Electrical Connections

IMPORTANT: ENSURE THAT THE ELECTRICITY SUPPLY
IS SWITCHED OFF BEFORE CONNECTING.
Your appliance must be connected to fixed wiring via the
use of a double pole switched fused spur outlet with at
least 3mm contact separation.
(See technical data for fuse rating).
We strongly recommend the appliance is connected by a
qualified electrician who is a member of the N.I.C.E.I.C
who will comply with the I.E.E. and any local regulations.
NOTE
The terminology "DOUBLE POLE" means that both
the live and neutral supplies are switched and
disconnected at the same time.
The terminations labelled SUPPLY are for the connection
for the internal house wiring and the terminations
labelled LOAD are for connection for the appliance.
THIS APPLIANCE MUST BE EARTHED.
IMPORTANT
The wires in this mains lead are coloured in accordance
with the following code:
GREEN / YELLOW
BLUE
BROWN
At the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your spur box,
proceed as follows.
The wire which is coloured green and yellow must be
connected to the terminal which is marked with the letter
E or by the earth symbol
and yellow. The wire which is coloured blue must be
connected to the terminal which is marked with letter N
or coloured black. The wire which is coloured brown
must be connected to the terminal which is marked with
the letter L or coloured red.
- WARNING -
Earth
Neutral
Live
or coloured green or green
BLUE
(NEUTRAL)
GREEN & YELLOW
(EARTH)
TECHNICAL DATA
FUSE RATING:
13AMP
17
BROWN
(LIVE)