Njoy UPAC-TEMPHUM-AZ01B User Manual

Sensor box (temperature & humidity)

Advertisement

Quick Links

Sensor Box (Temperature & Humidity)
UPAC-TEMPHUM-AZ01B
User manual
111.0
Before using this product, carefully read all product documentation and retain it for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UPAC-TEMPHUM-AZ01B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Njoy UPAC-TEMPHUM-AZ01B

  • Page 1 Sensor Box (Temperature & Humidity) UPAC-TEMPHUM-AZ01B User manual 111.0 Before using this product, carefully read all product documentation and retain it for future reference.
  • Page 2 5-4. Connect to power ..................6 5-5. SNMP connection ..................6 5-6. Operation ..................... 7 nJoy UPS models that are compatible with this product: 6. Monitoring software operation ............... 7 6-1. Software installation ................7 Aten Pro Series 1K / 2K / 3K 6-2.
  • Page 3 Function diagram Product overview Humidity Temperature Detection Detection Adapter Optional Communication port Input dry contact terminal Device status indicator +12VDC DC input connector SNMP Manager Contact Product introduction This environmental monitoring device (EMD) is a connectivity device to remote monitor temperature and humidity via SNMP manager. It also provides two dry contacts to receive signals from up to 2 compatible devices Installation such as security system and alarm system.
  • Page 4 5-2. Pre-installation Chart 3 Before making connection to environmental monitor device, make sure the UPS is already installed with SNMP manager. Please check SNMP manager for SNMP card installation. 5-3. Wall-mounting There is a mounting hole on the back of the unit. Simply mount the unit by position the key-hole slot over the mounting screw.
  • Page 5 Step 5:  W henlaunchingViewPowerProsoftware,click“Environmental information”icontoviewstatus. Step 2:  S NMPmanagerwillbeautomatically activated.Select“SNMPmanager”by clickingrightbuttonofthemouse. Step 3:  E nterspecificIPaddresstosearchallSNMPdevicesinLAN. TheSNMPmanagerwillautomaticallycollecttheIPaddress fromseverbydefaultviaaDHCPserver. Troubleshooting Problem Possible Cause Solutions It displays 0 in the SNMP card is not con- Make sure SNMP card is environmental in- nected well. firmly connected in the formation section UPS.
  • Page 6 Specification of environmental monitoring device Model NominalDCinput 12VDC DCinputcurrent 0.5Amin. Temperaturemeasurementrange 0~100°C Temperaturemeasurementaccuracy ±1.5°C Humiditymeasurementrange 10%~90%RH Humiditymeasurementaccuracy ±3% Communication RS232withASCIIprotocol Disposal of Old Electrical & Electronic Equipment Acceptablecablelength 15m Dimension(DxWxH)mm 80×78×28.5 (Applicable in the European Union and other European countries with separate collection systems) Netweight This symbol on the product or on its packaging indicates that this product shall...

Table of Contents