  • Page 1 INSTALLATION GUIDE Corridor Lamp 4...
  • Page 2: Table Of Contents

    INSTALLATION GUIDE Corridor Lamp 4 Contents 1 Symbols — NICL4 Install Sheet ......................1 2 Description ............................2 3 Installation.............................3 4 Important Safety Information ......................4 5 Mounting............................5 Mount the NICL4 base onto a backbox..................5 Mount the Base without a Backbox ..................6 6 Connections and DIP Switch Settings ....................8...
  • Page 3: Symbols - Nicl4 Install Sheet

    Caution: Use extreme caution and follow instructions carefully. Caution: Bright LEDs behind translucent dome cover. High brightness light is produced by the LED boards that are placed onto the NICL4 circuit board. Do not stare into the light when the translucent dome cover is removed.
  • Page 4: Description

    Corridor Lamp 4 Description The Corridor Lamp (NICL4) is controlled by the room controller (NIRC4 only). Each room bus of the room controller (NIRC4) can support up to four NICL4 corridor lamps. The NICL4 corridor lamp supports up to 4 LED boards (NILD2, NILD4–RGB) behind a translucent dome cover.
  • Page 5: Installation

    Installation Installation The NICL4 has an IP40 ingress protection. The areas in which NICL4s are to be installed must be clean, dry, and weatherproof. The walls on which devices are to be installed should be finished (painted, wall papered, etc.) before the devices are installed. It is important to have the appropriate length of free cable available at every location where the NICL4 is to be installed.
  • Page 6: Important Safety Information

    The Corridor Lamp 4 (NICL4) Installation Instructions contain important instructions for use during installa- tion and maintenance of the NICL4. To ensure a safe working environment during the installation and operation of the NICL4, the following safety symbols appear throughout this document to indicate dangerous conditions and important safety instructions.
  • Page 7: Mounting

    Mounting Mounting The base of the NICL4 mounts to backboxes using an array of holes that allow for mounting on various EU and North American-style backboxes. In areas where no backboxes are available, the base can be mounted directly onto flat wall surfaces.
  • Page 8: Mount The Base Without A Backbox

    The cables should enter through the knockout holes in the base of the NICL4. Do not distort or twist the base when mounting it to a wall. If the base is distorted, the NICL4 dome cover will not fit properly and may fall off.
  • Page 9 Place the base (with the knockouts removed) over the holes, insert the screws, and then tighten. Pull the cables through the knockout holes and follow the directions in the following sections. Caution: The NICL4 must be mounted in a way that the module is firmly attached to the background.
  • Page 10: Connections And Dip Switch Settings

    Before attaching the PCB to its base, make all wire connections and DIP switch settings. Be sure that required cables are properly connected. The following figures show the locations for each cable. Figure 2. NICL4 Circuit Board - Front Legend (1) LED lamp (NILD2, NILD4–RGB) connections...
  • Page 11 INSTALLATION GUIDE Corridor Lamp 4 Connections and DIP Switch Settings Figure 3. NICL4 Circuit Board - Back Legend (1) DIP switches for Corridor Lamp ID selection (2) Buzzer (3) RJ45 room bus connectors for connection to NIRC4 room controller and NU-series PDs via daisy chaining TD 93352EN / 25 January 2021 / Ver.
  • Page 12: Setting The Corridor Lamp Id

    DIP switch settings for corridor lamp ID selection To set a DIP switch: Set the DIP switches to the ID (0 to 3) chosen for the NICL4. Use the ID table above to determine the correct positions (ON or OFF) for the DIP switches.
  • Page 13: Terminating And Mounting The Room Bus Rj45 Connectors

    Terminating and Mounting the Room Bus RJ45 Connectors The NICL4 includes two active room bus RJ45 sockets. Crimp the RJ45 connector(s) to the room bus cable (s) using the Ethernet T-568B termination color scheme. The following figure shows the correct pinout for terminating the active room bus cables.
  • Page 14 INSTALLATION GUIDE Terminating and Mounting the Room Bus RJ45 Connectors Corridor Lamp 4 Figure 5. Room Bus Connections TD 93352EN / 25 January 2021 / Ver. A...
  • Page 15: Nildx Led Lamp Placement

    To place the NILDx LED board(s): Insert the LED boards into the NICL4. The pins on the LED lamp board are not in the centre of the board, therefore it is important to make sure that the LED lamp board lines up with the guide marks on the corridor lamp PCB when the pins are inserted.
  • Page 16 Ascom (Sweden) AB Grimbodalen 2 SE–417 49 Göteborg Sweden Phone +46 31 55 93 00 www.ascom.com...