Summary of Contents for Power Breezer Mach 4+

  • Page 1 Troubleshoo ng Guide for Power Breezer Mach 4+ SCOPE This guide provides instruc ons for troubleshoo ng for the Power Breezer Mach 4+ REVISION HISTORY Rev. No. Date Author Comment 07.22.2021 George Douglas Original Document...
  • Page 2 Warnings: ● Any repairs on a Power Breezer® should be made only by authorized personnel or Power Breezer personnel. Any repairs/modifica ons by others will void the unit’s warranty. ● Breezer has made every effort to ensure that the direc ons provided in this Troubleshoo ng Guide are complete and accurate.
  • Page 3 ● Children can fall into an open water reservoir and drown, even in a small amount of water. ● Keep children away from the reservoir. Keep the reservoir lid on at all mes. ● Closely supervise all nearby children and pets when using this Cooling Unit. Do not leave the Cooling Unit una ended.
  • Page 4: Table Of Contents

    Table of Contents Tools and Materials Needed Verification No Power Fan Not Working Atomizer Not Misting Atomizer Not Spinning Head Is Not Rotating Water Pump Not Working Properly Appendix: A. How to Access and Remove the E-Box B. How to Substitute a Control Panel...
  • Page 5: Tools And Materials Needed

    Tools and Materials Needed Tools: ● Complete Socket Set ● Phillip’s Head Screwdriver ● Flat Head Screwdriver ● “Punch-Down” Tool ● Wire cu ers ● Wire Strippers ● Universal Crimpers ● Allen wrench set ● Digital VoltMeter (“Meter”) Parts: (tested as func onal) ●...
  • Page 6: No Power

    Step 1 Power Source Inspect the power cord and its connec on to the power source. Power Breezer fans can draw as much as 15 to 20 Amps on startup at Full Power. Check the power source’s circuit breaker. Verify the power source with a Digital Volt Meter. Set your meter for MODE: A/C voltage , RANGE: 300 or higher.
  • Page 7: Fan Not Working

    Fan Not Working Make sure to unplug the unit while checking connec ons or anything pertaining to the electronic box and plug back in when tes ng. Possible Causes of Fan Failure: 1. Obstruc on 2. Damaged Cable /Incomplete Connec ons in the E-Box 3.
  • Page 8 c. If the relay has + 12 on posi on 0 and -12 on posi on 1 and no audible “click” is heard when the power bu on (Red) is pressed on the Control Panel, change the relay and test. If the “Click”...
  • Page 9: Atomizer Not Misting

    4. Atomizer Troubleshoo ng Step 1 Water Pump Unplug the Power Breezer for 30 seconds then begin to troubleshoot the pump. Ensure there is sufficient water to cover the intake of the pump. All hoses are connected correctly. Pick up the pump and feel for vibra on - ensuring power is ge ng to the pump.
  • Page 10 Remove the 3 screws from the Atomizer Plate Cover. Remove the 3 screws from the Atomizer Plate. The center of the plate is now visible, on the sha are the (2) set screws; make sure they are not loose. The plate can now be removed from the sha exposing the pipe. Ensure the pipe is clear of any debris.
  • Page 11: Atomizer Not Spinning

    Atomizer Not Spinning Make sure to unplug the unit while checking connec ons or anything pertaining to the electronic box and plug back in when tes ng. Possible Causes of Atomizer Failure: 1. Control Panel 2. Wiring of the E-Box 3.
  • Page 12: Head Is Not Rotating

    Head Is Not Rota ng Make sure to unplug the unit while checking connec ons or anything pertaining to the electronic box and plug back in when tes ng. Possible Causes of Rota on Failure: 1. Obstruc on 2. Control Panel 3.
  • Page 13 Step 4 Rota on Motor Assembly To access the Rota on Motor: a. The head must be placed on the side or back into the tank. b. The hex screw, on the bo om of the rota on pipe, must be removed. c.
  • Page 14: Water Pump Not Working Properly

    Water Pump Not Working Properly Make sure to unplug the unit while checking connec ons or anything pertaining to the electronic box and plug back in when tes ng. Possible Causes of Pump Failure: 1. Water Hose 2. Wiring of the E-Box 3.
  • Page 15 Step 3 Control Panel Verify the wiring of the Control Panel. Subs tute the Control Panel with a known good Control Panel and test. If the water Pump func on is working with the subs tuted Control Panel then replace the Control Panel and test.
  • Page 16: Appendix

    Appendix: A. How to Access and Remove the E-Box Make sure to unplug the unit before checking connec ons or anything pertaining to the electronic box (E-Box). A. Look at drawing 140-000-000 and locate where the E- Box is situated with respect to the Breezer.
  • Page 17: How To Substitute A Control Panel

    B. How to Subs tute a Control Panel Make sure to unplug the unit while checking connec ons or anything pertaining to the electronic box. A. Have a known good Control Panel with its Control Cable (6 wires in the Control Cable are black and numbered 1 through 6 and a green wire is referenced as 7).
  • Page 18 4. Remove the water pump wires from the E-Box. D. Locate the Control Panel on the Power Breezer and li the tray that the Control Panel is seated in; this will expose the DC Pump Cable going from the E-Box to the tank. Pull the DC Pump Cable up from the E-Box.