Page 1
Dehumidifiers X-125 X-150 X-200 Read this manual carefully before use and keep it for future reference. Failure to do so may result in injury, property damage and may void the warranty. avalla.com...
Contents Contents Quick start guide: X-125 and X-150 • Parts guide • Touch control panel Quick start guide: X-200 • Parts guide • Touch control panel General operating instructions • Empty water tank • Continuous drainage • Cleaning the air filter Troubleshooting •...
Quick start guide: X-125 and X-150 Parts guide 01. Air outlet 05. Drainage outlet 02. Air humidity indicator 06. Water tank 03. Touch control panel 07. Drainage hose 04. Air inlet Touch control panel...
Page 4
Power: Press to toggle power on/off. Mode: Press to cycle between operation modes: • Dehumidifier: The unit will stop operation when it has reached target humidity level and will automatically resume if humidity rises again. • Continuous dehumidifier: The unit operates unrestricted by target humidity levels.
Quick start guide: X-200 Parts guide 01. Touch control panel 05. Drainage outlet 02. Air humidity indicator 06. Water tank 03. Air outlet 07. Drainage hose 04. Air inlet Touch control panel...
Page 6
Power: Press to toggle power on/off. • Power indicator illuminates when on and flashes when in standby mode. Mode: Press to cycle between operation modes: • Dehumidifier: The unit will stop operation when it has reached target humidity level and will automatically resume if humidity rises again.
03. Return the water tank and continue operation. X-125 and X-150 X-200 Continuous drainage The unit can operate for prolonged periods, bypassing the water tank. Note: the water tank must be installed or the machine will not run.
Troubleshooting Issue Cause Solution Wait for the Automatic Unit switches off defrosting mode to defrosting end. If room is below 18ºC the unit will Defrosting mode Room temperature require more happens frequently too low frequent defrosting to maintain correct operation. Make sure the room size matches the operational...
Health and safety General safety instructions Symbols from the unit This unit uses Class I Read the user manual Service personnel are a flammable Construction carefully before required to carefully refrigerant. (Earthed) operation. read the user manual. If the refrigerant leaks and encounters fire or heat, it may create harmful gas and there...
Page 10
• Always operate the unit from a grounded power outlet of equal voltage, • frequency and rating as indicated on the product identification plate. Do not operate with wet hands. Keep the unit away from sources or water, • moisture, or any other liquids. Do not leave the unit running unattended.
Page 11
must use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space.
Failure to abide by any of these warnings could result in a fire, explosion, electric shock, injury, death, and property damage. Avalla Ltd. Unit A 73, Common Road, Chandler’s Ford, Eastleigh, SO53 1HE. United Kingdom Company no. 13477899...