  • Page 1 User Manual LED-528 Etung Technology Co. Ltd 305 Gengfang Plaza, Jia 13 Huayuan Road, Haidian Dist. Beijing TEL:4008-909-611 FAX:010-64857815 Website: www.etungtech.com.cn Copyright © 2005-2015 ALL RIGHTS RESERVED...
  • Page 2: Table Of Contents

    Device Configurations ........................8 Configurations ........................9 2.1.1 Preparation ......................9 2.1.2 Configuring LED-528 ..................... 9 2.1.2.1 Add Terminal to the User via WEBLED .............. 10 2.1.2.2 Add Terminal to the User via Configuration Software ......... 11 Configuration Parameters....................13 Restore to default ......................
  • Page 3: Product Introduction

    Technical Advantages Typical Usecases 1.1 Brief Introduction LED-528 is a creative wireless LED combo terminal for LED information deployment that is made by eTung. It implements the integration of GPRS wireless communication model and LED controller model, and has better price performance so that it can greatly reduce device procurement cost for projects of LED remote information deployment.
  • Page 4: Product Outlook

    EtungTech LED-528 User Manual 1.2 Product Outlook Figure 1-1: Product architecture 1.3 Standard Accessories Figure 1-2 GSM acetabulum antenna Figure 1-3: 9-pin and 9-hole direct serial line...
  • Page 5: Dimensions

    WEBLED server Figure 1-5: LED-528 working mechanism LED-528 is directly attached to LED display with 08 pin or 12 pin interface. And it connects eTung's WEBLED server (customer can build its own server based on requirement) in the internet via GPRS wireless network. In order to...
  • Page 6: Capability Parameters

    1.6.3 Serial Port Definition Type RS-232 Definition RXD(out) TXD(in) Table 1-2: LED-528 serial port pin definition Attention: LED-528 serial port is used only to configure or update the model, and it cannot be used to connect PC and publish information.
  • Page 7: Technical Advantages

     Support program copy, save and load  Built-in 16 and 32 lattice character set in Chinese and English  Information can be sent to LED-528 via point to point, point to multipoint, multipoint to point and multipoint to multipoint ...
  • Page 8: Typical Usecases

    Device connecting into to WEBLED server WEBLED server WEBLED server Figure 1-6: Publish general information Figure 1-7: Publish special information with LED-528 customized software package 2 Device Configurations This chapter introduces how to use LED-528 and related parameters. Configurations Parameters...
  • Page 9: Configurations

    Firmware Update Remote Configurations 2.1 Configurations 2.1.1 Preparation  Serial line used to connect LED-528 with PC or user devices  GSM Antenna  Power Adapter  one SIM card, either from China Mobile or China Unicom, that applies GPRS and can access internet directly via NET 2.1.2 Configuring LED-528...
  • Page 10: Add Terminal To The User Via Webled

    EtungTech LED-528 User Manual Figure 2-2 Register username  After registration, contact eTung technical support by phone call (4008-909-611) to open the account. After that there are two ways to add the device to the user registered before. 2.1.2.1 Add Terminal to the User via WEBLED ...
  • Page 11: Add Terminal To The User Via Configuration Software

    (for detail please refers to the appendix). Figure 2-5 Add terminal complete 2.1.2.2 Add Terminal to the User via Configuration Software  Connect LED-528 with PC via 9-pin 9-hole serial line.
  • Page 12 "Settings", select the serial port that is used to configure LED-528, then click “OK”. Figure 2-6 Setting serial port  Click "Start Config" based on the prompt, and power on LED-528 quickly within 30 seconds; when the information about LED-528 model appears, press Enter.
  • Page 13: Configuration Parameters

    2.2 Configuration Parameters The first two items in the configuration menu have default server domain da.wuxianled.com and port 8888. They are the public server address and port provided by eTung. If the user builds its own server, then configure its own...
  • Page 14 EtungTech LED-528 User Manual server address and port accordingly. Figure 2-10 Configure domain and port Configuration Menu Item Description RESTORE THE DEFAULT Configure to restore to default or not SETTINGS[Y/N](N) 1) MSERVER DN/IP Address Configure data center IP address or domain da.wuxianled.com...
  • Page 15: Restore To Default

