    PTY LTD COMPACT 10/120 USER MANUAL Thank you for purchasing a quality Pumps Australia Unit. We reserve the right to make changes at any time without incurring any obligation. Owner/User Responsibility: The owner and/or user must have an understanding of the manufacturer’s operating instructions and warnings before using this Stand Alone Boiler.
  • Page 3 17. Manufacturer will not be liable for any changes made to our standard machines or any components not purchased from Pumps Australia Pty Ltd. 18. The best insurance against an accident is precaution and knowledge of the machine.
  • Page 4: Machine Identification

    Absorbed Power Voltage V – Hz 230-50 400-50 400-50 Max. Flow L/min. Temperature  30°-120° 30°-120° 30°-120° Fuel Tank Detergent Tank Weight MACHINES DIMENSIONS PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 5: Main Parts

    10 FUEL FILTER 11 HIGH-PRESSURE PUMP 12 PRESSURE VALVE 13 COMBUSTION HEAD 14 PRESSURE SWITCH 15 PRESSURE GAUGE 16 FULE PUMP 17 BURNER MOTOR PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 6: Safety Norms

    Always check the isolation of the electric cable as well as the equipment’s integrity. PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 7: Machine Installation

    60°C. Picture 5 Fill the fuel tank F (See picture 6) with Diesel. Fill the detergent tank G (See picture 6) with a Detergent PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 8 Make sure that the electrical tension and amperage are suitable for the machine. The cleaner must be connected to a suitable feeding point equipped with an efficient contact to earth and controlled by an overload cut out switch. PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106...
  • Page 9: Machine Startup

    The hydraulic system is equipped with a safety valve that works whenever the pressures are higher than the calibration. PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 10: Standard Equipment

    10 mt high-pressure hose, and a nozzle suitable for the model you have purchased. OPTIONS ”PUMPS AUSTRALIA” supplies a rotary jet nozzle on request which allows you to remove the hardest dirt from any surfaces you want to clean and wash. DETERGENTS It is recommended to use only liquid detergents to avoid using powder detergents.
  • Page 11: Electrical Diagram

    DESCRIPTION DESCRIPTION Pump motor Contactor Electrovalve Electronic card High tension transformer for electrodes 15 bar Pressure switch Burner Motor 40 bar Pressure switch Thermostat PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 12 DESCRIPTION DESCRIPTION Pump Motor Contactor Electrovalve Electrical Card High tension transformer for electrodes 15 bar Pressure Switch Burner Motor 40 bar Pressure Switch Thermostat PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 13: Hydraulic Diagram

    21 – Fan 9 – Pressure Switch 22 – Safety Valve 10 – Pump 11 – Electrical Motor 12 – Detergent Ejector 13 – Detergent Filter PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 14 Make sure that the stickers/labels are present on the machine and that they are readable; if they are missing or erased, please attach or replace them. Ask for them from the licensed dealers. PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106...
  • Page 15: Maintenance

    For further information, please contact your local committee for exhaust oil drainage. PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106...
  • Page 16 DIESEL FUEL PUMP FUEL PUMP ADAPTOR 240VAC BURNER MOTOR 12VDC BURNER MOTOR FAN BLADE (LEFT ROTATION) FAN BLADE (RIGHT ROTATION) 240VAC IGNITION TRASFORMER 12VDC IGNITION TRANSFORMER PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 17 Fan System Solenoid & Fuel Pump System Transfomer Inner Coil Assembly Boiler Pad Fuel System Electrical System Please Note: 240VAC Option Shown, 12VDC will vary. PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 18: Parts Breakdown

    44 45 47 48 UN003304-MR KIT RICAMBI / PART KITS UN003305-AS sp_00500_RK_N PUMPS AUSTRALIA PTY LTD PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 19 Tenute acqua/Water seals ø 22 Olio - Oil Tipo / Type Quantità / Quantity SAE 15W40 0,435 Kg MI 91423 DI_1388523 (3056) (2322) (2990) PUMPS AUSTRALIA PTY LTD PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 20 PRESSING THE ON/OFF switch SWITCH SUDDEN MOTOR The thermal protection is not working Make sure that the STOP due to overheating tension is suitable PUMPS AUSTRALIA PTY LTD PHONE: 1800 790 915 212 Welshpool Road, Welshpool WA 6106 EMAIL: Sales@Pumpsaustralia.com.au...
  • Page 21: Warranty Conditions

    PUMPS AUSTRALIA cannot be responsible for any improper use, for parts subject to wear, for the electrical parts, for the labour, for the delivery costs of the components under warranty.
  • Page 22 AUSTRALIAN OWNED & OPERATED Established in 1997 as a backyard business, Pumps Australia has had steady growth over 20 years by supplying quality products with quality service using quality people. Being a firm believer of always having what you need in stock, our large warehouse locat- ed in Welshpool carries a HUGE inventory of stock for our customers.