. FED 416-422,453-499 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 105 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
  • Page 106 (Ref. 24-41-00, P. Block 301 ) . 21-64-00-05 P.Blk EFFECTIVITY: FED ALL Page 106 of 106 Printed - Date: 12/11/12 Time: JUN 01/2012 Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.