Page 1
AUTOMATIC ABOVE-GROUND COVER CONTURA - L TECHNICAL INSTRUCTIONS Installation / Use / Cleaning / Maintenance / Safety advice...
Page 2
NOTICE TO BE GIVEN TO THE USER AFTER INSTALLATION IS COMPLETE PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE. Automatic motorised above ground safety cover using either mains electricity power. The opening or closure operation requires about 2 minutes for one person and about 3 minutes to lock or unlock the attachment kits.
Page 3
The roller: 48 cm 32 cm at the shaft 21 cm 41 cm - The motor (compliant with electric standards) is located in the tube and can be accessed from the exterior of the terminal. - Adjustment of the “mechanical automatic stop” locking the cover in place once it has been fully unrolled or rolled, is done directly on the motor.
TOOLS n°10 n°13 n° 17 Ø8 - 12 ASSEMBLY INSTRUCTIONS 3 hours PACKING LIST e.g. - for a 4 x 8 m pool 1 0.80 x 0.60 x 0.55 pallet —- 40kg 1 4.30 x 0.20 m pack —– 25 kg 4 5 x 0.25 x 0.20 m packs —–...
Instructions before installation Remember to have a sheath D + 6 cm fitted to connect the electric control box and the motor terminal. see positioning rules 1 page 7 D = (measurement between the terminal - pool width) / 2 ASSEMBLY / POSITIONING / FIXTURE Install the adjustment screw...
Page 7
Assembly motor side Position 1 Depending on the pool corners and the fastener kits on the roller side Sharp corner Rounded corners or cut-off corners Max. = 60 cm...
Page 8
Position 2 centre of the width motor side 5 mm 5 mm...
Page 9
Levelling ground Before fixing, check that there is an operating gap of 5 mm on each side. (see “positioning 2” previous page) nr.17 Ø12 Fix the adjustment bar 5 mm...
ASSEMBLING THE MOTOR n°10 Make small rotating movements with the motor to ease its fitting.
Page 12
WIRING - ELECTRIC VERSION - WI-KEY The electric control box must be fitted in a dry room. The installation must comply with the NF C15-100 standard and et CEI 60364 (Last applicable version) ask your electrician for advice or contact your electricity provider. All our control boxes use a 230 Volt single phase (50Hz) power supply.
Page 13
WIRING - ELECTRIC VERSION The electric control box must be fitted in a dry room. The installation must comply with the NF C15-100 standard and et CEI 60364 (Last applicable version) ask your electrician for advice or contact your electricity provider. All our control boxes use a 230 Volt single phase (50Hz) power supply.
Page 14
WI-KEY INSTALLING THE CONTROL BOX red / green flashing = emitter locked Emitter unlocking procedure see «page 23» The emitter must be located outside volume 0. The distance between the emitter and the receiver must not exceed: - 50 m in an obstacle-free zone. - 25 m behind a basic wall.
COVER INSTALLATION Make sure the slats are in the right direction Roller water 35 cm If necessary, cut the sides to ease skid the passage of the strap cover and avoid rubbing Slat assembly By clipping “CLICK” along the whole length of the slat Repeat the movement until all the slats are completely clipped together By sliding...
Page 16
Assembly of the strap between the cover and the tube notch skid assembly The skids are used to orient the cover at the start of closure. The holes are drilled at the factory.
Page 17
ADJUST THE AUTOMATIC STOPS Checking the order logic Pool closure If the command logic is not correct, reverse wires 1 and 2 on the motor output. (see wiring diagram) Pool opening Adjustment Turning in the +, direction will increase the extension of the cover Turning in the -, direction will reduce the extension of the cover...
Page 18
LOCKING KITS The position of the fastener kits on the cover is indicated on the drawings shipped with the slats. All changes to the positioning of the kits must comply with the rules given below. For other cases please contact us. Positioning rules With With side...
Page 19
PUSH-LOCK INSTALLATION A water level regulator is mandatory Insert mounted model Inserted For concrete and panel pools part Hollow white Ø16 washer 5 cm mini VBA TF Z pozi stainless steel A4 Ø6 x 60 wood screw Acceptable limit of level variation 50 mm water level...
Page 20
ALWAYS KEEP AN EYE ON THE POOL DURING OPENING OR CLOSING OPERATIONS. ALWAYS CHECK THAT THE POOL WATER LEVEL IS CONSTANT AND COMPLIANT WITH THE RECOMMENDATIONS ON THE INSTRUCTIONS - It is imperative not to halt the cover in an intermediate position, this can cause the risk of jamming a bather’s body under the cover casing, if a bather uses the pool.
WIKEY Locking Closure LOCKING THE WI-KEY • Press on for more than 3 seconds until the pilot flashes = system locked m loc Pilot UNLOCKING THE WI-KEY • Press and keep it pressed. • At the same time: successively press same tim the following 3 keys: : •...
Page 22
- To ensure optimum safety and the correct operation of the roller, always check that the level of the water in the pool rema- ins constant and compliant with the manufacturer’s recommendations. (For further comfort, use an overflow and a level regulator). - When the level is too high it is caused by the overflow being blocked by leaves or other debris.
Pairing -- delivered pre-paired receiver Pilot Press «STOP» and, without releasing it, press «O» for more than 3 seconds OK when the «pilot» flashes green. STOP an emitter must be paired within the next 30 seconds. emitter Press «STOP» and, without releasing it, press «O» for more than 3 seconds OK when the «pilot»...
Page 24
EAR CUSTOMERS HANK YOU FOR CHOOSING A AUTOMATIC COVER LEASE READ THE INSTRUCTIONS BELOW CAREFULLY ·P OOLS CAN BE A SERIOUS DANGER FOR CHILDREN ROWNING CAN HAPPEN QUICKLY S A F E T Y A D V I C E HEN CHILDREN ARE AROUND THE POOL THIS REQUIRES YOUR CONSTANT VIGILANCE AND ACTIVE SUPERVISION EVEN IF THEY CAN SWIM...