    Table 2-1: Details of configuration parameters 2.3 Restore to default According to the description of "Configuring LED-528", after entering LED-528 configuration interface, the first item is "RESTORE THE DEFAULT SETTINGS" option, input "Y" and press Enter, then the configuration will be restored to default.
  • Page 16 EtungTech LED-528 User Manual LED-528 with PC via 9-pin 9-hole serial line, run LED-528 configuration executable, and set the serial port used to update LED-528.  Click "Select File", and then select the file (.bin) to update, and click "Open".
  • Page 17: Remote Configurations

    Figure 2-14: Update complete 2.5 Remote Configurations SMS or AT commands can be used on LED-528 to remotely modify the IP address and port of the data center. Details are described below one by one: Use SMS to remotely modify IP address and port within LED-528.
  • Page 18 After that click button "Send", if all operations are correct, in the list of "CMD Response" at the right part, an "OK" will appear. Then LED-528 will be offline from this mServer, and connect to the new data center and port.
  • Page 19 EtungTech LED-528 User Manual Other AT commands used on LED-528: AT+SMSPING= PHONE_NUM ASK DTU to send an SMS to PHONE_NUM, with contents as DTU's IMEI. For example: AT+SMSPING=13651078461 AT+SMSZHUANFA=txt,info_src,dest Ask DTU to send an SMS with content "txt"( characters in English and digits only) to info_src, then forward the reply to dest.
  • Page 20: Appendix: Usecase Of Webled Publishing Program

    EtungTech LED-528 User Manual Appendix: Usecase of WEBLED Publishing Program Step 1: Configure LED-528 Refer the description in chapter 2.1 "Configurations". Step 2: Login WEBLED Login website http://da.wuxianled.com with the username that has been registered and open. Figure Appendix 1-1: Login Combo terminal WEBLED Step 3: Set Display Parameters Select the terminal.
  • Page 21 EtungTech LED-528 User Manual Figure Appendix 1-2: Select terminal Click "Screen Parameter Configuring" under "Terminal Control". Figure Appendix 1-3: Click "Configure Display Parameters" In the popup dialog click "New Template", then input the horizontal and vertical pixels, click "Save Template" and then "OK" to save the settings.
  • Page 22 EtungTech LED-528 User Manual Figure Appendix 1-4: Create template Figure Appendix 1-5: Set horizontal and vertical pixels Figure Appendix 1-6: Click OK to save settings...
  • Page 23 EtungTech LED-528 User Manual Step 4: Configure Driver In "Terminal Control" select “Set control card driver ". Figure Appendix 1-7: Select "Set control card driver" Ask scan mode from the display vendor. Select correct scan mode in the dialog accordingly.
  • Page 24 EtungTech LED-528 User Manual Figure Appendix 1-9: Check sending status Step 5: Edit Program Under tab "Programs", click "New" to create a new program. Figure Appendix 1-10: Click "New" program Set program size, height and width must match the screen size.
  • Page 25 EtungTech LED-528 User Manual Figure Appendix 1-11: Set program size Add one row of text, set size used on the screen, and font used to display the text, and then click "Save". Figure Appendix 1-12: Set Text size Step 6: Publish Program Click "Publish New"...
  • Page 26 EtungTech LED-528 User Manual Figure Appendix 1-13: Create new publish task Fill in "Task Description", select the program to be published, and click "Next". Figure Appendix 1-14: Add task description Select the terminal to publish the program, click "Next Step", and then click "Confirm Publish"...
  • Page 27 EtungTech LED-528 User Manual Figure Appendix 1-16: Publish the program Step 7: Check if the Program has been Published Check if the program has been sent successfully under tab "Publish Information". Figure Appendix 1-17: Check send status...