User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XK3101 and is the answer not in the manual?

Questions and answers

Summary of Contents for Oakley XK3101

  • Page 1 XK3101(HL-2065) Indicator User’s Manual...
  • Page 2: Table Of Contents

    Contents Main Data………………………………………………………………………1 2. Main Functions ……………………………………………………………… 1 3. Construction … ……………………………………………………………… 2 4. Installation Connection………………………………………………………4 Operation Keys Instruction…………………… ……………………………4 Use Instruction ……………………………………………………………… 5 6.1 Turn-on Operation ……………………… ………………………………… 5 6.2 Turn-off Operation …………………………………………………………5 6.3 Zeroing …………………………………………………………………………5 6.4 Deducting Tare …… …………………………………………………………5 6.5 Conversion between “kg”...
  • Page 3: Main Data

    6.8 Bill-printing output……………………………………………………………7 6.9 Digit Input………………………………………………………………………8 7. Use Guide ………… ………………………………………………………… 8 8. Calibration …………………………………………………………………… 9 9. Simple Rectifying……………………………………………………………12 10. Information Prompt …………………………………………………………13 1. Main Data Zero-load signal input range: 0 ~10mV Zero temperature-drift: ≤0.15μv/℃ Sensitivity temperature-drift: ≤12 ppm/℃ A/D conversion resolution ration: 300000 Display resolution ration:...
  • Page 4: Main Functions

    Power supply: AC110V/220V/230V/240V, 60/50Hz Note: For the actual value, see the nameplate on the indicator. 1.18 Installation style:Tower mode or table mode or wall mode 1.19 Dimension (L×H×W): XK3101(HL-2065B) 248×125×162mm XK3101(HL-2065C) 162×125×167mm 1.20 Dead weight (kg): XK3101(HL-2065B) ≤ 2.6kg XK3101(HL-2065C) ≤ 1.5kg 2.
  • Page 5 Figure 1: XK3101 (HL-2065B Figure 2: XK3101 (HL-2065C) 3.2 Panel...
  • Page 6 Figure 3: Panel ① 6-digit LED ② “ZERO” indicating light ③ “STAB” indicating light ④ “AC” indicating light ⑤ “NET” indicating light ⑥ “lb” indicating light ⑦ “kg” indicating light [MODE]/[→] key [TARE]/[ENTER] key [ZERO]/[↑] key [PRINT]/[ON]/[OFF] key 3.3 Cursors and their meanings There are 6 LED indicating-cursors on this indicator, for the names and meanings, see the following table: Cursor symbol...
  • Page 7: Installation Connection

    “NET” Appears when the display value is net “lb” Appears when the weight unit selected is “pound” “kg” Appears when the weight unit selected is “kilogram” 4. Installation connection If power adapter input, for its pole, see Figure 4a. Figure 4a: Power adapter input Load cell input 4.2.1 If the 5-core aerial outlet is used for the load cell connecting, see Figure 4b.
  • Page 8: Operation Keys Instruction

    5. Operation Keys Instruction [ZERO]/[↑] key a. Under weighing state, you can use this key to make the display return to zero. b. Used for increasing the value of the selected figure. c. Under weighing state, keep pressing this key for 3 seconds, the indicator will automatically convert the weight unit between “kg”...
  • Page 9: Zeroing

    Zeroing When the weight value displayed by the indicator is less than 2%F•S, press [ZERO] to make the display return “0” and at the same time the “ZERO” cursor appears. While carrying through repeat zero, you can make the display of not more than 5%F•S return zero. When the “NET” indicating cursor is on,can’t carry through zeroing operation.
  • Page 10: Rs-232 Output

    awaiting the stabilization cursor“STAB” appear, press [TARE] to confirm. Note: You should place the samples with verified amount on the scale platform almost at the same time. And the weight of single sample should approach the display division value as far as possible. 6.6.2 Counting After finishing the sampling-operation, you can load the even-weight article like sample on the scale platform, at this time the indicator displays the article amount on the scale platform.
  • Page 11 1-digit decimal 2-digit decimal 0.00 3-digit decimal 0.000 4-digit decimal 0.0000 State B: comprehensive control character Verification bit Dynamic mark bit D3=0, stability; D3=1, non-stability (dynamic) Overload mark bit D2=0, normality; D2=1, overload Positive and negative mark bit D1=0, positive number; D1=1, negative number Gross weight and net weight mark bit D0=0, gross weight;...
  • Page 12 Figure 7: Bill mode 6.8.2 Connection between the indicator and the printer Connect an end of printer cable to the D-shape 25-core joint (pin) for the printer and the other end to 5-core metal outlet for the indicator. See the following drawing. Figure 8: Connection between the indicator and the printer 6.8.3 Printing pattern Instruction A.
  • Page 13 Step 7: Press [TARE] to confirm. Thus the input operation for a group of digit is completed. Use Guide Be sure that the ground terminal of AC power is properly grounded. Weighing (tare included) can’t exceed Max. Capacity plus 9e (“e” refers to graduation). If exceed, the indicator displays “OVER”.
  • Page 14 indicator enters setting / calibrating state. b. Need to open the indicator front-cover. For entering setup/calibration, open its front cover, find out the short circuiter W1 and join 2 and 3 pin short. At this time the indicator automatically enter setup/calibration mode and displays “CAL 0” after “SET UP”...
  • Page 15 [CAP 3] refers to full range selecting: The indicator displays full range data to be selected after it displays “CAP” data for about 2 seconds. At this time you can press [→] to select the full range value, and then press [ENTER] to confirm.
  • Page 16 600 ㎏ 0.02kg; 0.05 ㎏; 0.1 ㎏; 0.2 ㎏; 300 ㎏ 1000 ㎏ 0.1 ㎏; 0.2 ㎏; 0.5 ㎏; 1 ㎏ 500 ㎏ 2000 ㎏ 0.1kg; 0.2 ㎏; 0.5 ㎏; 1 ㎏; 1000 ㎏ 3000 ㎏ 0.1kg; 0.2 ㎏; 0.5 ㎏; 1 ㎏;...
  • Page 17 then press [ENTER] to confirm, at this time the indicator displays “PASS”(the indicator is reading the range datum of the scale ). After several seconds, the indicator automatically turns to the ambient data group, thus the range calibrating is finished. Step 4: ambient data group [F1 X] refers to power-on auto-zero range.
  • Page 18 [F4 X] refers to dynamic testing-time. X=0.5 / 1.0 / 2.0 / 3.0 (s). The time for scale from dynamic to stabilization depends on the dynamic testing-time. If you need to change the above data, press [→] to select and then press [ENTER] to confirm. If don’t, directly press [ENTER], at this time the indicator enters F5 setup.
  • Page 19 [F7 X] refers to the Baud rate to be selected, with 5 options. X=1 relevantly 600. X=2 relevantly 1200. X=3 relevantly 2400. X=4 relevantly 4800. X=1 relevantly 9600. [F8 X] refers to extension display mode. X=0 / 1. X=0 refers to no extension display. X=1 allow to extension display.
  • Page 20 9. Simple Rectifying Under normal weighing and zero-load state, keep pressing [MODE] for 3 seconds, the indicator displays“ ‘0’00000” (the flashing‘0’is the selected digit, if don’t need to rectify, press [ENTER] to withdraw). Load the rectification weights on the scale platform and input the weight value for the indicator.