Summary of Contents for SM PURBROOK
Page 1
AND MAINTENANCE INSTRUCTIONS This document details the correct procedure for installing and maintaining the following locking systems: • Purbrook single point emergency exit devices suitable for use on single leaf doorsets (compliant with BS EN 179) o PB105 o PB115 o PB125 •...
Page 2
PURBROOK INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS THESE INSTRUCTIONS CONTAIN IMPORTANT SAFETY AND MAINTENANCE INFORMATION AND MUST BE PASSED TO THE END USER. The safety features of this product are essential to its compliance with EN179. The suppled keeps should be used to ensure compliance.
Page 3
PURBROOK INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 1. Ensure the door leaf is hung correctly and opens freely. Position the template accurately on door as indicated below. Note; this allows for 6mm (1/4”) gap between the edge of the lock and the strike for the standard keep plate or 10 mm (3/8”) for roller keeps. The gap may be...
Page 4
PURBROOK INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 2. Drill holes in door to suit chosen fixing method. For timber doors, core fixings are recommended for maximum security and fire performance. For metal doors, machine screws going into an 8mm (5/16”) tapping plate within the leaf are recommended for maximum security and fire performance.
Page 5
PURBROOK INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 6. If using the Purbrook Anti-Drill mount plate, assemble as shown below, ensuring the textured side of the anti-drill insert is to the attack side. Anti-drill mount plate Ensure textured side on the insert is to the attack side...
Page 6
PURBROOK INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 10. Maintenance instructions It is recommended that the following routine maintenance checks be undertaken at monthly intervals: • Inspect and operate the lock to ensure that all components are in a satisfactory working condition and the release forces are within those detailed above.
Page 7
PURBROOK INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 11. Operating instructions 1 Entry a. Release the deadlock (if applicable) using the key or electric release (as applicable, see product codes) b. Whilst the deadlock is being held in the released position, fully depress the handle to retract the boltwork.
Page 8
PURBROOK INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 13. Wiring diagrams Maximum voltage through monitoring switches = 50V Maximum current through monitoring switches = 500mA Maximum solenoid voltage/current: 12V systems = 14V max, use 2.5A fuse 24V systems = 28V max, use 2.5A fuse...