www.intertec.info 1 General .................................. 3 2 Use ................................... 3 3 Special conditions for safe use.......................... 3 4 Explanation of symbols for warnings and signal words .................. 3 5 Safety information .............................. 4 6 Technical Data ................................ 4 7 Installation................................ 4 8 Connection................................
Operating Instructions SL FLATTHERM DC.A General GB 50257-2014: Code for construction and acceptance of electric equipment on fire and explosion hazard These operating instructions describe the safe and electrical equipment installation engineering proper way to work with the device. The safety GB 12476.2-2010: Electrical apparatus for use in the...
Operating Instructions SL FLATTHERM DC.A Profile type "P" Height x 220 x 200 x 30 NOTICE Width x Depth NOTE INFO It is essential to pay attention to this safety advice as you You will find the precise technical data for your may otherwise incur material damage.
Operating Instructions SL FLATTHERM DC.A The connection cable must be permanently installed up Connection to the inlet into the on-site junction box, taking the permissible bending radius = 5 x outer diameter into INFO consideration. The device may only be connected up and secured by a trained person, taking into account the "rated voltage"...
Operating Instructions SL FLATTHERM DC.A Junction Junction box Option AM Option AM Heater Heater bn=brown bu=blue ye/gn=yellow/green bk=black gy=grey bn=brown bl=blue ye/gn=yellow/green bk=black gy=grey Illustration 4: SL...THERM with TAE Illustration 5: SL...THERM with TS Commissioning If the heater is installed in accordance with the notes in the Installation [}Page ...
Operating Instructions SL FLATTHERM DC.A Functional and safety test intervals can be freely NOTICE selected by the operator in accordance with the applicable regulations. Environmental damage may be caused if Repairs may only be carried out by the manufacturer in disposed of incorrectly! the factory.
Operating Instructions SL FLATTHERM DC.A If the information contained in this instruction manual will find more detailed information should not be sufficient in any way, then INTERTEC manufacturer warranty from INTERTEC for heating would be glad to be at your disposal to provide further systems and accessories.
Page 9
Operating Instructions SL FLATTHERM DC.A 雹) 中国国家强制性产品认证证书 邑 SiTiiAs Worldwide Access 证书编号:2020322312003002 lntertec Hess_ GmbH 认证委托人名 称: Schroep I erstrasse 37, 85053, I ngo I stadt, Germany 认证委托人地 址: lntertec Hess GmbH 生 产者名 称: 生 产者地 址: Schroep I erstrasse 37, 85053, I ngo I stadt, Germany 生产企业名称:...
Need help?
Do you have a question about the SL FLATTHERM DC.A and is the answer not in the manual?
Questions and answers