  • Page 1 RLY-6 RELAY INTERFACE INSTRUCTION MANUAL...
  • Page 2 Room 1806, Hua Bin Building No. 8 Yong An Dong Li Jian Guo Men Wai Ave Chao Yang District Beijing, P.R. China 100022 ® Clear-Com, CellCom/FreeSpeak and the Clear-Com Communication Systems logo are registered trademarks of The Vitec Group plc.
  • Page 3: Table Of Contents

    Liability ..........W-iii Vitec Group Communications RLY-6 Interface Instruction Manual...
  • Page 4 Vitec Group Communications RLY-6 Interface Instruction Manual...
  • Page 5 When you see these symbols on this product, they warn you of the potential danger of electric shock if the station is used improperly. They also refer you to important operating and maintenance instructions in the manual. Vitec Group Communications RLY-6 Interface Instruction Manual...
  • Page 6 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Vitec Group Communications RLY-6 Interface Instruction Manual...
  • Page 7: Operation

    RJ-45 accessory data connector on the matrix frame. independent, single-pole, double-throw (SPDT) relays The Eclipse system supports up to 10 RLY-6 interfaces, for a total of 60 that are directly controlled by outputs. You can use a mix of GPI-6 and RLY-6 interfaces to support the matrix.
  • Page 8: Operation

    Logical control of the relays in the RLY-6 interface is provided by associating a relay with any other label in the system using the Eclipse Configuration System programming software. Activating a TALK or LISTEN label with a relay associated to it will also activate that relay.
  • Page 9: Installation

    TO MATRIX To connect the RLY-6 to the matrix, plug one end of a RJ-45 cable (eight wires with no reversal) into the GPI-RLY INTERFACE connector on the back of the matrix. Plug the other end into the top RJ-45 (CH. A MATRIX) connector for the RLY-6.
  • Page 10: To External Device

    1 to 6 for RLY 2, etc. RLY interface 0 is the internal Matrix RLY interface. For Eclipse systems if both GPI-6 and RLY-6 interfaces are used the GPI-6 interfaces are required to be placed first in the daisy chain. This restriction does not apply to Matrix Plus 3 systems where interfaces can be mixed in this 'daisy-chained' scheme.
  • Page 11 #1/4 Normally Closed #1/4 COM #1/4 Normally Open #2/5 Normally Closed #2/5 COM #2/5 Normally Open #3/6 Normally Closed #3/6 COM #3/6 Normally Open Figure 2-2: RLY-6 Interface DB-9M Connector Pinout Vitec Group Communications 2 - 3 RLY-6 Interface Instruction Manual...
  • Page 12: Configuration

    CONFIGURATION To associate a relay to a label, use the Eclipse Configuration System (ECS) programming software, as described in its manual. 2 - 4 Vitec Group Communications RLY-6 Interface Instruction Manual...
  • Page 13: Specifications

    Performance specifications included in this manual are design-center specifications and are included for customer guidance and to facilitate system installation. Actual operating performance may vary. Vitec Group Communications 3 - 1 RLY-6 Interface Instruction Manual...
  • Page 14 3 - 2 Vitec Group Communications RLY-6 Interface Instruction Manual...
  • Page 15: Limited Warranty

    • UHF wireless intercom systems have a limited warranty of three years. • All other Clear-Com and Drake brand systems and products, including beltpacks, have a limited warranty of two years. The warranty starts at the time of the product’s original purchase. The...
  • Page 16: Warranty Repairs And Returns

    Telephone for Europe, Middle East and Africa: +49 40 6688 4040 or +44 1223 815000 Telephone for the Americas and Asia: +1 510 337 6600 Email: vitec.support@AVC.de Once the standard warranty period has expired, the User Support Center will continue to provide telephone support if you have purchased an Extended Warranty.
  • Page 17: Extended Warranty

    EXTENDED WARRANTY You can purchase an extended warranty at the time of purchase or at any time during the first two years of ownership of the product. The purchase of an extended warranty extends to five years the warranty of any product offered with a standard two-year warranty. The total warranty period will not extend beyond five years.