Wiring Diagram
Hood Installation
1. Lift the hood into position and guide the electrical cable through the electrical cable clamp on the hood
2. Insert the 4 wood screws from the bottom and securely fasten
3. Secure the electrical cable in the cable clamp while allowing sufficient length in the hood to connect the field wires to the hood wires
4. Make the electrical connections using screw-on wire connectors. Attach the BLACK wires together and then the WHITE wires together and after
that, the GREEN or bare wire to the GREEN GROUNDING screw in the hood. Replace the wiring compartment cover
5. Attach ductwork and use duct tape to seal all joints
6. After turning all rangehood switches to the OFF position, turn the power ON and test your installation
MAINTENANCE & OPERATION
Aluminum Filter
For highest efficiency, this filter should be removed and cleaned
periodically. Soak the filter in hot water and mild soap or detergent.
Rinse thoroughly and repeat if necessary. The aluminum filter may
be cleaned in the dishwasher. Heavy grease buildup may not be
cleaned easily, thus the filter may need to be replaced.
Light Bulb
DO NOT use light bulbs that are brighter than 40W
Repair or Replacement Parts
WARNING Disconnect rangehood from the electrical power supply before servicing
All parts may be obtained from service centers authorized by ORTECH, or may be ordered directly from ORTECH.
When ordering parts, please specify the rangehood model number on the rating label, which is located on the inside of the rangehood.
info@ortechindustries.com
www.ortechindustries.com
Installing Ductwork
Your new rangehood will operate at the highest efficiency if the
number of elbows and the length of the duct are kept to a
minimum. The back draft damper flap attached to the damper
frame assembly, which is supplied with the hood, does not
impede airflow significantly. You may leave this in place even if
you install a wall or roof cap with another back draft damper.
CAUTION
All wiring installation must comply with local and national
electrical code regulations.
Charcoal Filter
Inspect this filter periodically. This filter cannot be cleaned and must
be replaced when it becomes saturated. Check with your local
retailer or dealer to purchase.
Exterior Surface
Wipe the rangehood exterior with a soft cloth and a mild detergent
suitable for painted surfaces. DO NOT use abrasive materials such as
steel wool pads or scouring powders.