Page 1
Operating Manual TFortis SG-Switch Surge protection unit for TFortis PSW switches Version 3...
Page 2
(ESG and PSG) is guaranteed only when they are used as part of TFortis SG-Switches. The specified technical parameters are guaranteed for the protection of TFortis PSW switches manufactured starting 07.2017. Grounding of the switch is obligatory. It is recommended to check the integrity of...
230 VAC supply circuits and Ethernet circuits of TFortis PSW from severe interferences caused by powerful lightning strikes. TFortis SG-Switch increases the level of lightning protection of TFortis PSW switches up to class 5 (according to GOST R 51317.4.5) Figure 1. Typical application scheme Features ...
2. Description Figure 2. TFortis SG-Switch lightning protection device, appearance TFortis PSW have standard built-in lightning protection of 230 VAC power supply circuits and Ethernet (class 2 according to GOST R 51317.4.5, performance criterion B). Since July 2017, all TFortis PSW switches are manufactured with improved lightning protection (class 4 according to GOST R 51317.4.5).
Page 6
Note Classification of technical equipment operating conditions according to GOST R 51317.4.5: Class 0 Protected electromagnetic environment, usually inside a specially equipped room. Class 1 Partially protected electromagnetic environment. Class 2 Electromagnetic environment in case of separation of power cables and signal cables.
Supports IEEE802.3af/at (including 60W) All conductors are protected by the twisted pair Protects Ethernet ports of TFortis PSW switches from powerful pulse interferences – 4 kV, 6.5/700 µs based on the «wire-ground» scheme with performance criterion B (GOST R 51317.4.5) 230V power supply lightning protection module (PSG) ...
WARNING! Drilling of the housing will lead to loss of device integrity and, as a result, loss of product warranty. TFortis SG-Switch can be installed next to the TFortis PSW switch in the same cabinet TFortis CrossBox-2 or CrossBox-3. These cabinets already...
Observe marking of the terminals when connecting the power cable to 230 VAC protection module. Terminal IN – 230 VAC input for connecting the power supply cable. Terminal OUT – 230 VAC output for connecting to TFortis PSW switch. Figure 5. Functions of the connectors of 230 VAC lightning protection module Grounding of the switch is obligatory.
Fig. 6. Connection of the Ethernet cable. When the lightning protection device SG-Switch is located in the same cabinet wit TFortis PSW switch, it is allowed to use a non-shielded twisted pair between these devices. It is recommended to use a 4-pair twisted pair, at least category 5.
6. Supply scope Name Note TFortis SG-Switch lightning protection device Components: Ethernet module (ESG) – 5. 230 V module (PSG) – 1. Cable gland 4-8 mm (PG9) Product certificate 7. Manufacturer's warranty The warranty period for the switch is 36 months from the date of sale. Only a complete switch is accepted for servicing and repair.