AIPDB1215WA81/01 TFT panel for rolling stock Operation manual Version 1.01 aipdb1215wa8101_g_en_101...
Page 2
AIPDB1215WA81/01 AMiT, spol. s r. o. does not provide any warranty concerning the contents of this publication and reserves the right to change the documentation without obligation to inform anyone or any authority about it. This document can be copied and redistributed under following conditions: 1.
AIPDB1215WA81/01 History of revisions Document name: aipdb1215wa8101_g_en_101.pdf Author: Ondřej Rott Revision Date Changes 7. 4. 2015 New document 1. 9. 2015 Changes in chapters 2. Technical parameters, 2.4. Recommended drawing symbol, 4. Power supply, 5. Digital inputs / outputs and 6. Communication lines and peripherals.
AIPDB1215WA81/01 1. Introduction AIPDB1215WA81/01 is a TFT panel for rolling stock. 2 × 21.5“ TFT display, resolution 1920 × 1080, LED backlight Basic features CPU MSC Q7-BT-15-2201I Linux operating system 2 × USB 1 × RS422 ...
AIPDB1215WA81/01 2. Technical parameters CPU module Module MSC Q7-BT-15-2201I Processor Intel Atom E3815 Single-Core 1.46 GHz, 5 W TDP SDRAM 2 GB DDR3L FLASH memory 4 GB eMMC Flash 2 × TFT, 21.5“ Display Type (1920 × 1080) pixels Resolution Number of faulty pixels Max.
Page 7
AIPDB1215WA81/01 Log. 0 output voltage Log. 1 output voltage Power supply voltage Maximum output current 0.5 A Galvanic separation Yes, 500 V AC / 1 minute *) Connection point WAGO 769-106/021-000 Wire cross section 0.75 mm to 1.5 mm Note *) Insulation must not be used for dangerous voltage separation.
Page 8
AIPDB1215WA81/01 Dimensions (w × h × d) (554 × 360 × 326) mm Package dimensions (w × h × d) (580 × 380 × 350) mm Dangerous Unit overall mass of plastics 1783 g materials Included mass of self-extinguishing 1783 g...
Mounting holes are intended to be used with 4 M8 screws. 4 x O 9 415,0 Fig. 3 - Location and dimensions of AIPDB1215WA81/01 mounting holes 2.4. Recommended drawing symbol Following drawing symbol is recommended for AIPDB1215WA81/01 TFT...
AIPDB1215WA81/01 2.5. Type label Type label is located inside units mechanics. Included data are summarized in the table: Description Data Note – Logo AMiT Producer logo – QR code Product QR code TYPE AIPDB1215WA81/01 Unit type designation xxxxxxx Serial number POWER 24 V DC / 2.10 A...
Page 12
AIPDB1215WA81/01 Fig. 6 - Location of type label (illustrative picture) aipdb1215wa8101_g_en_101 12/37...
AIPDB1215WA81/01 3. Conformity assessment The equipment meets the claims of Czech government decree NV616/2006; the compliance assessment has been performed in accordance with harmonized standard EN 50121-3-2:2006 in obligatory scope given by EN 50155:2007. Tested in accordance Type of test...
AIPDB1215WA81/01 3.1. Other tests This product was assessed and approved for use in railway applications according to standards: Tested in accordance Type of test Classification with standard Railway applications – Electronic EN 50155:2007 Complies equipment used on rolling stock Railway applications – Electromagnetic...
TFT panel is installed. Connector location AUDIO + RS422 Fig. 7 - Location of AIPDB1215WA81/01 power supply connector Legend Number Meaning Connector X1 – Power supply 4.1. Turning TFT panel on and off TFT panel is turned on after connection of power supply to Vcc and GND terminals and activation by SB signal.
AIPDB1215WA81/01 4.1.1 SB input is used Power ON In terms of data consistence, the unit's start-up is not critical and can be realized either by coincident connecting of power supply voltage to Vcc and SB terminals, or by connecting the voltage first to Vcc terminal and then to SB, or vice versa.
AIPDB1215WA81/01 Incorrect shut down process is when the application doesn’t turn off during toff2. toff2 Fig. 9 - Incorrect start up and shut down 4.1.2 SB input is not used Power ON In terms of data consistence, the unit's start-up is not critical and can be...
Pins can be used as an inputs or outputs with backward reading, bun never as input and output simultaneously. Connector location AUDIO + RS422 Fig. 10 - Location of AIPDB1215WA81/01 power supply connector Legend Number Meaning Connector X1 – Power supply...
Page 19
AIPDB1215WA81/01 Inputs Maximum input level for log. 0 4.5 V Minimum input level for log. 1 12.5 V For proper input functionality output must be set to value log. 0. Outputs Log. 1 output voltage Log. 0 output voltage Setting the output to log. 1, will connect power supply voltage to DIOx terminal.
