Summary of Contents for Kane INF165C

  • Page 1 INF165C ® 12:1 Infrared Thermometer INSTRUCTION MANUAL ENGLISH ® CLASS llla LASER PRODUCT LASER RADIATION WHEN OPEN LASER RADIATION - AVOID DIRECT EYE EXPOSURE COMPLIES WITH FDA 21 CFR SUBCHAPTER J 1.800.561.8187 information@itm.com www. .com...
  • Page 2: Table Of Contents

    TABLE OF CONTENT Important Safetey Warnings Symbol Functions Features Overview Operating Instructions Specifications Storage Warranty Disposal Cleaning 1.800.561.8187 information@itm.com www. .com...
  • Page 3: Important Safetey Warnings

    IMPORTANT SAFETEY WARNINGS WARNING Read entire Safety Notes section regarding potential hazard and proper instructions before using this tester. In this manual the word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to indicate conditions or actions that may damage this instrument.
  • Page 4: Symbol

    SYMBOLS Low battery Degrees fahrenheit Degrees Celsius FUNCTIONS • Temperature range: -76˚ to 1022˚F (-60° to 550°C) • 12:1 Distance-to-spot ratio FEATURES • Circular laser targeting • Max value capture • Emissivity: Fixed 0.95 • Auto power off 1.800.561.8187 information@itm.com www.
  • Page 5: Overview

    OVERVIEW LOCK LOCK CLASS llla LASER PRODUCT CLASS llla LASER PRODUCT LASER RADIATION WHEN OPEN LASER RADIATION WHEN OPEN LASER RADIATION - AVOID LASER RADIATION - AVOID DIRECT EYE EXPOSURE DIRECT EYE EXPOSURE COMPLIES WITH FDA 21 CFR COMPLIES WITH FDA 21 CFR SUBCHAPTER J SUBCHAPTER J Mode...
  • Page 6: Operating Instructions

    OPERATING INSTRUCTIONS ERROR MESSAGES The thermometer incorporates visual diagnostics messages as below: ER2: is displayed when the thermometer is exposed to rapid changes in ambient temperatures. ER3: is displayed when the ambient temperature exceeds 32˚F (0˚C) or 122˚F (50˚C).The tester should be allowed plenty of time to stabilize in the working temperature.
  • Page 7: Specifications

    SPECIFICATIONS Temperature Range -76˚ to 1022˚F (-60˚ to 550˚C) Operating Temperature 32˚ to 122˚F (0˚ to 50˚C) Accuracy ± 2.7˚F (1.5˚C) (Tobj=15-35˚C, Tamb=25˚C) Accuracy Tobj=0~550˚C: ±2% of reading or (Tamb=23 ± 3˚C) 2˚C(4˚F) whichever is greater Tobj=-60~0˚C: ±(2˚C+0.05/degree C) Emissivity Fixed 0.95 Resolution (-9.9˚...
  • Page 8: Warranty

    Kane shall not be liable for loss of use of the instrument or other incidental or consequential damages, expens- es, or economic loss, or for any claim or claims for such damage, expenses or economic loss.