6. Communication lines and peripherals 6.1. RS422 TFT panel AIPDB1215WA81/01 contains one RS422 interface led out on the X4 connector. X4 connector is common for RS422 and Audio. The line is not galvanically separated, i.e. it is galvanically connected with chassis.
AIPDB1215WA81/01 6.2. Audio TFT panel AIPDB1215WA81/01 contains Stereo Audio output. For audio output is used the Cirrus Logic codec CS4207 which meets the HDA standard. Audio output is led out on the connector X4. X4 connector is common for RS422 and Audio.
AIPDB1215WA81/01 6.3. Ethernet TFT panel AIPDB1215WA81/01 is fitted with 4-pin connector M12 for connection to Ethernet network. When using this type connector, data communication rate is limited to 10 / 100 Mbps. AUDIO + RS422 Fig. 14 - Ethernet connector location Legend...
AIPDB1215WA81/01 6.4. USB This is a standard PC interface. TFT panel AIPDB1215WA81/01 has 2 USB ports built-in, with A-type connectors according to USB 2.0 standard. Connectors are located on the rear side of TFT panel mechanics. AUDIO + RS422 Fig. 16 - Location of USB connectors...
AIPDB1215WA81/01 6.5. Indication LED TFT panel contains four indication LEDs. LEDs are used for indication of TFT panel current status. LED label / State indicated Indication colour SYS / green TFT panel is ON and its internal temperature is in...
AIPDB1215WA81/01 7. Mounting TFT panel is intended to be mounted on the vehicle ceiling by means of mounting console, which is a component of the unit. Mounting procedure is described in detail in chapter 7.1. Location of mounting holes is described in chapter 2.3.
Page 26
AIPDB1215WA81/01 2 x M4 4 x M4 Fig. 18 - Location of M4 screws on the unit’s cover Internal part of TFT panel is connected to the cover with yellow-green PE protective conductor. Disconnect faston connector on the yellow-green PE protective conductor.
AIPDB1215WA81/01 7.1.3 Unfolding the display Loosen 4 M6 screws, as shown on figure below. It is necessary to loosen the screws only on the side with electronics and connectors! Do not remove M6 screws completely, just loosen them! Unfold the panel side with the display and connectors.
AIPDB1215WA81/01 Fig. 22 - Unfolding the TFT panel side with electronics 7.1.4 Mounting on the ceiling Mounting to the ceiling of the vehicle is performed by means of 4 M8 screws Mount TFT panel to the ceiling of the vehicle. Location of mounting holes is described in chapter 2.3.
AIPDB1215WA81/01 Cables are connected to the unfolded side of the display. Fig. 24 - Connector location 7.1.6 Folding the display back Fold back the display side containing electronics and connected cablings. When folding the side back – hook M6 screws, located on the display upper side, into the grooves on the supporting console.
AIPDB1215WA81/01 4 x M6 Fig. 26 - Location of 4 M6 screws on the side of the TFT display 4 x M6 Fig. 27 - Location of 4 M6 screws on the side of the TFT display – side view 7.1.7...
Page 31
AIPDB1215WA81/01 Fig. 28 - Location of the faston on the unit’s cover Fig. 29 - Putting the outer cover on the TFT panel 31/37 aipdb1215wa8101_g_en_101...
AIPDB1215WA81/01 2 x M4 4 x M4 Fig. 30 - Location of M4 screws on the unit’s cover 7.2. Mounting claims PE terminal of power supply connector must be connected with local installation earthing terminal. Power supply conductors cross-section must be at least 0.75 mm Ethernet connection cables must be shielded.
AIPDB1215WA81/01 8. Ordering information and completion Information AIPDB1215WA81/01 Complete, see chapter Completion panel 8.1. Completion AIPDB1215WA81/01 Part Quantity TFT panel for rolling stock X1 connector counterpart WAGO 769-104/021-000 Routine testing protocol Insulation testing protocol Certificate of product quality and completeness 8.2.
AIPDB1215WA81/01 9. Packing Unit is packed in bubble wrap and placed into paper box. Package dimensions are listed in chapter Technical parameters. Label Sticker on the box contains following information: Item Description TYPE AIPDB1215WA81/01 NETTO 17.70 kg BRUTTO 19.20 kg...
AIPDB1215WA81/01 10. Storing To prevent damage of the device, follow these rules. Device in Device in original packaging must be stored under the conditions specified in a package chapter Technical parameters. Device must not come into contact with water, oil or any other liquids, that can damage the packaging.
AIPDB1215WA81/01 11. Maintenance Warning With exception of cleaning the device requires no periodic control nor maintenance. Cleaning Depending on equipment usage, the dust is to be removed occasionally from equipment. The display surface can be cleaned by dry or slightly moisten cloth.
AIPDB1215WA81/01 12. Waste disposal Electronics The disposal of electronic equipment is subject to the regulations on handling disposal electrical waste. The equipment must not be disposed of in common public waste. It must be delivered to places specified for that purpose and recycled.